INSTALLATION AND OPERATION MANUAL SolahartXXXBLK – AU
INSTALLATION AND OPERATION MANUAL SolahartXXXBLK – AU
13
12
DANGER
! Risk of fatal injury due to electric
shock!
Ä
Block off the installation zone.
Ä
Keep children and unauthorized
individuals away from the solar power
system.
DANGER
! Risk of fatal injury due to electric
shock!
Ä
Ensure that modules and tools are not
subject to moisture or rain at any time
during installation.
WARNING
! Risk of injury due to falling mod-
ules!
Ä
Secure modules during installation.
Ä
Do not install modules in windy or wet
weather.
DANGER
! Risk of fatal injury due to electric
shock!
Ä
Only use dry, insulated tools.
Ä
Do not carry out the installation alone.
•
Only install undamaged modules and
components.
Ä
Do not modify the module (e.g. do not
drill any additional holes).
3.2 Preparation of installation
3 INSTALLATION
Ä
Maintain an interval of at least 10 mm
between two modules along the short
side and 5 mm along the long side.
10 mm
5 mm
EU
Option 2:
Ä
Install the module at the 4 mounting
points, see Fig. 2, p. 7.
Ä
Tighten clamps according to
manufacturer’s instructions.
NOTE
! Module damage may occur!
Ä
Do not subject modules to mechanical
tension. Max. torsion 10 mm/m.
Option 3:
Ä
Install the module using mounting
profiles, seeFig. 2, p. 7.
Option 1:
Ä
Fasten the module with 4 clamps
in the specified clamping range,
see Fig. 2, p. 7.
Ä
Tighten clamps according to
manufacturer’s instructions.
3.3 Module installation
3 INSTALLATION