Configuration of the WB169-430 module

Configuration parameters of the WB169-430 module can be displayed and changed from the common computer
(PC) by one of these methods:

- with using of

USB-CMOS”

converter and configuration cable connected to the module;

- wirelessly, with using of

USB-IRDA”

or

BT-IRDA”

converter;

Technique of interconnection of the module with configuration computer and general rules of configuration are
described in detail in the chapter 2 of

Configuration of wacoSystem product family devices”

, that can be

downloaded from the producer website:

www.wacosystem.com/support/
www.softlink.cz/en/documents/

The description and meaning of all configuration parameters that can be checked and changed by cable can be
found in the section

3.1

Setting of WB169-430 parameters via configuration cable”.

Description of interconnection of the converter with PC (

USB-IRDA”) or smartphone (

BT-IRDA”) and gen-

eral rules of configuration with using of

optical converters

are described in the chapter 3 of above mentioned

manual

Configuration of wacoSystem product family devices”. The description and meaning of the parameters

that can be changed by optical converter can be found in the section

3.2

Setting of parameters by using of optical

IRDA” converter”.

3.1

Setting of WB169-430 module parameters by configuration cable

In following part of the document there is a description of these parameters of the WB169-430 module, that can be
displayed and examined from PC connected to the module by configuration cable. Some of the parameters can be
changed by configuration commands entered

from the console”.

3.1.1

List of WB169-430 module configuration parameters and commands

List of all configuration parameters of the module can be displayed by entering of

”show”

command and pressing

of

ENTER” key. The following list of parameters will display in the terminal window:

mon#show
----- Configation -----

Timezone : 1
MBUS ID : 00900011
MBUS version : 6
MBUS manufacturer : SFT
MBUS medium : 7
MBUS power : 3 (20 dbm)
MBUS mode

: N1

WMBUS channel : 3 - 169,43125 Mhz
Send periode : 30
Sensus meters :

ID[0] : 130551476
ID[1] : 130551474
ID[2] : 130551477
ID[3] : 130551475
ID[4] : 130551473

Data will be encrypted by AES
Next send : 29 min.

No. sent : 1 msg(s)
No. recv : 0 msg(s)

Conf. version : 7
SW version 1.02, date Jul 31 2020

mon#

WB169-430

4

Содержание WB169-430

Страница 1: ...WIRELESS COMMUNICATION SYSTEM Wireless M Bus WB169 430 Revision 1 0 SOFTLINK s r o Tomkova 409 278 01 Kralupy nad Vltavou Czech Republic Phone 420 315707111 e mail sales softlink cz www softlink cz...

Страница 2: ...information message 18 3 3 2 Alarm message 20 4 Operational conditions 21 4 1 General Operation Risks 21 4 1 1 Risk of mechanical and or electric damage 21 4 1 2 Risk of premature battery discharge 21...

Страница 3: ...list of watermeters in reach acquired by RADAR function 16 5 View of WB169 430 module information message received by WMBUSAN4 analyzer 19 6 Encrypted and decrypted message of the WB169 430 module 19...

Страница 4: ...e used as a local communication gateway for remote reading of Sensus iPERL series watermeters The module receives regular radio messages with readings Bubble Up messages from watermeters in its radio...

Страница 5: ...it must be ordered separately The module is power supplied by internal battery with up to 8 years lifetime for frequency of 6 broadcastings per day Battery lifetime can be negatively influenced by sho...

Страница 6: ...32 Transmission speed 9600 Baud Operation mode asynchronous Transmission parameters 8 data bits 1 stop bit none parity Signal level TTL CMOS Optical configuration interface Transmission speed 115 200...

Страница 7: ...f wacoSystem product family devices The description and meaning of the parameters that can be changed by optical converter can be found in the section 3 2 Setting of parameters by using of optical IRD...

Страница 8: ...period in minutes mode Set WMBUS mode 1 N1 2 N2 chan Set WMBUS channel type for help ekey Set encrypt key W MBUS point no encrypt skey Set encrypt key Sensus sid index value Set Sensus meter ID Modem...

Страница 9: ...to the saved set ie there are no differences between commands in FLASH and in the operating set the module will report prompt in the format mon If operating configuration was changed so that it no lon...

Страница 10: ...standard each type and modification of the device could have its own line of serial numbers The code is read only type for the WB169 430 module and cannot be changed Assigned version number can be dis...

Страница 11: ...g power chan frequency channel mode communication mode and ekey encryption key commands is intended for setting of module RF subsystem parameters The command Power is used for adjusting of the module...

Страница 12: ...kbps 3 chan 2a 169 43125 Mhz 2 4 kbps The command Encryption key is used for setting of the encryption key for an encryption of transmitted messages by using of AES 128 key The encryption key of 16 by...

Страница 13: ...etting of reading data from Sensus iPERL watermeters There are following commands skey setting of encryption key for decrypting of watermeter messages recvwin open 433 MHz receiving window for preset...

Страница 14: ...eter with 130551477 serial number into the list of read meters under index 4 cfg sid 4 130551477 Sensus ID 4 changed from 0 to 130551477 mon Current list of read watermeters is stated in the list of a...

Страница 15: ...ns command can be used for displaying of current values of A D converters measuring battery voltage and processor temperature This command is intended only for module checking and diagnostics cfg sens...

Страница 16: ...of FLASH memory In the SW version row there is a module software version and release date 3 2 Setting of parameters by using of optical converter The module i equipped with the IRDA infrared optical...

Страница 17: ...M Bus identification the default value of the Medium parameter is 07 Water More detailed description of the variable and possibilities of its setting are explained in details in section 3 1 4 Commands...

Страница 18: ...iables WMBUS Mode WMBUS Channel and WMBUS Power are used for settings of radio frequency subsystem of the module More detailed description of these variables and possibilities of their setting are exp...

Страница 19: ...t of watermeters in reach acquired by RADAR function As evident from the pictures the application enables performing of following settings setting of list of watermeters to be read setting of transmit...

Страница 20: ...s from reset read only 14 No recv curr status No of received messages from reset read only 15 Conf version curr status No of stored images since last FLASH erasure read only 16 SW version curr status...

Страница 21: ...gnalizes low battery volatge item Signature contains encryption type and parameter 00 00 means no encryption If the message has been re transmitted repeated item Signature is modified by Wireless M Bu...

Страница 22: ...ncryption the total number of data block bytes must be rounded into integer multiple of 16 Byte i e 16 32 48 64 etc Bytes Rounding of the message is performed by inserting of required number of 2F blo...

Страница 23: ...r more other segments carrying additional information relevant to the alarm typically current status in time of its arising Event of RESET type is always followed by one variable of of Reset Code type...

Страница 24: ...ation It is recommended to lead antenna and signal cables as far from 230 50 Hz power cables as possible 4 1 2 Risk of premature battery discharge The devices are equipped with the long duration batte...

Страница 25: ...ecommended storing the modules with batteries disconnected and activate the battery during mounting with exception of modules with additional sealing by silicon filling see paragraph 4 2 4 4 Safety pr...

Страница 26: ...the module to a suitable firm object wall pipe by two screws or by a clamping tape There are mounts by the box sides for the attachment The recommended position of the mounted module is in the way th...

Страница 27: ...le mechanical damage The radio signal conditions can be estimated empirically on the base of previous experience or examined by measuring of the signal strength by the reference transmitter receiver 4...

Страница 28: ...after each repair and replacing of the module it is recommended to check functionality of its broadcasting with using of common Master receiver RF analyzer or any other convenient device If the WB169...

Страница 29: ...of all broadcasting data i e readings processor temperature and battery voltage If some of the parameters goes beyond the common steady value it is recommended to contact the installation site caretak...

Страница 30: ...gnal caused by construction works or any construction changes within the premises or by operation around the installation site moving of machines cars etc permanent periodical or occasional interferen...

Страница 31: ...module subsystems in following order check correctness of setting of the module in the central system database check functionality of power supplying as described in the paragraph 5 1 1 Power supplyi...

Страница 32: ...ss M BUS WM868 WACO WS868 Sigfox or NB NB IoT series of the modules can be found on the manufacturer website www wacosystem com www softlink cz If interested in any additional information related to a...

Отзывы: