After expiring of [time] period the ”RADAR” table content can be browsed by using of
”radar”
command:
mon#radar
Show radar :
id 130551474, rssi -75, time 2019-01-01, 0:01:25+01
id 130551473, rssi -69, time 2019-01-01, 0:01:21+01
id 130551476, rssi -69, time 2019-01-01, 0:01:17+01
id 130551477, rssi -54, time 2019-01-01, 0:01:13+01
id 130400388, rssi -103, time 2019-01-01, 0:01:12+01
id 130551475, rssi -62, time 2019-01-01, 0:01:11+01
mon#
As evident form the example, during the receiving window the module received messages from six Sensus iPERL
watermeters. Each record contains watermeter serial number (id), radio-signal strength in dB (rssi) and message re-
ceiving time (time). Stored values come from the first received message from the watermeter in the receiving window.
The
”Set Sensus meter ID”
variable serves for setting of list of Sensus iPERL watermeters, that is intended to
be read by the WB169-430 module. Each record to the list could be created by using of
”sid [index] [value]”
command, where meter ID (serial number) is linked with meter index (0 - 9).
Example of command for entering of iPERL watermeter with ”130551477” serial number into the list of read meters
under index ”4”:
cfg#sid 4 130551477
Sensus ID[4] changed from : 0 to : 130551477
mon#
Current list of read watermeters is stated in the list of all configuration parameters. The list can be also displayed
by using of ”sid” command without parameters:
mon#sid
Sensus ID[0] : 130551475
Sensus ID[1] : 130551473
Sensus ID[2] : 130551474
Sensus ID[3] : 130551476
Sensus ID[4] : 130551477
mon#
3.1.7
Commands of
”
Utils” group for setting of module common functions
This group of commands is intended for control and setting of other common functions of the module. There are
following commands:
tz
setting of time zone (UTC + n)
time
real time (RTC) displaying/setting (hh:mm:ss)
date
real time (RTC) displaying/setting (RR.MM.DD)
uptime
show system uptime from last reset
sens
show current values of internal sensors (temperature, voltage..)
send
immediate sending of radio message
sendp
immediate sending of series of radio messages
reset
command for module reset
?
show list of configuration commands (
”
Help”)
By using of
”tz”
command the current
Time Zone
can be preset. The module supports
only one
time zone, that
is set in number of hours from UTC.
Example of setting of ”UTC+1” Time Zone (Central-European Time):
cfg#tz 1
Tz change from 0 to 1
cfg#
WB169-430
11