background image

SOLAR Power Inverter USER’S MANUAL

How Power Inverters Work

Power inverters utilize a two-step method to convert 12 Volt direct current (DC) power into 115 Volt AC power. In
the first step, the power inverter uses a DC to DC converter to increase the DC voltage from the original 12 Volts
DC to 145 Volts DC. In the second step, the power inverter converts high voltage DC power into 115 Volt AC power
using advanced micro-circuitry which we refer to as Sonic Compression technology.

It is this Sonic Compression technology that enables SOLAR power inverters to accommodate strenuous “peak
power” and “continuous power” demands, while at the same time, providing the assurance of automatic overload
protection.  

The modified sine wave produced using our Sonic Compression technology has a root mean square (RMS) voltage
of 115 Volts. Most AC voltmeters are calibrated to measure the RMS voltage of a pure sine wave. For this reason,
most voltmeters will not measure the output voltage of your power inverter correctly, typically showing an output
about 20-30 Volts below the actual output. To accurately measure the output voltage of your SOLAR power inverter,
use only a voltmeter identified as a “True RMS” reading voltmeter.

Things to remember when operating your 

SOLAR

power inverter:

Loose connections can result in a severe decrease in voltage and may cause damage to the wires and insulation in
the power inverter. Always check that all connections are correct and secure prior to powering the inverter and any
device connected to it.

Failure to make a proper connection between the power inverter and the 12 Volt power source can result in a
reverse polarity condition. A reverse polarity condition will blow the internal fuse(s) of the inverter and may cause
permanent damage to the inverter. Damage caused by a reverse polarity condition is not covered in the warranty.  

When making the connection between the Positive terminals of the power inverter and the 12 Volt power source, it
is possible that you may create a spark. For this reason, it is critical that both the power inverter and the 12 Volt
power source not be positioned in the vicinity of flammable fumes or gases.

When attempting to power any device using your inverter, monitor the temperature of the device for approximately
10 minutes. If the device being powered becomes abnormally warm, disconnect it from the power inverter
immediately.

When using an automobile or marine battery to power the inverter, start the vehicle’s engine every 30 to 60 minutes
and let it run for approximately 10 minutes to recharge the vehicle’s battery. We recommend that the device being
powered by the inverter, as well as the inverter itself, be turned 

OFF

before starting the vehicle’s engine.  

When your power inverter is not in use and turned 

OFF

, it draws a very low amperage from the 12 Volt power source

when connected. As a result, we recommend that you disconnect the power inverter from the 12 Volt power source
when not in use.

Use of an extension cord between the SOLAR power inverter and the device being powered will not significantly
decrease the power generated by the power inverter. For best results, do not use an extension cord longer 
than 50 ft.

SOLAR

Power Inverter Safety Features

Your SOLAR power inverter is equipped with automatic shut off protection which will be activated if any of several
unsafe operating conditions exist. In the event that any of the following conditions occur, the Fault Indicator light
will turn on and the power inverter will shut down:

1. The power input from the 12 Volt power source drops to 10.0 Volts. (When the power from the 12 Volt power

source drops to 10.5 Volts, an extended audible alarm will sound, warning you that your power source is low.)

2. The power input from the 12 Volt power source exceeds 15.0 Volts.

3. The “continuous power” demand from powered devices exceed the power rating of your inverter.

4. The “peak power” demand from the powered device exceeds the peak power rating of your power inverter.

5. The circuit temperature within the power inverter exceeds 149˚F (65ºC).

In the event the automatic shut down protection occurs or the inverter sounds a continuous audible alarm, turn 

OFF

the power inverter immediately. Do not restart the power inverter until the source of the problem has been identified
and corrected.

5

Содержание PI10000X

Страница 1: ...eyes Read entire instruction manual before use WARNING Warning This product contains chemicals including lead known to the State of California to cause cancer birth defects and other reproductive har...

Страница 2: ...quires warranty service please call Technical Service at 913 310 1050 Save your purchase receipt it is required for warranty service Table of Contents Safety Summary Warnings 3 Personal Precautions 4...

Страница 3: ...surfaces Do not attempt to plug in this unit or operate its controls with wet hands or while standing in water This unit is intended for indoor use only Never attempt to plug in or operate equipment w...

Страница 4: ...f the power inverter Avoid placing the power inverter near sources of heat such as heat vents and radiators or in direct sunlight Loose connections can result in a severe decrease in voltage may cause...

Страница 5: ...the power inverter and the 12 Volt power source not be positioned in the vicinity of flammable fumes or gases When attempting to power any device using your inverter monitor the temperature of the dev...

Страница 6: ...ng the Right Battery Type One of the most important determinants of the success of your installation is your choice of DC power source What types of batteries should be used How large should they be H...

Страница 7: ...t Then multiply the total watt hour requirement for all items times the number of days between charging your battery ies Note This step is unnecessary if you plan to recharge your battery ies nightly...

Страница 8: ...d the best way to deliver the charge The key to a successful charging system is that your battery ies are fully charged and ready for service when you need them next Testing Batteries to Ensure Readin...

Страница 9: ...The fuse or circuit breaker should always be installed on the positive lead Choosing an Installation Location Warning Working around lead acid batteries may be dangerous Lead acid batteries release ex...

Страница 10: ...und cable requirements and connecting to vehicle grounding points For certain applications you are required to properly ground the inverter chassis Your power inverter has a ground screw for grounding...

Страница 11: ...n the AC cable of any device through a wall or other barrier or near any sharp or rough edges always be sure to protect the AC cable from chaffing When disconnecting any device powered by the power in...

Страница 12: ...m damage due to excessively deep cycling Connecting and Powering AC Equipment Always ensure that both the power inverter and the equipment to be powered are OFF when connecting the equipment to the po...

Страница 13: ...sine wave power source To determine the power needs of a particular device use the following formulas Amps Indicated x 110 AC Voltage Watts This Wattage amount is roughly equivalent to the continuous...

Страница 14: ...keep your power inverter working and looking good for years Check your battery and DC input connections regularly to ensure that they are tight and free of corrosion Wipe off any battery fluid at the...

Страница 15: ...dropped below 10 Volts check 12 Volt power source voltage and recharge as needed Answer The device being powered is placing a power demand on the inverter that is beyond its operating capacity use a...

Страница 16: ...S Short Circuit Protection YES No Load Current Draw 0 8 A DC Fuse 18 x 20A AC Output Voltage 115VAC RMS 10 AC Output Frequency 60 Hz 3 Hz Output Waveform Modified sine wave Maximum continuous AC Power...

Страница 17: ...NY SHALL NEVER EXCEED THE PURCHASE PRICE OF THIS MACHINE REGARDLESS OF WHETHER LIABILITY IS PREDICATED UPON BREACH OF WARRANTY EXPRESS OR IMPLIED NEGLIGENCE STRICT TORT OR ANY OTHER THEORY Some states...

Страница 18: ...18...

Страница 19: ...vicio t cnico al 913 310 1050 Guarde la factura de compra ya que se precisa para la reparaci n con cobertura de garant a ndice Resumen de seguridad y advertencias 20 Precauciones personales 21 Instruc...

Страница 20: ...ducto contiene sustancias qu micas incluido plomo que el Estado de California sabe que producen c ncer defectos de nacimiento y otros perjuicios para la reproducci n L vese las manos despu s de manipu...

Страница 21: ...mentaci n de 12 voltios de CD NUNCA intente conectar el inversor de corriente SOLAR a otro tipo de fuente de alimentaci n incluida toda fuente de CA El inversor de corriente est dise ado para conectar...

Страница 22: ...tura de garant a Al conectar los terminales positivos del inversor de corriente y la fuente de 12 voltios es posible que se produzca una chispa Por eso es vital que el inversor de corriente y la fuent...

Страница 23: ...rtante que eval e su aplicaci n espec fica y dise e su sistema de inversi n de corriente de modo que satisfaga sus necesidades Tambi n es importante que se asegure de cumplir todas las normas municipa...

Страница 24: ...S lo al suministrar la potencia necesaria de 12 Voltios se puede lograr la potencia m xima de salida especificada para el inversor de corriente Existen varias maneras distintas de especificar la canti...

Страница 25: ...de recarga apropiado para su caso particular Si el sistema de recarga no es el adecuado las bater as de alimentaci n podr an descargarse en exceso lo que reduce dr sticamente su vida til Tambi n puede...

Страница 26: ...i n de CC deben ser tan cortos como sea posible y de la longitud adecuada que permita colocar el inversor en un recinto distinto al de las bater as consulte Selecci n del lugar de la instalaci n Recom...

Страница 27: ...peraci n y de almacenamiento del inversor de corriente los inversores no se deben instalar en los compartimientos de los motores Los inversores de corriente no se deben colocar en el mismo recinto de...

Страница 28: ...tensidad de la corriente de cortocircuito de su fuente de potencia de 12 voltios puede ser extremadamente alta es importante la instalaci n de un fusible o de un ruptor de circuito entre las bater as...

Страница 29: ...del cable NO opere con dispositivos o aparatos cuyos cables de alimentaci n est n da ados Conexi n de Salida de la Caja de Empalmes El inversor de alimentaci n est equipado con una opci n de salida d...

Страница 30: ...var el interruptor de encendido del inversor en el panel de salida a la posici n de apagado para apagar el inversor Al alimentar m s de un equipo simult neamente con el inversor de corriente encienda...

Страница 31: ...ficado y corregido el origen del problema Alimentaci n de cargas de alta potencia pico Ciertos tipos de equipos que utilizan motores de inducci n consumen potencias muy altas por breves per odos debid...

Страница 32: ...aci n para determinar los fusibles correctos para su producto Modelo Cant de fusibles Capacidad del fusible Tipo de fusible PI30000X 18 20 Amp Mini cuchilla Antes de abrir el gabinete del inversor par...

Страница 33: ...alimentaci n de 12 voltios Verifique las conexiones entre la fuente de alimentaci n de 12 voltios y el inversor de corriente Problema Mala recepci n de dispositivos de audio o televisi n Respuesta Co...

Страница 34: ...TODOS LOS RIESGOS DE PERDIDA POR CUALQUIER MOTIVO CORREN POR CUENTA DEL COMPRADOR CLORE AUTOMOTIVE NO SE HACE RESPONSABLE POR LOS DA OS INCIDENTALES O FORTUITOS BAJO NINGUNA CIRCUNSTANCIA LA RESPONSA...

Страница 35: ...35...

Страница 36: ...10 1050 Gardez pr cieusement votre re u Vous devrez le pr senter pour tout service de garantie Table des mat res R capitulatif et avertissements sur la s curit 37 Pr cautions personnelles 38 Instructi...

Страница 37: ...its chimiques notamment du plomb identifi s par l tat de la Californie comme tant canc rig nes et facteurs d anomalies cong nitales et d autres troubles de la reproduction Lavez vous les mains apr s t...

Страница 38: ...alimentation fournis une source d alimentation 12 volts N essayez jamais de modifier les cordons fournis ni d avoir recours d autres moyens pour relier la source d alimentation 12 volts N utilisez pas...

Страница 39: ...t longs pour vous permettre de l utiliser l endroit souhait vous pouvez raccorder l onduleur lectrique la source d alimentation l aide d un c ble AWG n 4 Les m mes proc dures et pr cautions que celles...

Страница 40: ...ction reportez vous au sch ma d installation de l onduleur lectrique la page 11 pour un exemple d installation type Conformit des installations au Code Votre onduleur lectrique est une pi ce d quipeme...

Страница 41: ...atteries de d marrage la puissance nominale est exprim e en amp res de d marrage ou en amp res de d marrage froid Bien que ces mesures constituent une excellente fa on de d terminer la viabilit d une...

Страница 42: ...que le syst me de recharge choisi soit compatible avec l onduleur et la ou les batteries utilis es Dans tout le pr sent manuel nous d signons l installation compl te par le terme syst me d onduleur le...

Страница 43: ...les batteries d alimentation et l onduleur lectrique Les c bles exc dant les longueurs recommand es peuvent entra ner un rendement m diocre de l onduleur et faire en sorte qu il soit impossible d att...

Страница 44: ...vu sur tous les c t et le dessus de l onduleur lectrique pour permettre la circulation d air et il faut particuli rement prendre garde de ne pas obstruer les prises d air la base et aux extr mit s de...

Страница 45: ...sible disjoncteur sur les bornes c c de l onduleur voir Exigences relatives aux fusibles disjoncteurs en vous assurant que le sectionneur ou le disjoncteur et mis hors tension avant l installation Con...

Страница 46: ...t la puissance de sortie pr lev e des appareils et de l quipement connect s Lorsqu il est sous tension sans tre utilis l onduleur lectrique impose seulement une petite charge sur les batteries d alime...

Страница 47: ...d affichage est tr s utile pour d terminer si l onduleur lectrique pourra alimenter une pi ce d quipement additionnelle sans d passer sa puissance nominale valuation de la compatibilit de l onduleur l...

Страница 48: ...conditions d utilisation 1 Assurez vous que l antenne de t l vision l antenne audio de l appareil met un signal clair dans des conditions normales d utilisation appareil branch une prise 110 volts CA...

Страница 49: ...que l onduleur lectrique est mis sous tension ON et que l appareil alimenter est mis sous tension ON Solution Assurez vous que la polarit de la connexion c c est appropri e Si la connexion a t invers...

Страница 50: ...asse tension 10 5V OUI Arr t sur basse tension 10 V OUI Arr t sur surtension 15 V OUI Protection contre la surchauffe 149 F OUI Ventilateur de refroidissement OUI Protection contre les surcharges OUI...

Страница 51: ...ACHETEUR EN AUCUN CAS CLORE AUTOMOTIVE NE POURRA TRE TENUE RESPONSABLE DE DOMMAGES ACCESSOIRES ET CONS QUENTS LA RESPONSABILIT DE CLORE AUTOMOTIVE NE DEVRA JAMAIS EXC DER LE PRIX D ACHAT DE CETTE MAC...

Страница 52: ...User s Manual POWER INVERTERS 2009 Clore Automotive 842 438 000...