Then 14 three times, pauses then repeats, then the total lamp hours stored in that T-MAX® 005 is 5314.
4) Press the Up and Down buttons to change the parameter to the desired value.
If you want to clear the value for that parameter, press the Up and Down buttons at the same
time until the display shows “.0”.
5) Press the Start/Stop Button.
The display will show the parameter number you just changed and a solid period in the lower
center of the display. You may now change another parameter by pressing the Up or Down buttons
until the parameter that you want to change is displayed. Repeat Steps 2-4 for each parameter you
want to change.
6) To exit the Parameter mode and make the T-Max® 005 available for the next session, press and hold both
the up and down buttons until the display shows a 0 with no periods displayed.
Table 1 - Parameter numbers for observing and changing parameters.
*If Manual Lockout is enabled, the T-Max® 005 cannot operate as a stand alone timer.
2.1 Setting the Address
Note: If you are using the T-Max® 005 as an independent timer, you don’t need to set the address.
1) Press and hold the Start/Stop and Up buttons simultaneously on the T-Max® 005 until a .1” appears
on the display. Release the buttons.
2) Press and release the Start/Stop button. A number will appear on the display and be flashing.
A period will be illuminated in the center of the display.
Param# Description
Max # Default Notes
1
Address
255
254
Address of T-Max® 005
2
Beep Mode
1
0
Used for High Power beds. 0=Alarm only, 1=Alarm and Flip
3
Delay Time
10
0
Delay in minutes stored in the T-Max® 005.
4
Current Sense
1
0
For the T-Max® Sentry™ Option. 0=Disabled. 1=Enabled.
5
Session Counts
65535 0
Total session counts for T-Max® 005.
6
Lamp Hours
65535 0
Bulb hours for each bed.
7
Bed Hours
65535 1
Number of hours a bed is on.
8
Manual Session
Counts
65535 0
Counts the number of sessions the T-Max® 005 has run while in
Stand Alone Mode
9
Clean Room
1
1
0 = Clean Room Disabled. I = Enabled
10*
Manual Lockout
1
0
0 = Stand Alone Enabled. 1 = Disabled
13
Cool Down Mode
10
0
0 = Disabled, 1- l0=Enabled. Time delay in minutes allowing bed to
cool.
15
Fixed Session Counts
65535 0
Counts number of sessions ran through theT-Max®005.
This value cannot be changed at all. Used as point of reference.
19
Third Party
Interface (TPI) Mode** 1
0
Used for input for timing systems other than the T-Max® Series.
Contact closure input. 0=Disabled; l=Enabled.
20
External Speaker
1
0
0 = Speaker on theT-Max®005, 1 = External Speaker will be used.
21
Pause Mode
1
0
0 = When session is paused, time will continue to count down. 1 =
When session is paused, session time will stop counting down.
22
Auto Bed Shut Off
1
0
For T-Max® Intercom Systems Only. 0 = When timer is called bed will
stay on, 1 = When timer is called, bed will stuff off automatically.
Timer-2