5. Connect
the
load
wires
to
the
terminal
blocks
(see
,
6
):
w
l
230 Vac (connections 1,2 ) - to Line and Neutral. The connections are interchangeable.
l
Dry-contact 250V / 13A maximum (connections 3, 5) - to a dedicated voltage source from the
appliance (see
), or an external power supply according to the input control specifications
of the appliance (see
).
l
Managed load (connections 4,6) -to the appliance input control
The two switches have a single control. That is, either both are closed or both are opened.
Figure 5: Connecting to appliance with internal
voltage source (Vout)
Figure 6: Connecting to appliance with external
voltage source
6. Place the cable bracket over the cables and fasten using the screws.
7. Attach the cover to the device and fasten the screws.
Configuration
NOTE
Verify that the inverter is connected to the monitoring portal (refer to the
Inverter Installation Guide
for
details on setting up communication).
To associate the device with the ZigBee network:
1. Enter the inverter Setup mode as described in the
Inverter Installation Guide
.
2. Select
Communication
è
ZigBee Conf.
.
SolarEdge
Dry-Contact
switch
Installation
Guide
4
Configuration
3. Select:
l
Device Type
è
HA
(Home Automation)
l
Protocol
è
HAM
(Home Automation)
D e v i c e
T y p e < H A >
P r o t o c o l < H A M >
P A N
I D
S c a n
C h a n n e l
L o a d
Z B
D e f a u l t s