13 Weatherman function
14.1 Required activities - overview
The implementation responsibility of the maintenance
activities is defined according to type and extent (sys-
tem operator
SO
or qualified personnel
QP
).
Activity
Interval
AB FP
Empty ash container
upon noti-
fication
message
X
Perform boiler cleaning
–
Check the stainless steel
combustion grate for wear
–
Check the stainless steel
combustion grate support
–
Remove ash from the com-
bustion chamber
monthly
[1]
[2]
X
Check system pressure
monthly
X
Clean flue gas pipe
yearly
X
Check safety valve
yearly
X
Replace pellet suction turbine
After
approx.
800 ope-
rating
hours
X
Maintenance by qualified per-
sonnel
yearly
X
Perform emissions mea-
surement
as per
regional
regulations
X
[1] Indication is valid for average consumption values; Adjust the
interval according to your own requirements.
[2] In the boiler control a message can be set (to be carried out by
qualified personnel), with a reminder to perform a boiler clea-
ning.
i
You can use the function
E-Mail Message
to be informed about an upcoming empty-
ing of the ash container (see
Alarm selection
button)
14.1.1 Empty ash container
Empty the ash container when the message on the boi-
ler control display appears. In the course of emptying
the ash container, a boiler cleaning
can also be
performed.
Information on required emptying of the ash box:
Fig. 2-52
►
Wait until the burner switches off (the burner still
fulfils its heating requirements, i.e. this can take
longer).
►
Open both lateral turnbuckles on the ash box,
remove the ash box, empty it and reattach it.
DANGER
- risk of fire due to hot ash self-igni-
ting. Only store removed ash in metal con-
tainers with a lid.
►
Confirm the information message on the display
with OK
►
Press the
Ash box emptied
2
button (in the selec-
tion menu,ash box button).
Fig. 2-53
Ä
The counter for the ash box fill level is reset to
zero.
Note: Press button
3
to open the
Boiler cleaning sta-
tistics
screen (shows the time of the last 5 boiler clea-
nings).
Operation manual
pellettop