User Manual - Ground Mount Solar Hot Water System - August 2017
Save A Service Call - Solargain Basic Troubleshooting Guide
PROBLEM
SOURCE
EXPLANATION
Water not as hot as
previous hot water system
Tempering Valve installed
A tempering valve must be installed on every solar hot water system.
Tempering valves will mix water down to 50°C.
No Hot Water
Electric or gas booster
is not turned on or not
configured correctly
Electric booster should be set to at least 60°C. Ensure circuit breaker is
switched on. Ensure power is switched on to gas booster. Ensure mains
gas supply hasn’t been isolated.
Overflow pipe is dripping
Pressure Temperature
Relief Valve (PTR) /
Expansion Control Valve
(ECV) where applicable.
An 850kPa and 99°C PTR valve is used on the Solargain water tank,
which is located on the side of the water tank and is essential for its safe
operation. The PTR valve is designed to allow 3-5% of total tank volume
to discharge during heating to allow for hot water expansion.
Water pressure is slightly
lower than previous hot
water system
Pressure Reduction Valve
(PRV)
A pressure reduction valve has been installed to limit the inlet pressure
to your new Solargain Water Heater. This device regulates the incoming
pressure & increases life of the cylinder. This device will also protect your
cylinder if the mains pressure is increased by the local water authority.