background image

Allen screwdriver for M5/M6/M8 screw types

Standard flat-head screwdrivers set

Non-contact voltage detector 

Cordless drill (with a torque clutch) or screwdriver and bits suitable for the surface 

on which the inverter and optimizers will be installed. Use of an impact driver is 

not 

allowed.

Mounting hardware  (stainless bolts, nuts, and washers) for attaching:

the mounting brackets to the mounting surface 

the power optimizer to the racking 

MC4 crimper

Wire cutters 

Wire strippers 

Voltmeter

For installing the communication options, you may also need the following:

For Ethernet:

CAT6 twisted pair Ethernet cable with RJ45 connector

If using a CAT6 cable spool: RJ45 plug and RJ45 crimper

For RS485:

Four- or six-wire shielded twisted pair cable

Watchmaker precision screwdriver set 

Inverter Transport and Storage

Transport the inverter in its original packaging, facing up and without exposing it to 

unnecessary shocks. If the original package is no longer available, use a similar box that 

can withstand the weight of the inverter (refer to the inverter weight in the specification 

datasheet provided with the unit), has a handle system and can be closed fully.

Store the inverter in a dry place where ambient temperatures are -13°F to 140°F / 

-25°C to +60°C.

Chapter 1: Introducing the SolarEdge Power Harvesting System     

11

Three Phase System MAN-01-00505-1.5

Содержание Delta E30K-RW00IBNJ4

Страница 1: ...Installation Guide Three Phase System with SetApp Configuration For Europe and APAC Version 1 5...

Страница 2: ...l at any time and without notice You may refer to the SolarEdge web site www solaredge com for the most updated version All company and brand products and service names are trademarks or registered tr...

Страница 3: ...n If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on you are encouraged to try to correct the interference b...

Страница 4: ...onnecting Power Optimizers in Strings on page 17 Added the requirement for a special bracket when installing close to the shoreline in Mounting the Inverter on page 24 For inverter clearance added a l...

Страница 5: ...gs 17 Step 4 Verifying Proper Power Optimizer Connection 18 Chapter 3 Installing the Inverter 19 Inverter Package Contents 19 Identifying the Inverter 19 Inverter Interfaces 20 Mounting the Inverter 2...

Страница 6: ...55 Connecting the AC Grid to the Inverter 56 Connecting the Strings to the DC Safety Unit 57 Appendix D SafeDC 59 Appendix E External Fan Maintenance and Replacement 60 Fan Maintenance 60 External Fan...

Страница 7: ...ss of life Do not proceed beyond a warning note until the indicated conditions are fully understood and met CAUTION Denotes a hazard It calls attention to a procedure that if not correctly performed o...

Страница 8: ...the inverter and repairing or testing under power must be performed only by qualified service personnel familiar with this inverter WARNING Do not touch the PV panels or any rail system connected whe...

Страница 9: ...on maintenance and support are the responsibility of the installer Damage to the inverter due to incorrect interlock installation or use of an interlock that is incompatible with the SolarEdge system...

Страница 10: ...Maximum Power Point Tracking MPPT at the module level The power optimizers regulate the string voltage at a constant level regardless of string length and environmental conditions The power optimizer...

Страница 11: ...the technical and financial performance of one or more SolarEdge sites It provides past and present information on the system performance both at the system and module levels Installation Procedure T...

Страница 12: ...t CAT6 twisted pair Ethernet cable with RJ45 connector If using a CAT6 cable spool RJ45 plug and RJ45 crimper For RS485 Four or six wire shielded twisted pair cable Watchmaker precision screwdriver se...

Страница 13: ...rged in water CAUTION This unit must be operated according to the operating specifications provided with the unit CAUTION Cutting the power optimizer input or output cable connector is prohibited and...

Страница 14: ...ation refer to https www solaredge com sites default files optimizer input connector compatibility pdf IMPORTANT SAFETY FEATURE Modules with SolarEdge power optimizers are safe They carry only a low s...

Страница 15: ...les Frame mounted power optimizers are mounted directly on the module frame regardless of racking system rail less or with rails For installation of frame mounted power optimizers refer to http www so...

Страница 16: ...power optimizers P860 and M1600 power optimizers Figure 2 Power optimizer clearance When installing modules in a confined space for example if installing Building integrated photovoltaic BIPV modules...

Страница 17: ...que requirements Do not use impact drivers for mounting the power optimizer Do not drill through the power optimizer or through the mounting holes 3 Attach each power optimizer to the rack using M6 1...

Страница 18: ...econd power optimizer 2 To minimize electromagnetic interference EMI make sure to minimize the distance between the positive and negative DC cables For detailed instructions see https www solaredge co...

Страница 19: ...ditional systems For more information about the SolarEdge system s string voltage and current refer to the VOC and ISC in SolarEdge Systems Technical Note available on the SolarEdge website at https w...

Страница 20: ...ted in the same conduit 1000V rated cables must be used Inverter Package Contents One inverter with DC Safety Unit if applicable One mounting bracket Two Allen screws for fastening the inverter to the...

Страница 21: ...ernal gauge M32 15 21mm diameter for connection to the grid DC input MC4 connector for connection of the PV installation AC and DC conduit entries Connection points of the Connection Unit Two communic...

Страница 22: ...onds or error type indications if exist for 5 seconds Activates the Wi Fi access point for connecting to the SetApp While the switch is in P all LEDs are ON When the switch is released all LEDs turn O...

Страница 23: ...itch Position LED Color Comment Red Green Blue Power optimizers not paired ON 1 OFF Blinking S_OK ON No S_OK OFF S_OK ON communication with the monitoring platform is established Pairing Blinking Blin...

Страница 24: ...witch Position LED Color Comment Red Green Blue Percentage of AC Production 0 ON 1 OFF OFF OFF This indicates power production as percentage of rated peak AC output power Percentage of AC Production 0...

Страница 25: ...ase inverter models can be installed horizontally above 10 tilt as well as vertically and at any tilt over 10 up to 90 For information and instructions for horizontal mounting refer to http www solare...

Страница 26: ...proper heat dissipation follow the guidelines specified in Application Note Clearance Guidelines https www solaredge com sites default files se clearance guidelines for multiple inverter mounting pdf...

Страница 27: ...on the bracket see Figure 9 Lift the inverter from the sides or hold it at the top and bottom of the inverter to lift the unit into place Do not lift holding the Connection UnitDC Safety Unit as it ma...

Страница 28: ...racket is firmly attached to the mounting surface Figure 10 DC Safety Unit bracket 8 Insert the two supplied screws through the outer heat sink fin on both sides of the inverter and into the bracket s...

Страница 29: ...atibility at http www solaredge com sites default files se_inverters_ supported_countries pdf installing without confirmation may void the inverter warranty For more wiring information refer to the So...

Страница 30: ...and see WARNING Turn OFF the AC before connecting wires to the AC terminals If connecting equipment grounding wire connect it before connecting the AC Line and Neutral wires 5 For SE25K SE27 6K and SE...

Страница 31: ...sily 9 Tighten the AC cable gland with a torque of 2 8 3 3 N m 2 0 2 4 lb ft 10 Verify that there are no unconnected wires to the inverter and that the unused terminal screws are tightened Connecting...

Страница 32: ...l the residual current device RCD in accordance with the applicable local standards and directives SolarEdge recommends using a type A RCD The recommended RCD value is 100 mA or 300 mA unless a lower...

Страница 33: ...gher than the allowed current but because the internal inverter RCD automatically resets when the residual currents are low it saves the manual reset For detailed information refer to the RCD Selectio...

Страница 34: ...tion is created between the mobile device and the inverter and the system firmware is upgraded Before activation Download register first time only and log in to SetApp on your mobile device Verify tha...

Страница 35: ...uit breaker on the main distribution panel Open SetApp and follow the on screen instructions scan the inverter QR code move the ON OFF P switch to P position for 2 seconds and release The mobile devic...

Страница 36: ...is reached the inverter enters Production mode and produces power The steadily lit green inverter LED indicates this mode 4 Tap OK to return to the Commissioning menu Communication Communication setti...

Страница 37: ...sions are installed on each inverter 2 Select Status and verify that inverter is operating and producing power 3 Verify that additional configurations were properly set by viewing the relevant Status...

Страница 38: ...g platform will show the logical layout indicating which power optimizers are connected to which inverter but will not show strings or the physical location of power optimizers The monitoring platform...

Страница 39: ...al Layout Editor 1 If you are a registered installer access the monitoring platform site creation page at https monitoring solaredge com solaredge web p home createSites If you have not yet signed up...

Страница 40: ...le is turned OFF and the AC is turned OFF When configuring the communication parameters while the inverter cover is removed make sure that the ON OFF P switch and the switch of the DC Safety Unit if a...

Страница 41: ...tion to connect one or several devices depending on the data plan used to the monitoring platform The Cellular Plug in is provided with a user manual which should be reviewed prior to connection Refer...

Страница 42: ...meter 1 PG16 One small External antenna cable 2 4 mm Two large Ethernet connection CAT6 Cellular ZigBee or Wi Fi 4 5 7 mm 2 PG13 5 All three RS485 power reduction 2 5 5 mm Figure 15 Communication Glan...

Страница 43: ...afety Unit Cover if applicable 1 Turn OFF the AC breaker of the distribution panel and the safety switch if applicable 2 Open the DC Safety Unit cover Release the four Allen screws and remove the cove...

Страница 44: ...emove the inverter cover 2 Open the communication gland 1 CAUTION The gland includes a rubber waterproof fitting which should be used to ensure proper sealing 3 Remove the plastic seal from one of the...

Страница 45: ...eserved Figure 19 Standard cable wiring 6 Use a pre crimped cable to connect via gland 1 to the RJ45 plug on the inverter s communication board or if using a spool of cable connect as follows a Insert...

Страница 46: ...the monitoring platform 9 The inverter is configured by default to LAN If reconfiguration is required a Make sure the ON OFF P switch is OFF b Turn ON the AC to the inverter by turning ON the circuit...

Страница 47: ...surge protection devices For details refer to https www solaredge com sites default files lightning_ surge_protection pdf If grounded metal conduits are used for routing the communication wires a ligh...

Страница 48: ...wire twisted pair cable for this connection You can use any color wire for each of the A B and G connections as long as The same color wire is used for all A pins the same color for all B pins and th...

Страница 49: ...The switch is located on the communication board and is marked SW7SW1 Figure 23 RS485 termination switch NOTE Only the first and last SolarEdge devices in the chain should be terminated The other inv...

Страница 50: ...5 1 Follower Detect The system starts automatic detection of the follower inverters connected to the leader inverter The inverter should report the correct number of followers If it does not verify th...

Страница 51: ...error types use the methods described below To identify the error type using the inverter LEDs 1 Move the ON OFF P switch to P position for 2 seconds and release it 2 Observe the LED lights and use t...

Страница 52: ...ight connection No Internet connection Ping to google com failed Connect a laptop and check for internet connection If internet access is unavailable contact your IT admin or your internet provider Fo...

Страница 53: ...ble Cause and Corrective Action Pairing failed Power optimizers are shaded If you connected the inverter to the monitoring platform retry pairing remotely during sunlight Make sure to leave the invert...

Страница 54: ...ected in the string and that no module outputs are connected without a power optimizer If the problem persists proceed to the next step Power optimizer s malfunction 1 Disconnect the wires connecting...

Страница 55: ...endix B Mechanical Specifications Figure 24 Inverter with bracket front side and rear views Figure 25 Inverter mounting bracket Three Phase System MAN 01 00505 1 5 54 Appendix B Mechanical Specificati...

Страница 56: ...DC Safety Unit includes Mechanical DC switch 2 pole disconnection DC surge protection SPD Type II DC fuses plus minus optional This appendix describes connections to DC Safety Unit with or without fus...

Страница 57: ...ION When removing the cover make sure not to damage internal components SolarEdge will not be held responsible for any components damaged as a result of incautious cover removal 3 Loosen the screws on...

Страница 58: ...re tightly attached to the DIN rail NOTE If power control is enabled it is important to respect the order of grid lines connection to the inverter A 120deg phase difference should be kept between L1 t...

Страница 59: ...lly clamped Figure 30 Spring clamp terminals For DC terminals with fuses Insert the wires into the side openings Fasten the screws at the top of the fuses Apply torque of 3 4 N M 30 lb in Figure 31 DC...

Страница 60: ...o disconnect DC power 1 1 Move the inverter P ON OFF switch to OFF 0 2 Disconnect the AC to the inverter by turning OFF the circuit breakers on the distribution panel WARNING SafeDC complies with IEC6...

Страница 61: ...t section External Fan Replacement 1 Turn OFF the inverter ON OFF P switch and wait until the green LED is blinking indicating that the DC voltage is safe 50V or wait five minutes before continuing to...

Страница 62: ...e new fan 7 Close the fan door and fasten the cover screws 8 After powering up the inverter open SetApp and check that the Fan status is OK under Commissioning Status Appendix E External Fan Maintenan...

Страница 63: ...as it may harm the inverter sealing and void the warranty Replacing an Inverter 1 Turn OFF the inverter ON OFF P switch and wait until the green LED is blinking indicating that the DC voltage is safe...

Страница 64: ...sioning and Configuring the System on page 33 11 Close the DC Safety Unit cover if applicable and the inverter cover Replacing the DC Safety Unit Removing the DC Safety Unit 1 Turn OFF the inverter ON...

Страница 65: ...DC wires extending from the switch conduits 3 Attach the DC Safety Unit with its bracket to the wall and slightly close the screws Do not over tighten 4 Securely screw the two conduit nuts onto the c...

Страница 66: ...m 0 88 1 1 lb ft 5 Verify that there are no unconnected wires at the output of the DC Safety Unit and that any unused terminal screws are tightened 6 Connect the DC and AC wires to the DC Safety Unit...

Страница 67: ...r optimizers 5 Perform pairing and other procedures described in Activating Commissioning and Configuring the System on page 33 on all inverters to which power optimizers were added or from which powe...

Страница 68: ...power grid The following figure illustrates a typical transformer and commercial three phase inverter installation topology Figure 38 Typical transformer and commercial three phase inverter installati...

Страница 69: ...t to the various de rating considerations NOTE Transformer procurement installation maintenance and support are the responsibility of the installer Damage to the inverter due to incorrect transformer...

Страница 70: ...than the maximum output current of the inverter consider selecting a circuit breaker that is designed for a higher rated current or reducing the temperature de rating effect by increasing the distanc...

Страница 71: ...Current per Phase Recommended Circuit Breaker Three Phase Inverter SE12 5K 20A 25A SE15K 23A 32A SE16K 25 5A 32A SE17K 26A 32A SE25K 38A 50A SE27 6K 40A 50A SE30K 43 5A 63A SE33 3K 48 25A 63A Three P...

Страница 72: ...us Output Current per Phase Recommended Circuit Breaker Three Phase Inverter with Synergy Technology SE66 6K 80A 100A SE100K 120A 150A Appendix G Determining the Circuit Breaker Size 71 Three Phase Sy...

Страница 73: ...2 L3 N TN TT AC output voltage line to line line to neutral nominal 380 220 400 230 Vac AC output voltage range 184 264 5 Vac AC frequency 50 60 5 Hz Maximum continuous output current per phase 5 6 5...

Страница 74: ...ion 3 Protective class Class I Utility monitoring islanding protection configurable Power Factor country configurable thresholds Yes Overvoltage category III Input Maximum DC power Module STC 4050 540...

Страница 75: ...tection Yes Ground fault isolation detection 700k Sensitivity Overvoltage category II Maximum inverter efficiency 98 European weighted efficiency 96 7 97 3 97 3 97 3 97 4 97 6 97 5 97 6 97 7 Night tim...

Страница 76: ...Grid connection standards 4 VDE 0126 1 1 VDE AR N 4105 AS 4777 G83 G59 1 For specifications of communication options refer to Datasheets Communications category in the Downloads page http www solaredg...

Страница 77: ...densing 95 Cooling Fan user replaceable Noise typical 50 3 dBA Protection rating Environmental category IP65 Outdoor and indoor 1 You can connect strings in parallel to a single input as long as the c...

Страница 78: ...3300 VA Maximum AC power output 15000 16000 17000 250006 27600 33300 VA AC Output Line Connections 3 phase 4 wire PE L1 L2 L3 N TN TT AC output voltage line to line line to neutral nominal 380 220 400...

Страница 79: ...r factor range 1 adjustable from 0 9 to 0 9 1 adjustable from 0 8 to 0 8 1 Total harmonic distortion 3 Protective class Class I Utility monitoring islanding protection configurable Power Factor countr...

Страница 80: ...es Supported communication interfaces RS485 Ethernet Cellular Optional Inverter commissioning With the SetApp mobile application using built in Wi Fi access point for local connection RS485 Surge Prot...

Страница 81: ...ications AC output Gland Diameter Wire Cross Section 15 21 mm Solid wire 2 5 16 mm2 Stranded wire 2 5 10 mm2 18 25mm Solid wire 2 5 16 mm2 Stranded wire 2 5 10 mm2 DC input 4 2 MC4 pairs 3 MC4 pairs 1...

Страница 82: ...rature range 1 40 60 C Operating humidity non condensing 95 Cooling Fan user replaceable Noise typical 50 55 dBA Protection rating Environmental category IP65 Outdoor and indoor Maximum altitude 2000...

Страница 83: ...The error indicated on the product SetApp mobile application or on the monitoring platform or by the LEDs if there is such an indication System configuration information including the type and number...

Страница 84: ......

Отзывы: