Solar FMB1224 Скачать руководство пользователя страница 3

SAFETY INSTRUCTIONS

1. Use of an attachment not recommended or sold by manufacturer may result in a risk of fire, electric shock, 

or injury to persons.

2. To reduce risk of damage to electric plug and cord, pull by plug rather than cord when disconnecting unit.

3. Make sure cord is located so that it will not be stepped on, tripped over, or otherwise subjected to damage 

or stress.

4. An extension cord should not be used unless absolutely necessary. Use of an improper extension cord could 

result in a risk of fire and electric shock. If an extension cord must be used, make sure pins on plug of 
extension cord are the same number, size, and shape as those of plug on unit; extension cord is properly 
wired and in good condition; wire size is large enough for the length of cord as specified in the following 
chart:

Length in feet:

25

50

100

150

Cord AWG size:

16

12

10

8

5. Do not operate unit with damaged cord or plug - replace them immediately.

6. Do not disassemble unit – take it to/or call a qualified technician when service or repair is required.  

Incorrect reassembly may result in a risk of electric shock or fire.

7. To reduce risk of electric shock, unplug unit from outlet before attempting any maintenance or cleaning.

PERSONAL SAFETY PRECAUTIONS

1. Someone should be within range of your voice or close enough to come to your aid when you work near 

a lead-acid battery. Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing 
or eyes.

2. If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters eye, 

immediately flood eye with running cold water for at least 10 minutes and get medical attention immediately.

3.

NEVER

smoke or allow a spark or flame in vicinity of battery or engine.

4. Be extra cautious to reduce risk of dropping a metal tool onto battery. It might spark or short-circuit battery 

or other electrical part that may cause explosion.

5. Remove personal metal items such as rings, bracelets, necklaces, and watches when working with a 

lead-acid battery. A lead acid battery can produce a short circuit current high enough to weld a ring or 
the like to metal, causing a severe burn.

6. When using unit as charger, charge LEAD-ACID batteries only. It is not intended to supply low-voltage 

power for applications other than battery charging. Do not use with batteries that are commonly used 
with home appliances. These batteries may burst and cause injury to persons and damage property.

7.

NEVER

JUMP START OR CHARGE a frozen battery. Any battery that is suspected of being frozen must 

be thawed before jump starting or charging.

GROUNDING AND AC POWER CONNECTION INSTRUCTIONS

Unit should be grounded to reduce risk of electric shock. Unit is equipped with an ac electric cord having an
equipment grounding conductor and a grounding plug. The plug must be plugged into an outlet that is properly
installed and grounded in accordance with all local codes and ordinances.

Never alter the AC cord or plug provided – if it will not fit outlet, have proper outlet installed by a qualified 
electrician. This unit is for use on a 120 Volt, 60 Hz cycle circuit. A temporary adapter may be used to connect 
this plug to a two-pole receptacle if a properly grounded outlet is not available. The temporary adapter should 
be used only until a properly grounded outlet can be installed by a qualified electrician. Before using adapter, 
be certain that center screw of outlet plate is grounded. The green rigid ear or lug extending from adapter must 
be connected to a properly grounded outlet – make certain it is grounded. If necessary, replace original outlet 
cover plate screw with a longer screw that will secure adapter ear or lug to outlet cover plate and make ground 
connection to grounded outlet.

DANGER

Содержание FMB1224

Страница 1: ...NING WARNING 12 24 VOLT MODELS Never hook up a 12 Volt DC power source to a 24 Volt DC vehicle This will grossly overcharge the 12 Volt power source and generate flammable gasses that may explode and cause property damage and or bodily harm Made in U S A Owner s Manual Model Nos HT1224 FMB1224 Commercial Jump Starter Chargers ...

Страница 2: ...Carefully read and follow these instructions for safe use Always follow the specific instructions in this manual and on the SOLAR Jump Starter Charger each time you jump start using the SOLAR Jump Starter Charger All lead acid batteries car truck and boat produce hydrogen gas which may violently explode in the presence of fire or sparks Do not smoke use matches or a cigarette lighter while near ba...

Страница 3: ... risk of dropping a metal tool onto battery It might spark or short circuit battery or other electrical part that may cause explosion 5 Remove personal metal items such as rings bracelets necklaces and watches when working with a lead acid battery A lead acid battery can produce a short circuit current high enough to weld a ring or the like to metal causing a severe burn 6 When using unit as charg...

Страница 4: ...d 5 Unit is ready for use VEHICLE HARNESS FMB1224 MODEL ONLY Two 25 ft 4 gauge cables are provided with FMB1224 for optional charging of unit from vehicle in which the box unit is mounted CONNECTING VEHICLE HARNESS 1 Cables must run from box unit into engine compartment area 2 Do not allow cable to touch any moving parts of engine 3 Positive cable red band connects to alternator 12 Volt output 4 N...

Страница 5: ...ecting unit ALWAYS disconnect the negative clamp from vehicle chassis first Remove positive clamp from battery terminal second CHARGING WARNING UNIT CANNOT CHARGE VEHICLE WITH 24 VOLT SYSTEM UNIT CAN ONLY CHARGE IN 12 VOLT SETTING DO NOT JUMP START WITH AC POWER CORD CONNECTED TO 110 AC POWER SOURCE NEVER JUMP START A FROZEN BATTERY A SPARK NEAR BATTERY MAY CAUSE BATTERY EXPLOSION TO REDUCE RISK O...

Страница 6: ...connect negative Black cable lead from charger chassis 7 Disconnect negative Blue volt gauge lead from charger chassis 8 Disconnect positive Red amp gauge lead from charger circuit breaker 9 Remove rear battery by lifting battery up turning it and sliding it out rear opening of unit 10 Remove front battery by lifting battery up turning it and sliding it out rear opening of unit INSTALLING NEW BATT...

Страница 7: ...HT1224 12 24 HEAVY TRUCK Figure 1 ...

Страница 8: ...ve cable from 12 Volt connector Black 12 gauge wire from Volt gauge b To 2 Battery negative terminal connect One end of 6 negative crossover Black 12 gauge wire from 2 Charger ground tab c To 3 Battery negative terminal connect Other end of 6 negative crossover Negative cable from common connector with handle d To 3 Battery positive terminal connect Positive cable from 12 Volt connector One end of...

Страница 9: ...FMB1224 12 24 FIX MOUNT Figure 2 ...

Страница 10: ...ug See figure of unit to check wiring connections Short across studs on gauge to see if charger comes on replace gauge Replace charger Set to 12 Volt position Possible Cause Quick connects not locked together Poor grip connections Low defective battery Loose jumper cable connection to battery Poor grip connection Faulty 110 AC outlet Bad plug on unit Loose defective connections Defective amp gauge...

Страница 11: ...ect to your SOLAR Commercial Jump Starter Charger is limited to the period of the express warranty set forth above This warranty excludes and does not cover defects malfunctions or failures of your SOLAR Commercial Jump Starter Charger which were caused by repairs made by an unauthorized person mishandling modifications normal wear unreasonable use or signs of battery adic corrosion from improper ...

Страница 12: ...HT1224 FMB1224 Commercial Jump Starter Chargers READ MANUAL CAREFULLY BEFORE OPERATING UNIT WARNING This product contains chemicals including lead known to the State of California to cause cancer birth defects and other reproductive harm Wash hands after handling 2006 Clore Automotive 841 022 000 ...

Страница 13: ...ct online at www cloreregistration com WARRANTY AND TECHNICAL SUPPORT REGISTRATION CARD Model Number ____________________________________________________ Date of purchase ___ ___ ___ Purchased from _______________________ Company Name ___________________________________________________ Shipping Address __________________________________________________ City ______________________ State _________ P...

Страница 14: ...N CLORE AUTOMOTIVE 8735 ROSEHILL RD STE 220 LENEXA KS 66215 9901 NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES BUSINESS REPLY MAIL FIRST CLASS MAIL PERMIT NO 5445 SHAWNEE MISSION KS POSTAGE WILL BE PAID BY ADDRESSEE ...

Отзывы: