Solar module mounting instructions

Mono S3 

 Mono S2 

 M series 

 P series

Danger to life due to high voltage!

High contact voltages can still occur in the inverter 

even when it is disconnected. For this reason, the 

following applies:

 

 Exercise extreme caution when working on the 

inverter and the cables.

 

 In  order  for  the  high-voltage  components  to 

discharge,  it  is  essential  to  observe  the  time 

intervals specified by the inverter manufactu

-

rer after switching off the inverter and before 

starting any further work. Always observe the 

mounting instructions of the inverter manufac

-

turer.

Danger to life from electric arc!

When exposed to light, solar modules produce di

-

rect current. If a closed circuit is opened, e.g. when 

the DC line is disconnected from the inverter under 

load, a fatal electric arc can occur.

 

 Under  no  circumstances  disconnect  the  so

-

lar generator from the inverter as long as it is 

connected to the mains.

 

Ensure flawless cable connections.

 

Connect  cables  seamlessly  and  keep  them 

free from dirt.

Electrical installation

The  solar  modules  are  designed  for  use  in  PV 

systems  of  application  class A  and  can  therefo

-

re be operated in systems with dangerous direct 

voltages (greater than 120 V DC according to EN 

61730) and power ratings.

PV modules of this application class may be used 

in systems with unlimited accessibility.

SF Solar Factory GmbH & Co. KG modules of the 

Mono S2, M and P series, which are qualified wi

-

thin this application class according to EN 61730, 

meet the requirements of protection class II when 

installed in accordance with regulations.

 

Transport, intermediate storage and safe
unpacking

The modules are sensitive technical components 

that require great care when handled. Be especial

-

ly careful, therefore, when transporting and tempo

-

rarily storing the modules and leave them in their 

packaging until they are used. Always lift and carry 

the modules with both hands and do not use the 

junction box as a hand grip.

Do not drop the modules or place them roughly on 

hard ground or on the module corners. Do not pla

-

ce objects on the modules. Do not stack modules 

on top of each other without protection.

Avoid  bending  the  modules.  Do  not  step  on  the 

modules. Do not work with sharp objects and keep 

all electrical contacts clean and dry.

It is advisable to note the serial numbers for sys

-

tem  documentation.  If  intermediate  storage  of 

the modules is necessary, a dry, ventilated room 

should be provided.

Clean,  non-slip  gloves  must  be  worn  during  all 

transport  and  installation  work  to  prevent  injury 

from cuts on module edges. In addition, avoid so

-

iling the solar glass with fingerprints, as they can 

damage the special coating of the glass.

It  is  essential  to  observe  the  warnings  on  the 

packaging  and  the  enclosed  unpacking  instruc

-

tions.

Содержание M Series

Страница 1: ...Solar modules Solar module mounting instructions Mono S3 Mono S2 M series P series ...

Страница 2: ...ules are properly earthed 6 Special instructions for handling AR glass modules 7 Ensuring comprehensive fire protection 7 Ensuring a suitable environment 7 Suitable installation situation 7 Correct mounting location 8 Assuring yield through optimum alignment and inclination 8 Installing the module free from shade 8 Ensuring sufficient rear ventilation 8 Secure mounting 8 Instructions for installat...

Страница 3: ...ull cells P series 72 full cells 60 full cells 120 half cells 72 full cells 120 half cells 120 half cells 60 full cells 60 full cells M series 72 full cells 144 half cells 60 full cells 120 half cells 72 full cells 120 half cells 120 half cells 60 full cells Mono S2 144 half cells 120 half cells 120 half cells Mono S3 ...

Страница 4: ...modules is tested at an am bient temperature of 40 to 85 C This range should be observed The modules must not be exposed to excepti onal chemical loads e g emissions from ma nufacturing companies When connecting solar modules to power sto rage units the respective safety instructions of the manufacturer must be observed Attention Danger to life Danger to life from electric shock Solar modules gene...

Страница 5: ...ass may be used in systems with unlimited accessibility SF Solar Factory GmbH Co KG modules of the Mono S2 M and P series which are qualified wi thin this application class according to EN 61730 meet the requirements of protection class II when installed in accordance with regulations Transport intermediate storage and safe unpacking The modules are sensitive technical components that require grea...

Страница 6: ...rly earthed In accordance with the provisions of SF Solar Fa brik GmbH Co KG it is not necessary to earth the module frames and rack for trouble free operation To avoid the risk of electric shock e g from static charges as far as possible SF Solar Fabrik GmbH Co KG recommends having the installer carry out professional earthing If an external lightning protection device is availab le a technical s...

Страница 7: ... detergents containing surfactants Avoid cleaning with strong acids alkaline solu tions petrol based cleaners steam and hot clea ners cleaners with silicone oils fluorides or waxes polishes alkaline cleaners and cleaners with scou ring agents and high pressure cleaners Ensuring comprehensive fire protection Under certain circumstances the installation of roof mounted systems can have an impact on ...

Страница 8: ...e year and unhin dered exposure to sunlight should be ensured for several hours even on days when the calendar is unfavourable Ensuring sufficient rear ventilation Sufficient rear ventilation ensures that performan ce reducing heat accumulation can be avoided Secure mounting In order to mount the modules as intended they must each be securely fastened by at least four points Framed PV modules may ...

Страница 9: ... guidelines of the inverter manufacturers Using suitable materials only The system may only be wired with special solar cables in accordance with DIN EN 50618 class 5 and suitable plugs It is of utmost importance that all materials used are in perfect electrical and mechanical condition Only use single core cables and select the appro priate conductor cross section to minimise the vol tage drop On...

Страница 10: ...72 cells Mono S2 HC 144 cells Mono S3 HC 144 cells Z B B Solar module Mounting clamped 6x P series B 150 350mm Z vert zentriert M series Mono S2 M series HC B 150 350mm Z vert zentriert Mono S2 HC Mono S3 HC P series 72 cells B 200 240mm or B 320 360mm Z vert zentriert M series 72 cells Mono S2 72 cells Mono S2 HC 144 cells Mono S3 HC 144 cells B B B B Solar module Mounting clamped 4x P series B 0...

Страница 11: ... is also important to ensure that the module is not connected to the generator field during operation The photoactive front side of the module should be covered as far as possible or face the ground during all work steps to keep the voltage low If all installation instructions are observed and the installation is carried out by a technical specialist the product guarantee of the modules remains in...

Страница 12: ...lated by the Electrical and Electronic Equipment Act ElektroG which transposes the WEEE Direc tive into German law Please also observe country specific regulations It is possible that notification is required in the res pective country Note on liability and status of the instructions If there are deviations from the instructions con tained in this user information SF Solar Fabrik GmbH Co KG does n...

Страница 13: ...13 Solar module mounting instructions Mono S3 Mono S2 M series P series 3 Notes ...

Страница 14: ...ment Nr 2004M01 E Solar modules SF Solar Fabrik GmbH Co KG Im Gewerbegebiet 12 63831 Wiesen Germany Phone 49 0 6096 97007 90 Fax 49 0 6096 97007 28 E Mail info solar fabrik de Internet www solar fabrik de REFERENCE PROJECT ...

Отзывы: