Inputs
21
SW 5 DIP Switch Functions
The SW 5 DIP switch on the RM-4E is similar to the SW 3 DIP switch on
the RM-4.
Note
: On = Closed, Off = Open
TABLE 8.
SW 5 DIP Switch on RM-4E and SW 3 DIP Switch on RM-4
SW 5 DIP Switch
on RM-4E
Function
Value
Equivalent DIP
Switch on RM-4
SW 5-1
Reader Type
Off = Magnetic (ABA) signaling,
On = Wiegand signaling,
SW 3-1
SW 5-2
LED Control
Off = Normal,
On = One-Wire (A,B,C)
SW 3-6
SW 5-3
LED Control
Off = Normal,
On = External Bi-color
SW 3-3
SW 5-4
Tamper
Off = Normal Tamper,
On = Inhibit Tamper
SW 3-4
SW 5-5
RS-485 Termination
Off = Not last in line,
On = Last in line
SW 3-5
SW 5-6
Input 1 and Input 2
LED Control
Off = Do not display LEDs,
On = Display LEDs
N/A
SW 5-7
Not Used
Not Used
N/A
SW 5-8
Not Used
Not Used
N/A