Operating Instructions and Installation Guide
Wall Mounted Split System
_______________________
Page 31
2.2 Indoor Unit Installation
Wrap the insulation material around the connecting
portion.
1. Overlap the connection pipe heat insulation and the
indoor unit pipe heat insulation material. Bind them
together with vinyl tape so that there may be no gap.
2. Wrap the area which accommodates the rear piping
housing section with vinyl tape.
3. Bundle the piping and drain hose together by wrapping
them with cloth tape over the range within which they
fit into the rear piping housing section.
4. Reroute the pipings and the drain hose across the back
of the chassis.
Installing Unit
1. Remove the spacer.
2. Ensure that the hooks are properly seated on the
installation plate by moving it left and right.
3. Press the lower left and right sides of the unit against
the installation plate until the hooks engage into their
slots (clicking sound).
g
ck