SERVICE MANUAL
E04 ERROR
Fix Compressor Connections
Change The Compressor
Is There a
Disconnection Between
the e-card and the
compressor?
YES
YES
NO
NO
Is machine
power correct?
NO
Check the compressor gas
YES
Change the cable tree
User should be informed about
the machine.
YES
NO
Is connection
of compressor
connector
correct?
Are the measured
resistance values
through the compressor
connector correct?
E08 ERROR
Is the voltage in the
socket between
170-265 V?
Change The Main Board.
YES
Machine has not a failure, The power
line should be checked.
NO
BANDEAU
HP F2
Содержание BANDEAU HP F2
Страница 1: ...SECHE LINGE MANUEL DE SERVICE BANDEAU HP F2 ...
Страница 8: ...SERVICE MANUAL 7 1 1 Motor Measurements 1 2 3 2 1 3 3 1 2 BANDEAU HP F2 ...
Страница 10: ...SERVICE MANUAL 7 2 1 Pump Measurements 2 1 1 BANDEAU HP F2 ...
Страница 14: ...SERVICE MANUAL 7 5 1 Compressor Measurements 2 1 3 c r s r c s c s r BANDEAU HP F2 ...