background image

 

30

 

 

WARRANTY 

 

W A R R A N T Y  

PST 250 HEAT PUMP / PST 250 SOLAR HEAT PUMP 

 

By  this  warranty,  Paneles  Solares  Termodinámicos  S.L., 
hereafter  Solar  PST,  with  registered  office  at  the  Polígono 
Industrial  de  Bergondo,  C/  Parroquia  de  Rois  parcela  F1, 
Edificio  Solar  PST,  15165  La  Coruña,  Spain  and  CIF  B-
15982879, guarantees that the product specifically mentioned 
later is free from defects in materials and workmanship from 
the date of its purchase by the buyer from the retailer, or at 
most  upon  its  delivery,  regardless  of  its  final  date  of 
installation  and/or  start-up,  and  for  the  period  below 
mentioned  per item. 
 
This  warranty  is  valid  against  any  manufacturing  defects.  It 
excludes  any  payment  of  damages  to  persons,  or  for  direct 
and  indirect  damages  to  elements  and/or  materials.  This 
warranty  is  valid  only  accompanied  by  the 

original  purchase 

receipt

  given  to  the  buyer,  and  filled  in  due  form,  including 

date of purchase with the following items: 

 

a)

 

Full name of the Buyer 

b)

 

Name, Signature and Seal of the Retailer 

c)

 

Product Model and Serial No. 

d)

 

Date of Purchase 

 
This  warranty  covers  the  replacement  of  the  elements 
damaged during the coverage period. The replacement of any 
element  during  the  framework  of  warranty  does  not  extend 
its  duration,  and  the  replaced  elements  shall  become  the 
property of Solar PST. 
Regarding the Warranty parts return, these must be returned 
in  the  same  conditions  as  they  were  shipped,  original  or 
similar  packaging.  The  compressors'  valves  must  have  their 
original copper caps on. 
The exchange of the parts under warranty will be sent by the 
Solar  PST  distributor  together  with  the  device  serial  number 
and a copy of the purchase invoice. 
 
The periods stated below shall begin on the date of purchase, 
or at  most upon the  delivery of the  goods, regardless of  the 
date of installation or start-up.  

 
PST 250 HEAT PUMP:  2-year warranty 
PST 250 SOLAR HEAT PUMP:  2-year warranty 
 

This warranty specifically excludes: 
 

 

Periodic inspections, maintenance and repair or 
replacement of parts damaged as a result of normal wear 
and tear. 

 

Consumable items, or subject to wear and tear, (switches, 
resistances, thermostats, timers, etcetera). 

 

Travel charges, labor costs and carriage costs for parts. 

 

Thermoaccumulators which work with water containing 
active chlorine, + - 0´2 p.p.m., and Ph + - 6, (Sorensen 
scale at 25º). 

 

Installing  and/or  configuring  the  product  according  to 
requirements  different  from  the  ones  specific  of  the 
product,  (or  the  ones  established  by  Solar  PST  official 
service),  or  not  compliant  with  the  current  technical  or 
security standards. 

 

Manipulation  or  repair  attempts  by  non-  authorized 
technical service providers. 

 

Failures or damage caused to the product due to: Electric 
discharges,  Flooding,  Hail,  Dampness,  Impacts,  Misuse  of 
the Equipment, Galvanic Coupling, Corrosion due to Fixing 
with  Iron  Screws  or  Non-Stainless  Steel  Holders,  Badly 
Fixed Collectors, Fracture of the Collectors Capillary Tube 
due to Vibrations, Acts of God such as Accidents, Natural 
Disasters,  Unpredictable  Weather  Phenomena  or  Any 
Other Cause Beyond SolarPST Control. 

 

The  lost  profits,  lucrum  cessans,  arising  from  the  non-
performance of the system. 

 
The  manipulation  or  repair  attempts  by  technical  service 
providers  not  authorized  by  Solar  PST  may  extinguish  the 
rights granted by this Warranty. 

 

THE DISTRIBUTOR 

 

THE BUYER 

 

 

 

 
 

Calle Parroquia de Rois. Nave F1. Polígono de Bergondo. Edificio SolarPST. 15165 BERGONDO – La Coruña. Spain 

Tel. 00 34 981783669  Fax 00 34 981 795325  [email protected]  www.solarpst.com

 

Содержание PST-250 Aero Termo

Страница 1: ...Domestic Hot Water Heat Pump Operation and Installation Manual ENGLISH 02 07 2012...

Страница 2: ...up the unit Retain this manual for future reference Before operating the unit make sure the installation has been carried out correctly by a professional dealer If you feel unsure about operation con...

Страница 3: ...space 13 Choose the suitable unit 14 Transportation 14 Installation positions 15 Water loop connection 17 Wire connection 17 Trial running 17 OPERATING THE UNIT 18 Features and functions 18 User inter...

Страница 4: ...ot water and fresh air ventilation Units can be placed in the garage gym basement etc When it produces hot water it cools the room and supplies fresh air Compatible with different energy sources Units...

Страница 5: ...s required When installing the unit in a small room please take measures like sufficient ventilation to prevent the asphyxia caused by the leakage of refrigerant Use the specified electrical wires and...

Страница 6: ...Do not install the unit in a place where there is a chance of flammable gas leaks If there is a gas leak and gas accumulates in the area surrounding the unit it could cause an explosion Perform the d...

Страница 7: ...SIDE PRODUCT BOX Before starting the installation please make sure that all parts are found inside the box The Unit Box ITEM IMAGE QUANTITY Domestic hot water heat pump 1 Operation and Installation Ma...

Страница 8: ...8 OVERVIEW OF THE UNIT Parts and descriptions...

Страница 9: ...he Magnesium stick is an anti corrosion element It is assembled in the water tank to avoid the creation of fur around the inside tank and to protect the tank and other components It can help to extend...

Страница 10: ...10 Water tank dimensions...

Страница 11: ...the power of the unit OFF and pull out the plug Drain all the water out of the tank Remove the old magnesium stick from the tank Replace the new magnesium stick Recharge the water Schematic overview...

Страница 12: ...d cause damage to the unit or even hurt people The set point of this safety valve is 0 7 MPa The discharge pipe connected to the one way safety valve is to be installed in a continuously downward dire...

Страница 13: ...13 Required service space Below you will find the minimum space required to be able to complete service and maintenance tasks on the units EN...

Страница 14: ...e an inclination angle up to 30 degrees is permitted both during transport and storage Ambient temperatures of 20 to 70 degrees Celsius are permitted Transport using a forklift When transported by a f...

Страница 15: ...umber of waste heat so that the unit has the higher energy efficiency even with very low outside temperatures during the winter 2 Hot water and dehumidification Units can be placed in the laundry room...

Страница 16: ...t cools the room and supplies the fresh air 4 Solar panel or external heat pump could be the second heat source optional under request Units can work with solar panel external heat pump boiler or othe...

Страница 17: ...ping system must be avoided Wire connection The specification of the power supply wire is 2 5 mm Fuse specification is T 3 15A 250V There must be a switch when connecting the unit to the power system...

Страница 18: ...he off status or standby status of the unit 2 When the temp of the water tank top T2 TS3 Parameter 04 the electric heating stops When the temp of the water tank top T2 TS3 2 C the electric heating sta...

Страница 19: ...ters into the standby modus 2 button Press this button when the unit is standby the unit can be turned ON and runs on the setting mode The running mode temperatures timer situation and clock time are...

Страница 20: ...firm the setting If no action to the buttons for 5 seconds the controller will exit and save the setting automatically NOTE a You can check and adjust the set parameters during standby modus you canno...

Страница 21: ...dden power cut b During the clock setting the TIMER button is invalid c Press the CLOCK button to cancel the timer setting during the timer programming 6 ELEC HEATING button Press this button to turn...

Страница 22: ...t water temperature reaches the set point The hot water is available for use Heat pump is standby 5 Electrical heating The icon indicates that the electrical heating function is enabled The electrical...

Страница 23: ...d 1 12 min 8 min Adjustable 10 Electronic expansion valve adjustment 0 1 1 Adjustable 0 manual 1 auto 11 Target over heat degree 20 20 C 5 C Adjustable 12 Steps of manually adjusting the electronic ex...

Страница 24: ...mbient temp sensor failure PP5 5 flashes 1 dark High pressure protection EE1 6 flashes 1 dark Low pressure protection EE2 7 flashes 1 dark Over heat protection EE3 8 flashes 1 dark Defrost Defrosting...

Страница 25: ...nd split the pipe Keep the unit clean by means of soft damp cloth no maintenance is required by the operator TROUBLESHOOTING This section provides useful information for diagnosing and correcting cert...

Страница 26: ......

Страница 27: ...27 WIRING DIAGRAM Please refer to the wiring diagram on the electric box EN...

Страница 28: ...pressure MPa 0 7Mpa Inside body material of tank Thickness mm INOX SUS 304 1 5 mm Insulation material Polyurethane Thickness of the tank insulation mm 45 Coating thickness of the tank cover mm 0 6 Aux...

Страница 29: ...89 6 33 6 9814 91 4 34 6 6836 93 2 35 6 4002 95 0 36 6 1306 96 8 37 5 8736 98 6 38 5 6296 100 4 39 5 3969 102 2 40 5 1752 104 0 41 4 9639 105 8 42 4 7625 107 6 43 4 5705 109 4 44 4 3874 111 2 45 4 212...

Страница 30: ...f the purchase invoice The periods stated below shall begin on the date of purchase or at most upon the delivery of the goods regardless of the date of installation or start up PST 250 HEAT PUMP 2 yea...

Страница 31: ...31 NOTES EN...

Страница 32: ...Calle Parroquia de Rois nave F1 Pol gono Industrial de Bergondo 15165 Bergondo La Coru a Espa a info solarpst com www solarpst com T 00 34 981 783 669...

Отзывы: