Содержание S1K Series

Страница 1: ...Uninterruptible Power Systems S1K Series Instruction Manual ...

Страница 2: ......

Страница 3: ...0 Troubleshooting 11 8 0 Storage 11 8 1 Storage Conditions 11 8 2 Extended Storage 11 9 0 Software Interface 12 9 1 Power Monitoring Software 12 9 2 Interface Kits 12 9 3 Remote Port 12 10 0 Specifications 13 11 0 Registration Warranty 14 11 1 Product Registration 14 11 2 Warranty Information 14 While every precaution has been taken to ensure accuracy and completeness in this manual EGS Electrical...

Страница 4: ...tection against harmful interference in an industrial installation 1 1 Safety Precautions WARNING To prevent the risk of fire or electric shock install the UPS in a temperature and humidity controlled room free of conductive contaminants Operate the UPS only from a properly grounded earthed ac supply To reduce the risk of electric shock do not remove the cover as it has no user serviceable parts i...

Страница 5: ...t circuit current To reduce the risk of fire connect only to a circuit provided with 20 A maximum branch circuit overcurrent protection in accordance with the National Electrical Code ANSI NFPA 70 ATTention Turn off and unplug your UPS from the outlet and contact SolaHD Technical Support at 800 377 4384 if the power cord or plug is damaged liquid has been spilled on the UPS the fuse blows frequent...

Страница 6: ...eries Instruction Manual 6 2 0 System Description 2 1 Front Rear Panel S1K650 S1K850 S1K1200 S1K320 S1K520 S1K1500 1 2 3 4 5 4 Symbols not on S1K320 S1K520 S1K320 S1K1200 S1K1500 6 7 6 7 8 9 9 10 11 11 11 12 ...

Страница 7: ...1K520 and S1K1500 5 LED indicator The LED indicator indicates the UPS status The indicator is illuminated continuously when the UPS is supplying utility power to the loads The indicator flashes slowly about once every 2 seconds when the UPS is supplying battery power to the loads The indicator flashes rapidly about once every half second when the loads connected to the UPS exceed capacity For All ...

Страница 8: ...DB 9 RS 232 cable 1 RJ 45 cable 3 3 Optional Accessories S1K PMBRK Wall panel mount bracket kit Not applicable for Models S1K650 and S1K1500 4 0 Installation 4 1 Placement Install the UPS in a protected area with adequate airflow and free of excessive dust Do not operate the UPS outdoors 4 2 Connect to Utility Power To power up the UPS connect the ac input connector to utility power 4 3 Charge the...

Страница 9: ...t Use the self test function to verify both the operation of the UPS and the condi tion of the battery In normal utility power press the On Off Test button for less than 1 second to perform a self test function During the self test the UPS runs in Backup Mode If the UPS passes the self test it returns to Line Normal operation 5 6 Green Mode If a load of 20 watts is connected to the UPS and the ac ...

Страница 10: ...on 6 2 Low Battery rapid beeping For All Models In Backup Mode when the battery energy runs low the UPS beeps rapidly until the UPS shuts down from battery exhaustion or returns to Line Normal operation 6 3 Overload continuous alarm For Models S1K650 S1K850 and S1K1200 When the UPS is overloaded it sounds a continuous alarm Remove non critical loads from the UPS protected output outlets to elimina...

Страница 11: ...the UPS for at least 4 hours Other failure Call SolaHD Technical Support Continuous beep Overload condition Remove the non critical loads Red LED is illuminated Battery failure Call SolaHD Technical Support Technical Support For further assistance please contact SolaHD Technical Support at 800 377 4384 847 268 6651 or by e mail at solahd technicalservices emerson com 8 0 Storage 8 1 Storage Condit...

Страница 12: ...are exhausted and turning off the UPS Table 2 Remote Port PIN Configurations PIN Signals Description 2 Transmitted data TD RS 232 3 Received data RD RS 232 remote shutdown The UPS will shut down when a high RS 232 level is sustained on PIN 3 for 0 5 seconds NOTE This feature is not applicable for Models S1K320 S1K520 4 Data terminal ready DTR 12 V 5 Signal ground 6 Ac failure PIN 6 generates a hig...

Страница 13: ...if 9 to 25 of nominal is detected protection Unit Input Fuse or circuit breaker for overload short circuit protection Overload Protection UPS automatically shuts down if overload exceeds 105 of nominal at 20 seconds 120 at 10 seconds 130 at 3 seconds UPS auto matically shuts down if overload exceeds 110 of nominal at 60 seconds 130 at 3 seconds Short Circuit UPS output cuts off immediately or inpu...

Страница 14: ...08 00 00 04 30 60 00 11 45 00 06 00 00 10 00 00 08 00 00 05 00 00 04 30 70 00 08 15 00 04 30 00 08 00 00 05 30 00 04 30 00 02 15 80 00 06 00 00 03 30 00 06 00 00 05 00 00 03 30 00 01 45 90 00 04 45 00 02 15 00 04 00 00 04 00 00 02 00 00 01 30 100 00 04 00 00 01 45 00 03 00 00 03 00 00 01 30 00 01 00 notes Backup times are based on a fully charged battery 11 0 Registration Warranty 11 1 Product Reg...

Страница 15: ......

Страница 16: ...Part Number A272 067 Rev 14 January 2011 www solahd com 800 377 4384 847 268 6651 solahd technicalservices emerson com ...