13 • Control Keypad
________________________________________________________________________________________________
BTL-04/10/2006
MIP6-051006-Mb
Press
Mode
key to exit test/maintenance mode
6.5.3
Obtaining default parameters
Press
Page
and
T
keys simultaneously.
The LCD will display:
TEST / MAINTENANCE
******OPTIONS***********
Press
Select
key three times.
The LCD will display:
STORE NOW ?
DEFAULT SETTINGS
To obtain “default parameters” press
Page+Store
simultaneously.
The LCD will display:
DATA SAVED OK
At this point (If “default parameters” were obtained) the MIP-6 exit test/maintenance mode.
CAUTION!
Obtaining Default Parameters erases all previously modified settings and
requires the operator to program all parameters values again.
6.5.4
Clear statistical data
Press
Page
and
T
keys simultaneously.
The LCD will display:
TEST / MAINTENANCE
******OPTIONS***********
Press
Select
key four times.
The LCD will display:
CLEAR NOW ?
STATISTICAL DATA
To clear “statistical data” press
Reset+Store
simultaneously.
The LCD will display:
DATA SAVED OK
At this point (If “statistical data” is cleared) the MIP-6 exit test/maintenance mode.
6.5.4.1
Data cleared when STATISTICAL DATA is reset.
The following data is cleared when STATISTICAL DATA is cleared:
•
Total measure time
•
Total # of trips
•
Min. Insulation Resistances (general and of present month)
•
Max. Insulation Resistances (general and of present month)
•
Pre Trip Insulation value
•
Last Trip
•
Last Alarm
•
Previous trips information and time stamps
•
Hour, Date, Month, Year arrays with Insulation resistance history !
CAUTION!
After clearing statistical data it is not possible to retrieve any cleared values.