31
SOWING ELECTRONIC CONTROL
Select the sequence of runs
1-
Push
and release for choosing between
the type of sequence and the sequence of runs.
The third and fourth digits indicate the sequence of runs.
2-
Push
and hold for choosing between sequence 1
and 15.:
Fig. 78
8.6 TURBINE ROTATIONAL SPEED/
TURBINE ALARM - C4
Visualization of turbine rotational speed
Select channel 4 by means of the central button
Turbine speed alarms
The minimum turbine rotational speed can be programmed.
Alarms are deactivated under 2 Km/h.
Minimum turbine speed
1-
Select canal 4.
2-
Push
longer than 5 seconds and keep it pushed.
3-
Push
for changing the digit and the value as in the
previous cases. 3800 rpm. by default
4-
Stop pushing for going back to the normal position.
Select the amount of pulses per run in the turbine (2 by de-
fault).
NOTE
: THE AMOUNT OF IMPULSES PER RUN IN THE TURBINE
IS ALWAYS 2. USE THIS PROGRAMMING MODE ONLY IN CASE
OF ERROR.
1-
PUSH THE BUTTON
FOR NEUMASEM VERSIONS OR
FOR NEUMASEM PLUS WHILE THE MONITOR IS CON-
NECTED BY MEANS OF THE REAR SWITCH, FOR ENTERING
INTO PROGRAMMING MODE 2.
2-
PUSH THE BUTTON
FOR NEUMASEM VERSIONS
OR
FOR NEUMASEM PLUS FOR CALIBRATING THE
CHANNEL AND GO TO CHANNEL 4 (TURBINE).
3-
PUSH
FOR MODIFYING THE FLASHING DIGIT AND
KEEP PUSHING FOR MODIFYING ITS VALUE, (IT MUST
ALWAYS BE 2).
4-
STOP PUSHING FOR GOING BACK TO THE NORMAL POSI-
TION.
8.7 DISTRIBUTOR SHAFT - C5
Select channel 5 by means of the central button
.
When the shaft stops rotating, the alarm sounds with 5
non-stop whistles after 40 seconds. If it does not rotate, the
alarm is repeated each 30 seconds.
For deactivating the alarm, stop the engine and restart it.
This alarm is deactivated under 2 Km/h.
The shaft alarm can be deactivated by pushing the button
for more than 5 seconds in the selected channel. The
display shows «Off». In this case, the alarm is not activated
even if the engine stops and restarts.
8.8 HOPPER LEVEL ALARM - C6
When the seed level is under the sensor, the alarm activates
with 5 non-stop whistles and the display shows «
ALA
».
Activate and deactivate the hopper level alarm
1-
Select channel 6 with the button
.
2-
Push the button
continuously and ...
3-
Push the central button for selecting «
0
» (un-
plugged) or «
1
» (plugged).
4-
Stop pushing for going back to the normal posi-
tion.
Содержание A-6000/NS PLUS
Страница 38: ...38 DOSAGE CHART ...
Страница 40: ...40 GUARANTEE ...
Страница 41: ...41 NOTES 13 NOTES DATE NOTES ...
Страница 42: ...42 NOTES DATE NOTES ...
Страница 43: ...43 NOTES ...