                 MAN-01-00028-1.1 

 

 

7

  Use the three right-most buttons inside the SolarEdge 

device (the 

UP-1

Down-2

 and 

Enter-3

 buttons), shown 

above, to type in the following default password: 

12312312

.  

For firmware versions above 2.250, continue to step 

12

For earlier versions, complete steps 

9

 through 

11

 

below. 

8

  Scroll down to the 

Communication

 submenu and select it. 

Select the 

Bus

 submenu. Scroll down and select 

RS485 

Slave

. The SolarEdge device performs a reset immediately 

after the selection is made. 

Bus Submenu: 

 

Z  i  g  b  e  e    P  2  P       

       

 

Z  i  g  b  e  e    M  P         

       

 

R  S  4  8  5    M  a  s  t  e  r   

       

R  S  4  8  5    S  l  a  v  e     

       

 

N  o  n  e                   

       

10 

Repeat steps 

6

 through 

8

 above to enter Setup mode. 

11 

Select the 

Server

 submenu, scroll down to the 

RS485

 

option and select it. The SolarEdge device performs a reset 
immediately after the selection is made. 

Communication Submenu: 

>  S  e  r  v  e  r  <  L  A  N  >       

 

 

  B  u  s  <  Z  i  g  B  e  e  >       

 

 

  L  A  N    C  o  n  f             

 

 

  R  S  4  8  5    C  o  n  f  <  S  >   

 

 

  Z  i  g  b  e  e    C  o  n  f  <  S  >   

 

  R  S  2  3  2    C  o  n  f         

 

 

  M  o  d  b  u  s    C  o  n  f       

 

 

This concludes the setting of the slave SolarEdge devices 
for firmware versions earlier than 2.250. 

Follow steps 

12

 through 

16

 for firmware versions 

above 2.250. 

12 

Select the 

Server

 submenu, scroll down to the 

RS485

 

option and select it.  

Communication Submenu: 

>  S  e  r  v  e  r  <  L  A  N  >           

  L  A  N    C  o  n  f                 
  R  S  4  8  5  -  1    C  o  n  f  <  S  >   
  R  S  4  8  5  -  2    C  o  n  f  <  S  >   
  Z  I  G  B  E  E    C  o  n  f  <  S  >     
  R  S  2  3  2    C  o  n  f             

13

 

Select the 

RS485-X Conf 

(the port that is physically 

connected to the daisy chain)

 

submenu option.  

14 

Select the 

Device Type

 submenu and set it to 

SolarEdge

RS485-X Submenu: 

> D  e  v  i  c  e    T  y  p  e  <  S  E     > 

 

  P  r  o  t  o  c  o  l  <  M    >       

 

 

  D  e  v  i  c  e    I  D  <  1  >       

 

 

  S  l  a  v  e    D  e  t  e  c  t       

 

 

15 

Select the 

Protocol

 submenu and set it to 

Slave

.

 

16 

Press the 

ESC

 button repeatedly to exit the Setup menu or 

wait for the device to automatically exit Setup mode if no 
buttons are pressed for more than two minutes. 

This concludes the slave device configuration using the 

LCD button for firmware version 2.250 and above. 

---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 

For the master (main) SolarEdge device, perform the 
following steps: 

Repeat steps 

2

 through 

8

, as described above in the Slave 

Configuration section to enter Setup mode. 

For firmware versions above 2.250, continue to step 

7

For earlier versions, complete steps 

2

 through 

6

 

below. 

Select the 

Bus

 submenu. Scroll down and select 

RS485 

Master

. The SolarEdge device performs a reset 

immediately after the selection is made. 

Bus Submenu: 

  Z  i  g  b  e  e    P  2  P           

   

  Z  i  g  b  e  e    M  P             

   

>  R  S  4  8  5    M  a  s  t  e  r       

   

  R  S  4  8  5    S  l  a  v  e         

   

  N  o  n  e                       

   

Repeat steps 

6

 through 

8

 above in the Slave 

Configuration section to enter Setup mode.

 

Scroll down to the 

RS485 Conf

 submenu and select it. 

Select the 

Master Set

 option and select 

Enable

. The 

SolarEdge device performs a reset immediately after the 
selection is made. 

Communication Submenu: 

  S  e  r  v  e  r  <  L  A  N  >       

 

 

  B  u  s  <  Z  i  g  B  e  e  >       

 

 

  L  A  N    C  o  n  f             

 

 

>  R  S  4  8  5    C  o  n  f  <  S  >   

 

 

  Z  i  g  b  e  e    C  o  n  f  <  S  >   

 

  R  S  2  3  2    C  o  n  f         

 

 

  M  o  d  b  u  s    C  o  n  f       

 

 

Repeat steps 

6

 through 

8

 as described above in the 

Slave Configuration section to enter Setup mode.

 

Scroll down to the 

RS485 Conf

 submenu and select 

it.  

Communication Submenu: 

  S  e  r  v  e  r  <  L  A  N  >       

 

 

  B  u  s  <  Z  i  g  B  e  e  >       

 

 

  L  A  N    C  o  n  f             

 

 

>  R  S  4  8  5    C  o  n  f  <  S  >   

 

 

  Z  i  g  b  e  e    C  o  n  f  <  S  >   

 

  R  S  2  3  2    C  o  n  f         

 

 

  M  o  d  b  u  s    C  o  n  f       

 

 

Содержание GenPro 20e SQB

Страница 1: ...the AC power off and wait five minutes 5 Open the SolarEdge device cover as instructed in the device manual 6 Open gland 1 located on the bottom of the SolarEdge device as shown in Figure 2 Figure 2 shows the SMI as an example The procedure is similar for the inverter Figure 2 Cable Gland Location on SMI The smallest hole is for RS232 cable insertion The SolarEdge device glands come presealed from...

Страница 2: ...ce cover Four buttons for controlling the LCD panel menus are then accessible as shown below Esc Goes to the beginning of the currently entered parameter or to the previous menu Up 1 Goes up one option in a menu Down 2 Goes down one option in a menu Enter 3 Confirms the entry or selection of a parameter Figure 4 LCD Panel Menu Buttons 5 Press the Enter button for at least five seconds The followin...

Страница 3: ... Conf submenu select Set Password and then enter the password if required by the GSM service provider Press the Enter button for a long press to apply or press the ESC button for a long press to abort Verifying the Connection To verify the connection 1 Wait for the SolarEdge device to connect to the SolarEdge Monitoring Server This may take up to two minutes 2 Verify that the LCD panel displays a ...

Страница 4: ...the remaining steps in this procedure Figure 6 RS485 Termination Switch 2 Verify that the SolarEdge device s ON OFF switch is OFF 3 Press the LCD Light button once to turn ON the backlight WARNING If the SolarEdge device worked properly before this action the adjacent message is displayed This message is displayed until the DC is safe The default safety voltage is 50 V Do not open the cover or ope...

Страница 5: ...SolarEdge RS485 X Submenu D e v i c e T y p e S E P r o t o c o l M D e v i c e I D 1 S l a v e D e t e c t 15 Select the Protocol submenu and set it to Slave 16 Press the ESC button repeatedly to exit the Setup menu or wait for the device to automatically exit Setup mode if no buttons are pressed for more than two minutes This concludes the slave device configuration using the LCD button for firm...

Страница 6: ... Yes A Detecting Slaves message is shown during the detection process The master should report the correct number of slaves on the LCD screen If it does not verify the connections and terminations 11 Press the ESC button repeatedly to exit the Setup menu This concludes the multi SolarEdge device setup using the user buttons Support and Contact Information If you have technical questions concerning...

Отзывы: