9
SOLARIS® SMART 54W™
DMX DATA LINK
A DMX 512 data link is required in order to control the fixture via DMX. The fixture has
3-pin XLR connectors for DMX data input and output. The number of daisy-chained fix
-
tures is limited by the number of DMX channels required by the fixtures in relation to the
maximum 512 channels available in one DMX universe. Note that if independent control
of a fixture is required, it must have its own DMX channels.
Fixtures that are required to behave identically can share the same DMX address and
channels. To add more fixtures or groups of fixtures when the above limit is reached, add
a DMX universe and another daisy-chained link.
CONNECTING AND USING DMX DATA LINK
To connect the fixture to data:
1. Connect the DMX data output from the controller to the first fixture’s male XLR
DMX input connector.
2. Connect the first fixture’s DMX output to the DMX input of the next fixture and contin
-
ue connecting fixtures output to input.
Содержание smart 54w
Страница 1: ...USER MANUAL...