![SOHARD SH-ARC PCI Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/sohard/sh-arc-pci/sh-arc-pci_manual_1312566010.webp)
SH-ARC PCI
Manual
Version 01.00
4 Interfaces
4.1 Coax Interface
Connector type: BNC jack, insulated
Pin Assignment:
Pin
Description
Meaning
1
Shield
Shield of coax cable
2
Center
Center of coax cable
4.2 RS485 Interface
There are two types of the SH-ARC PCI which differ in connector type
and pin assignment. Both are described below.
Important Notice
: In order to meet the CE specifications, the cable
connected to the SUB-D connector/jack must have a shielding braid,
which has to be connected to the connector with low impedance.
4.2.1
RS485-Interface according AUG (9 pin SUB-D male)
Assignment according AUG standard[5]
Connector type: 9 pin SUB-D male
Pin Assignment :
Pin
Description
Meaning
1
GND_SEL
Can be connected to AGND (S1=ON) and/or
GND_RS via S2. (see chapter Dip Switch
Settings)
2
nc
Reserved for additional power supply
3
DATA-B
Data line B (more negative than
DATA-A when in idle state)
4
nc
Reserved for direction control
5
GND_RS
Data reference potential, supply
6
+5V_RS
Isolated +5V Suppy for RS485 Interface. The
maximum Current must not exceed 25 mA.
7
nc
Reserved for additional power supply
8
DATA-A
Data line A (more positive than DATA-B when in
idle state)
9
nc
Reserved for additional power supply
Shield AGND
Shield
AGND is the bracket potential. GND_RS is the ground of the
electrically decoupled RS485 circuit.
page 10
Содержание SH-ARC PCI