Страница 1: ...M MI IP P 6 6 M Mo ot to or r I In ns su ul la at ti io on n P Pr ro ot te ec ct ti io on n I In ns st tr ru uc ct ti io on n M Ma an nu ua al l Ver 23 03 09...
Страница 2: ...al actions performed by the key pad 12 6 5 1 Run self test 12 6 5 2 Obtaining software version 12 6 5 3 Obtaining default parameters 13 6 5 4 Clear statistical data 13 6 5 4 1 Data cleared when STATIS...
Страница 3: ...adio interference in which case the user may be required to employ additional mitigation methods 3 Utilization category is AC 53a or AC 53b Form 1 For further information see Technical Specification 2...
Страница 4: ...m and user safety maximum DC voltage is 50V Insulation measurement range is 0 50Mohm for both low voltage and medium voltage types The MIP 6 measures the insulation level when the motor is off line Me...
Страница 5: ...e a very flexible package All output relays can be programmed as TEST COMMAND OFF M V units only TEST COMMAND ON M V units only INS TST NOT ACT INS TST ACTIVE INSUL IN RANGE D INSUL IN RANGE C INSUL I...
Страница 6: ...when real time clock option is installed 3 7 Optional serial link communication The MIP 6 is equipped with an optional powerful data communication system This communication system is unmatched in its...
Страница 7: ...utput is an isolated output Use shielded twisted pair for analog output It is recommended to ground the shield of the analog output cable at the receiver side 3 All output relays are programmable Refe...
Страница 8: ...analog output It is recommended to ground the shield of the analog output cable at the receiver side 3 All output relays are programmable Refer to section 6 9 2 page 20 for more details 4 All input r...
Страница 9: ...Common of output relays A B C D Terminal 16 Common of output relay E Terminal 17 Output relay E N C Terminal 18 Output relay E N O Terminal 19 Common of output relay F Terminal 20 Output relay F N C T...
Страница 10: ...um Voltage use terminals 51 and 52 Terminal 51 is used for the insulation measurement and terminal 52 is used for the line test Both terminals should be connected to motor via resistors unit RU7 13 It...
Страница 11: ...d programming menus available in the MIP 6 Allows the operator to select a function within each Page Note Pressing Select continuously changes shown parameters continuously Allows the operator to incr...
Страница 12: ...g parameters Press Page key several times until you reach the required Mode page Press Select key to review parameters of this Mode When reaching the required parameter modify its values with T or S k...
Страница 13: ...ameters values again 6 5 4 Clear statistical data Press Page and T keys simultaneously The LCD will display TEST MAINTENANCE OPTIONS Press Select key four times The LCD will display CLEAR NOW STATISTI...
Страница 14: ...s for the hour settings to seconds day month and year settings After Store key is pressed last time the LCD will display DATA SAVED OK At this point the MIP 6 exit test maintenance mode NOTE For longe...
Страница 15: ...is found during store process then next message is shown STORAGE ERROR Displayed when an error is found in the store process WRONG PARAMETERS Displayed after power up if the non volatile parameter ch...
Страница 16: ...MONTH AVG 34566 KOHM INSUL ALARM DLY 10 MIN CONFIG INPUT E EXT FAULT 1 N O FRONT COM ADDRES OFF THIS MONTH MIN 12345 KOHM INSUL RANGE A 4 0 MOHM CONFIG INPUT F EXT FAULT 2 N O STORE ENABLE COMM PARAM...
Страница 17: ...e 26 See page 27 See page 27 See page 28 Display Display Display Display Display PREVIOUS INSUL AVARAGE VALUES PREVIOUS INSUL AVARAGE VALUES PREVIOUS INSUL MONTH YEAR PREVIOUS INSUL MONTH YEAR LAST AL...
Страница 18: ...r Note In order to be activated this parameter must be programmed to I O PARAMETERS SETTINGS Parameters CONFIG OUTPUT X Refer to section 6 9 2 page 20 for more details TRIPPING ALARM OPTIONS Refer to...
Страница 19: ...ividually by pressing Store key after modifying the parameter When parameters are correctly stored the LCD will read DATA SAVED OK This concludes INSULATION PARAMETER settings Pressing Select key afte...
Страница 20: ...RESET is programmed to remote reset the MIP 6 To remote reset close contact momentarily TEST LINE is programmed to start the wiring test of the cable from the resistor unit RU7 RU13 Close the contact...
Страница 21: ...2 is programmed to close the contact when the insulation level is below insulation level programmed as RANGE D INSUL IN RANGE C 2 same as INSUL IN RANGE D but for RANGE B INSUL IN RANGE B 2 same as I...
Страница 22: ...ot optional OUTPUT DELAY 120 SEC 0 3600sec Sets delay time for OUTPUT F relay ANALOG OUT TYPE 4 20 mA 4 20 Ma 0 20 mA Sets the type of the analog output ANALOG OUT PARAM INS RES AVG 1H INS R AVG 1MNTH...
Страница 23: ...pping alarm relays Notes 1 All protections MUST be programmed in this page in order to be operative 2 Each of the faults listed below can be programmed as DISABLED or ENABLED 3 The table below shows f...
Страница 24: ...LINK NO Available only when Communication option is installed S LINK PAR SAVE DISABLE ENABLE DISABLE When set to DISABLE it prevents parameter setting through serial link communication When set to EN...
Страница 25: ...0kOhm THIS MONTH MAX 4321 KOHM Displays the maximum measured resistance of this month Range 0kOhm 60000kOhm MINIMUM INSUL R 34521 KOHM Displays the minimum resistance measured since last reset To rese...
Страница 26: ...MOHM Previous hour data Range 0 60MOhm HOUR 52 6 MOHM Display 19 more screens to complete 24 screens with hours data showing average insulation values for HOUR 22 to HOUR 4 Range 0 60MOhm 6 9 7 Last...
Страница 27: ...he display shows a scrolling screens with previous months data Range 0 60MOhm 03 00 AVG MIN MX 60 0 60 0 60 0 M Previous month data Range 0 60MOhm 02 00 AVG MIN MX 60 0 60 0 60 0 M Previous month data...
Страница 28: ...INTERNAL FAILURE Displays last active fault that was enabled as a trip LAST ALARM INTERNAL FAILURE Displays last active fault that was enabled as an alarm PRE TRIP INSUL 0 KOHM Displays values of ins...
Страница 29: ...29 Case and Cutout Details 7 CASE AND CUTOUT DETAILS 86 4 107 Cut Out 92 138 144 96 ________________________________________________________________________________________________...
Страница 30: ...30 Rear Panel Connection ________________________________________________________________________________________________ 8 REAR PANEL CONNECTION 9 RESISTOR UNITS RU 7 RU13 DIMENSIONS...
Страница 31: ...switch Tests both external and internal connections and wiring and electronic circuitry LV Insulation Resistance Input terminal 53 Method Off Line Does not measure when mains is connected Can be conn...
Страница 32: ...50 60Hz Notes 1 MIP MV1 is supplied with a resistor unit RU 7 2 MIP MV2 is supplied with a resistor unit RU 13 Options Specify Description 0 No options M Communication RS 485 MODBUS Rear connection 5...