current position; 275W-H, compared to high current position). Usually, the same series of modules in the
same current position are required in accordance with the system design requirements.
d)
If the modules are color-coded and marked the corresponding logo on the carton due to the
customer requirements, when modules are taken out and stacked, they should be labelled to avoid
confusion. Usually the same row or the same square have the same colour according to the system
design requirements.
e)
Due to the complexity and differences of the construction sites, these precautions may not cover
all items, please refer to the specific construction standards.
3.3 Installation Safety
3.3.1 Wear protective clothing such as head gear, insulating gloves, safety shoes as prescribed by
local safety codes. Use insulated tools when installing the modules.
3.3.2 Do not install the modules in heavy rain, snow, or otherwise wet or windy conditions.
3.3.3 Completely cover the PV module surface with an opaque material during PV module installation
and wiring to prevent accidental charge build-up.
3.3.4 Plug in connectors tightly when working on wiring.
3.3.5 Due to the risk of electrical shock, do not perform any work if the terminals of PV module are wet.
3.3.6 Do not touch the terminal box and the end of output cables (connectors) with bare hands.
3.3.7 Do not unplug the connector under load.
3.3.8 Do not work alone.
3.3.9 Wear a safety harness if working far above the ground.
3.3.10 Do not wear metallic jewellery, which can cause electric shock, while installing or
troubleshooting the PV system.
3.3.11 Follow the safety regulations for any and all other system components, including wires, connectors,
charging regulators, batteries, inverters, etc.
3.3.12 Do not expose wires to direct sunlight. Use UV-resistant cables.
3.3.13 Do not damage the surrounding PV modules or mounting structure when replacing a PV module.
3.3.14 Do not change any PV module components (diode, junction box, connectors, etc.).