1
SAB12-0429_08_Installation and Maintenance Manual SFxxx-S
3
Electrical Data at Nominal Operating Cell Temperature Conditions (NOCT 47
°
C)
SF135-S
SF140-S
S145-S
SF150-S
SF155-S
SF160-S
SF165-S
SF170-S
Maximum Power
Pmax
100W
104W
108W
111W
115W
119W
123W
126W
Open Circuit Voltage
Voc
96.5V
97.4V
97.4V
98.3V
99.2
100V
100V
102V
Short Circuit Current
Isc
1.68A
1.68A
1.76A
1.76A
1.76A
1.76A
1.76A
1.76A
Maximum Power
Voltage
Vmpp
75.0V
75.5V
76.0V
76.4V
77.4V
78.8V
80.2V
82.1V
Maximum Power
Current
Impp
1.34A
1.38A
1.43A
1.47A
1.49A
1.51A
1.53A
1.55A
3.2 Module Performance at Low Irradiance
Efficiency reduction of maximum output from an irradiance of 1,000 W/m
2
to 200W/m
2
at 25°C is typically 2.0%.
The standard deviation for the reduction in efficiency is 1.9%.
3.3 Thermal Characteristics
NOCT
47°C
Temperature Coefficient of Isc
1
+ 0.01 % / K
Temperature Coefficient of Voc
2
- 0.30 % / K
Temperature Coefficient of Pmax
3
-0.3
1
% / K
3.4 Characteristics for System Design
Maximum System Voltage
Vsys
1000V IEC / 1000V UL
Limiting Reverse Current
Ir
7A
Maximum Series Fuse Rating
Isf
4A
•
The sum of Voc for modules in series must not exceed the maximum system voltage of the module under any
condition, this includes at low temperature.
•
Reverse current applied to the modules should not exceed 7A under any circumstances.
UL:
Modules installed in a parallel will be provided with the listed maximum series fuse, as specified.
3.5 Mechanical Data
Dimensions (L x W x H)
1257 x 977 x 35 mm (49.5 x 38.5 x 1.4 in)
Weight
20.0 kg (44.1 lbs) / 16.3 kg/m
2
(3.3 lbs/ft
2
)
Module Operating Temperature
-40°C to 85°C
Application Class on IEC61730
Class A
Fire Safety Class on IEC61730*
1
Class C
Cable
2.5mm
2
/ 14AWG (Halogen Free)
Snow Load (to the front of the module) *
2
2400 Pa (IEC61646) / 1600Pa design load (UL1703)
Wind Load (to the back of the module)
2400 Pa (IEC61646) /1600Pa design load (UL1703)
*1 UL: The fire rating of this module is valid only when mounted in the manner specified in the mechanical mounting instructions.
*2 UL: The load applied to a module under UL testing conditions is 1.5 times greater than the module’s design load. Accordingly, 2400
Pa (50 lbs /ft
2
) is loaded to test the 1600 Pa (33.4 lbs /ft
2
) UL design load .
Содержание SF135-S
Страница 10: ...6 9...
Страница 11: ......
Страница 14: ...8 9 B B BB 1 BB BB BB ABBB B CCC 1...
Страница 18: ......
Страница 49: ...SAB12 0669_02_Installation and Maintenance Manual SFxxx S 13...
Страница 63: ...1 SAB12 0429_08_Installation and Maintenance Manual SFxxx S 13 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1...