SOLARA Zero Clearance MQZDV3318 Скачать руководство пользователя страница 21

21

General Glass Information

Glass Cleaning

It will be necessary to clean the glass periodically. During start-up, con-
densation, which is normal, forms on the inside of the glass and causes
dust, lint etc. to cling to the glass surface.  Also, initial paint curing can
deposit a slight film on the glass.  It is therefore recommended that ini-
tially the glass be cleaned two or three times with non-abrasive com-
mon household glass cleansers and warm water. After that, the glass
should be cleaned two or three times a season depending on the circum-
stances.

Cautions and Warnings

• Do not clean when the glass is hot.

• The use of substitute glass will void all product warranties.

• Care must be taken to avoid breakage of the glass.

• Do not operate this fireplace without the glass front or with a broken

glass front.

• Do not strike or abuse glass.

Glass Replacement

The glass should be replaced by a qualified person.

REPLACEMENT GLASS FOR BOTH DIRECT VENT UNITS

These models can use either tempered glass or Robax ceramic or coat-
ed Neaoceram glass.  Must be 5mm thick.

To replace glass, clean all materials from door frame.  Scrape off old
silicone down to metal.  Using a high heat silicone (temperature-resis-
tant to 500°F (260°C) apply a  continuous bead of approximately 1/32”
to all four sides of frame and insert glass with new gasket.  Frame
should be on flat surface, with a small amount of weight pressing glass
into silicone. Let dry approximately 15 to 20 minutes.  The door can be
re-installed by reversing Steps 1 & 2.  Use caution when removing bro-
ken glass, wear gloves.

Removal of the Glass Door

1. Unlatch the two latches located behind the upper grill.

2. To remove, pull frame forward and lift from bottom door retainer.

Gas Line Installation

This gas appliance should be installed by a qualified installer in accordance with
local building codes and with current CAN/CGA - B149.1 or .2 installation codes for
Gas Burning appliances and equipment in Canada and the National Fuel Gas Code
ANSI Z223 in the U.S.A.

1. The gas pipeline can be brought in through either the right or the left side of the

appliance. A knockout is provided at either location to allow for the gas pipe
installation and testing of any gas connection.

2. The gas control inlet is 3/8” NPT. Typical installation layout for rigid pipe is

shown at right.

3. When using 

copper

or 

flex connector

, use only approved fittings. Always pro-

vide a union so that gas line can be easily disconnected for burner or fan servic-
ing. See gas specification for pressure details and ratings.

4. When a vertical section of gas pipe is required for the installation, a condensa-

tion trap is needed. See CAN/CGA-B149.1 or .2 for code details.

5. For natural gas, a minimum of 3/8” iron pipe with gas minimum pressure of 4.5”

w.c. must be used for supply from the gas meter. Consult with the local gas utili-
ty if any questions arise concerning pipe sizes.

Gas Specifications

Models

MQZDV3318N

MQZDV3318LP

MQZDV3622N

MQZDV3622LP

Fuel

Natural

Propane

Natural

Propane

Gas Control

Millivolt adjustable

Millivolt adjustable

Millivolt adjustable

Millivolt adjustable

Input
Maximum

19,000 BTU

18,000 BTU

21,000 BTU

21,000 BTU

Low

12,100 BTU Low

11,900 BTU

14,200 BTU

16,200 BTU

Orifice Size

#45

#55

#43

#54

(0 - 4500 ft)

Air Shutter

3/16” Open

9/32” Open

3/16” Open

3/8” Open

Gas Inlet Size

S.I.T. 820 Nova, 3/8” NPT

Gas Supply Pressure

Minimum

Normal

Maximum

Natural Gas

5.5”

7”

9”

Liquid Propane

11”

11”

12”

Manifold Pressure

Natural Gas

Liquid Propane

Manifold Pressure High

3.5 IN. W.C./.87 KPa

10 IN. W.C./2.61 KPa

Manifold Pressure Low

1.6 IN. W.C./.40 KPa

6.3 IN. W.C./1.57 KPa

6. A 1/8” NPT plugged tappings are accessi-

ble for test gauge connection both on the
inlet and outlet of the gas valve.

7. Turn the gas supply ON and check for

leaks. DO NOT USE OPEN FLAME FOR
THIS PURPOSE. Use an approved leak
testing solution.

8. The appliance and its individual shutoff

valve must be disconnected from the gas
supply piping system during any pressure
testing of that system at test pressures in
excess of 1/2 PSIG (3.5 KPa).

9. The appliance must be isolated from the

gas supply piping system by closing its
individual shutoff valve during any pres-
sure testing of the gas supply piping system
at test pressures equal to or less than 1/2
PSIG (3.5 KPa).

Note: The gas line connection may be made of 1/2” rigid pipe or an approved
flex connector. Since some municipalities have additional local codes, it is
always best to consult your local authorities and the current CAN/CGA - B149.1
or .2 installation code in Canada or the National Fuel Gas code ANSI Z223.1 in
the U.S.A.

Important: 

Always check for gas leaks with a soap and water

solution. Do not use open flame for leak testing.

For the state of Massachusetts a 

T-handle gas shut-off valve

must be used on a gas appliance.

This T-handle gas shut-off valve must be listed and approved by the state of Massachusetts.  

This is in reference to the state of Massachusetts state code CMR238.

Содержание Zero Clearance MQZDV3318

Страница 1: ...vice or maintenance can cause property damage personal injury or loss of life Refer to this manual Installation and service must be performed by a qualified installer service agency or the gas supplie...

Страница 2: ...wn between each Be aware during log and firebox paint curing that a white deposit may be developing on the inside of the glass doors It is important to remove this white deposit from the glass doors w...

Страница 3: ...es Specifications 16 Dimensions Installation of Wall Mount Surrounds 17 Fan Installation 18 Brick Installation 19 Porcelain Panel Installation Guide 20 General Glass Information 21 Gas Line Installati...

Страница 4: ...LED IN MANUFACTURED MOBILE HOMES Please follow the current ANSI NFPA 70 National Electrical Code in the USA and CAN CSA C22 1 Canadian National Electrical Code in Canada An appliance must be grounded...

Страница 5: ...iately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water 12 WARNING Do not operate appliance with t...

Страница 6: ...terminal must be used and if applicable a Product approved air intake must be used Installation shall be in strict compliance with the manufacturer s instructions A copy of the installation instructi...

Страница 7: ...d installation with a top vent is possible as long as the hori zontal portion of the vent system does not exceed 20 feet 6 1 m A Flat on a wall D As a room divider B Across the corner E Flat on wall c...

Страница 8: ...ust be raised a minimum of 2 7 8 above the finished floors to accommodate the wall surround The fireplace may be raised higher but the 60 clearance measured from the bottom of the fireplace to the cei...

Страница 9: ...9 Z33CVCK Framing and Facing Requirements MQZDV3318 WITH Z33CVCK CLEAN VIEW CIRCULATING KIT Z33CVCK with Wall Surround...

Страница 10: ...nd installation with a top vent is possible as long as the hori zontal portion of the vent system does not exceed 20 feet 6 1 m A Flat on a wall D As a room divider B Across the corner E Flat on wall...

Страница 11: ...the fireplace must be raised a minimum of 2 1 2 above the finished floors to accommodate the wall surround The fireplace may be raised higher but the 60 clearance measured from the bottom of the firep...

Страница 12: ...12 Z36CVCK Framing and Facing Requirements MQZDV3622 WITH Z36CVCK CLEAN VIEW CIRCULATING KIT Z36CVCK with Wall Surround...

Страница 13: ...hers skip to Step 4 Using screws provided fasten the non combustible header onto the top of CVCK assembly 4 Hang CVCK onto top of fireplace retainer tabs and rotate into position Fig 2 5 Using 4 suppl...

Страница 14: ...MQZDV3318 3622 Mantels Surrounds Warning Combustible objects must not be placed on a non combustible mantel unless the non combustible mantel meets the minimum height and width requirements for a comb...

Страница 15: ...o or over the front face of the fireplace NO PORTION OF GRILL AREA OR DOOR AREAS CAN BE COVERED except where designer clean view kit is used Combustible material can extend flush to unit up to the top...

Страница 16: ...ance For units with CVCK Clear View Circulating Kit see framing with CVCK to establish floor heights MQZDV3622 Clearance to Combustibles Clearance to Combustibles Back from Standoffs 0 inches 0 mm Sid...

Страница 17: ...G 8 3 4 8 3 4 H 1 1 I 1 3 16 1 3 16 1 Set Surround Lip on CVCK Ledge and ensure that it is securely in place 2 Swing the upper portion of the Surround so that the Surround Ledge is resting on top of t...

Страница 18: ...o 120v Install a duplex outlet to junction box and plug fan into outlet 4 Turn the wall switch on clockwise Turn fireplace on Once the sensor in the unit reaches operating temperature approximately 10...

Страница 19: ...firebox When placing Panel tilt panel towards you and lift panel over the burner assembly Fig 2 5 To place side Liner Panels rotate panel towards you and place bottom edge of panel over the front ledg...

Страница 20: ...e panel tilt it towards you while lifting it over the burner assembly 5 To place the side liner panels rotate it towards you while placing the bottom edge over the front ledge of the firebox Then rota...

Страница 21: ...ed fittings Always pro vide a union so that gas line can be easily disconnected for burner or fan servic ing See gas specification for pressure details and ratings 4 When a vertical section of gas pip...

Страница 22: ...oval Instructions 2 Disconnect gas line connection at burner system through access cover opening 3 Remove extension knobs and wiring from face of gas valve 4 Remove screws from perimeter of burner sys...

Страница 23: ...pilot screw to provide proper sized flame Caution Do Not Wire 120 Volt PowerTo Millivolt Switches Or Thermostats Recommended Maximum Lead Length Double Wire When Using Wall Switch or Thermostat Wire...

Страница 24: ...etting Loosen screw on the side of air mixing tube and rotate to the correct opening using a dirll bit or tape measure Tighten screw 7 After converting parts to the new type of gas reverse all step s...

Страница 25: ...amped on the side of the injector near the top LPG injectors have a groove machined around their circumference near the top while NG injectors do not have a groove 5 Refer to the Appliance Manufacture...

Страница 26: ...rminals at wall switch If burner comes on replace Switch ON defective wall switch If okay jumper wires across wall switch wires at valve If burner comes on wires are faulty or connec tions are bad Gen...

Страница 27: ...glowing rock wool on burner as shown in step 1 being sure to leave the multiple porting areas open For Lp only the multiple porting areas can be completely covered Do not cover the Rear Porting areas...

Страница 28: ...ectly over top of the multiple porting area on the left side Step 5 Fill in the rest of the burner pan and ember plates with lava rock and vermiculite Do not place lava rock or vermiculite on any of t...

Страница 29: ...ove the 2 ember plates once the grate bar is removed The 2 screws removed must be re installed once the grate bar is removed Step 3 Using the left ember plate mounting bracket slide the left ember pla...

Страница 30: ...ure that they are crossing over the single line porting MQRSP5 finished setup and burn Step 8 Place rock 3 and rock 1 into position as shown to complete the setup Lava rock and vermiculite are optiona...

Страница 31: ...fami ly dwellings and serves both dwellings 4 Permitted only if veranda porch deck or balcony is fully open on a minimum of two sides beneath the floor 5 Clearance in accordance with local installati...

Страница 32: ...e Venting Kingsman Flex pipe is shipped in unexpanded length When installing pipe expand the lengths Pipe can be expanded to twice their lengths e g 4ft to 8ft Fully expand pipe and cut off excess Do...

Страница 33: ...ght of the system and the number of bends required 2 Having determined the vertical distance determine the maxi mum horizontal section allowed 3 Vent table has been established for 90 horizontal verti...

Страница 34: ...assing through a ceiling or floor If an attic insulation shield is to be used a fire stop is not required Roof Flashing Ensure that you have the proper roof flashing by checking your roof pitch using...

Страница 35: ...IR INTAKE ADJUSTMENT PLATE NOTE Unit comes preset for short horizontal or vertical venting under a 15 feet run Follow these instructions when venting exceeds 15 foot run 1 Locate the 3 x 1 4 hex screw...

Страница 36: ...Surround Slim Line Antique Brass Z33SLCR Surround Slim Line Chrome Z33SLPB Surround Slim Line Polish Brass Z33SLBL Surround Slim Line Gun Metal Black Designer Doors for 33 Fireplaces Operative Z33DDA...

Страница 37: ...AB Surround Slim Line Antique Brass Z36SLCR Surround Slim Line Chrome Z36SLPB Surround Slim Line Polish Brass Z36SLBL Surround Slim Line Gun Metal Black Designer Doors for 36 Fireplaces Operative Z36D...

Страница 38: ...iece Kit Catalog Number Description ZDVHSK Horizontal Vent Starter Kit 3 FT Length Horizontal Vent Termination Wall Thimble 36 Flex Pipe Mill Pac ZDVHSK5 Horizontal Vent Starter Kit 5 FT Length Horizo...

Страница 39: ...service or maintenance h damage repairs inoperation or inefficiency resulting from faulty installation or application i electricity or fuel costs or any increase in electricity or fuel cost whatsoeve...

Отзывы: