PCA 8-60B 

 
The SOLARJACK PCA 8-60B PUMP CONTROLLERS are high quality, solid state, DC power 
converters designed as the interface between a SOLARJACK SDS series pump and the 
DC power source. This power source may be solar panels or batteries. The purpose 
of the controller is to maximize the total daily water output while providing 
protection for the pump as well as the power source.  
 
The unique features incorporated in each controller will protect your pumping 
system allowing it to provide you with many years of dependable, trouble free 
service. When used in a solar panel direct system it provides protection for the 
pump from over-voltage and over-current conditions or will provide current 
boosting in low sunlight conditions.  
 
This manual will show you how to make the connections for your particular system 
configuration.  
 
Additional options are also explained and the wiring diagrams are given.  
 

PCA 8-60B SPECIFICATIONS 

 

Input Voltage                        24-80V (Open Circuit)  
      (Four 

Panels 

in 

Series 

Max) 

 

Maximum Output Current               8 AMPS  
Maximum Surge Current                12 AMPS  
Maximum Output Power             

 480 Watts (60V @ 8A)  

 

FEATURES 

 

1.) Current Boosting for matching the load requirements of the pump.  
 
2.) Voltage Regulation of the PV array at its maximum power point.  
 
3.) Built in controller protection:  

A. Over-current circuit breaker  
B. Reverse polarity (10 Amp Max)  
C. Surge suppression  

 
4.) Weather tight cast aluminum enclosure with hinged door.  
 
5.) On/off switch.  
 
6.) Output current limiting.  
 
7.) Remote float switch circuit.  
 
8.) Low water cut-off circuit with adjustable set points.  
 
9.) High water cut-off circuit with adjustable set points.  
 
10.) Power in and power out indicator.  
 
11.) Pre-adjusted panel voltage settings from a DIP switch.  
 
12.) Output voltage adjustment control. (OPTIONAL)  

Содержание PCA 8-60B

Страница 1: ...PCA 8 60B SDS SUBMERISIBLE PUMP CONTROLLER USER S MANUAL...

Страница 2: ...you how to make the connections for your particular system configuration Additional options are also explained and the wiring diagrams are given PCA 8 60B SPECIFICATIONS Input Voltage 24 80V Open Circ...

Страница 3: ...DIP SWITCH 6 ON Low water cut off 1 LO LOW WATER LEVEL SENSOR turns the pump off Mount an E 1s electrode 2 above the ground sensor 2 HI HIGH WATER LEVEL SENSOR turns the pump on Mount an E 1s brass el...

Страница 4: ...oints available on this controller are as follows Switch No Used For Voltage Set Point 1 30 Volt Panel Direct 26 0 2 45 Volt Panel Direct 41 O 3 60 Volt Panel Direct 54 0 4 For Factory Use Only 5 Remo...

Страница 5: ...cross terminals 5 PV and 6 LD this will bypass the controller and will allow the pump to run panel direct Note You must have full or almost full sun for this test to be valid 3 Make sure the proper vo...

Страница 6: ...controller will not turn on See controller adjustment section 4 Check to see if the float switch if used is functioning properly Disconnect wires from terminals 3 4 to bypass float circuit 5 Make sure...

Страница 7: ...7 19 1999 7...

Страница 8: ...S POS SOLAR MODULE PRESET VOLTAGE SETTINGS 1 ON FOR 2 MODULES WIRED IN SERIES 30 VOLTS 2 ON FOR 3 MODULES WIRED IN SERIES 45 VOLTS 3 ON FOR 4 MODULES WIRED IN SERIES 60 VOLTS 4 FOR FACTORY USE ONLY RE...

Страница 9: ...7 19 1999 9 WELL ELECTRODE INSTALLATION...

Страница 10: ...7 19 1999 10...

Страница 11: ...7 19 1999 11...

Страница 12: ...7 19 1999 12...

Страница 13: ...r of the product voids all warranty Warranty limitations There are no express warranties except as listed above SOLARJACK shall have no responsibility for damage to property persons animals or other l...

Отзывы: