background image

Chapter 3 - PBpro ETH Adm inistration

PBpro ETH - User Guide

23

3.3.4.1 Web based configuration and firmware update

After an IP connection between PC and PBpro ETH has been set up as described in the
previous sections, you may access the PBpro ETH from your PC by means of a Web
Browser (e. g. Microsoft Internet Explorer).

Start your browser with the URL http://192.168.212.212 (factory default for Ethernet
connection) or the currently assigned IP address of the PBpro ETH respectively. The
page 

System Status

 will be displayed. The menu bar offers four information pages, four

configuration pages and the contact page.

The configuration pages offer the following functions

Network Configuration

Device Configuration

Firmware Update

Set Password

All configuration pages require a login name and a password to execute the functions. The
login name is "config". The password is "config" by default, but may be changed.

3.3.4.2 Network configuration

The PBpro ETH is shipped with the following default IP configuration:

Login:

config

Password:

config

Host Name:

<part number>-<serial number> (see type label)

IP Address:

192.168.212.212

Subnet Mask:

255.255.255.0

Maintenance IP Address:

192.168.212.231 (for future use only)

You may change the IP configuration according to your needs. IP address and subnet
mask must be present in any case. You may leave the host name empty. It is reserved for
future use and has no meaning in the current release. It is not necessary to configure a
default gateway, if the computer and the PBpro ETH device are connected to the same
subnet.

Содержание PBpro ETH

Страница 1: ...Copyright 2014 Softing Industrial Automation GmbH Remote PROFIBUS Interface PBpro ETH User Guide Version MMA NN 012310 E 072014 02...

Страница 2: ...r improvements to these instructions without prior notice The actual design of products may deviate from the information contained in the instructions if technical alterations and product improvements...

Страница 3: ...ROFIBUS interfaces 10 2 5 Ethernet port 10 2 6 Light Emitting Diodes LED Chapter 3 12 PBpro ETH Administration 12 3 1 Built in web server 13 3 2 PBpro ETH information 13 System Status Information 3 2...

Страница 4: ...te 3 3 4 4 26 Set password 3 3 4 5 26 Configuring access to PBpro ETH on a Windows PC 3 3 5 26 Install software 3 3 5 1 26 Configure driver 3 3 5 2 30 Reset to factory settings 3 3 6 Chapter 4 32 Tech...

Страница 5: ...n the housing of the PBpro ETH It does not contain any parts that need to be maintained or repaired by the user In the event of a fault or defect return the unit to the vendor Opening the unit will vo...

Страница 6: ...itten in italic Device description files are located in C StarterKit delivery software Device Description files CAUTION CAUTION indicates a potentially hazardous situation which if not avoided may res...

Страница 7: ...s complete and free of defects In case of problems please contact your vendor 1 5 Intended Use The PBpro ETH has been designed for use in factory process and building control The unit must not be used...

Страница 8: ...control cabinets The PBpro ETH is convection cooled It therefore needs to be installed in such a way that the ventilating ducts are at the top and bottom of the unit Ensure a ventilation space of at l...

Страница 9: ...blows if an overvoltage of approx 30 V or higher occurs in the power supply or if a fault occurs in the device The safety fuse can only be replaced by the device manufacturer Important The starting c...

Страница 10: ...es the power supply status This LED is on when the internal power supply is ensured If this LED is off the supply voltage 24 V is missing or the internal voltage generation is defective In the latter...

Страница 11: ...e PB LED shows the bus activity of the corresponding interface Master The LED is on as soon as the master has received the token Slave The LED indicates the status data exchange Note The LED may also...

Страница 12: ...ing the DHCP discover procedure The default hostname is composed of part number serialnumber e g http DEA NN 012314 133500005 Part number and serial number can be found on the type plate of the PBpro...

Страница 13: ...ETH consisting of MAC Address fixed Ethernet MAC address IP Address IP address Subnet Mask IP subnet mask Broadcast Address IP broadcast address Default Gateway Address address of the IP gateway to ot...

Страница 14: ...14 PBpro ETH User Guide 3 2 2 Hardware Diagnostics During start up of the device several hardware components of the system are tested The test result is shown in the following example Figure 3 Hardwar...

Страница 15: ...l PROFIBUS interface for the first channel and up to three additional PROFIBUS modules for its multi channel veraiants All componentns as well as the entire device are identified by serial numbers and...

Страница 16: ...mask and gateway IP address must be set accordingly This information is referred to as IP configuration The IP configuration can be changed via Ethernet by means of a Web Browser HTTP protocol or by t...

Страница 17: ...he following IP ports Port 80 for HTTP PBpro ETH s web pages Port 2355 for discovery and configuration using the tool Search and Configure Port 2356 for controlling PBpro ETH using TCP IP sockets Port...

Страница 18: ...18 PBpro ETH User Guide Figure 6 Search and Configure Devices By selecting the device and clicking Configure you can modify network parameters of the PBpro ETH without using its website Figure 7 Searc...

Страница 19: ...overall network allowing data exchange between any two network stations in any two subnetworks The physical characteristics of the networks or of the transmission paths Ethernet Token Ring ISDN are of...

Страница 20: ...notation the part of the subnet mask which corresponds to the net ID is filled with 1 digits the part corresponding to the host ID is filled with 0 digits Example of a subnet mask is 255 255 255 0 Wit...

Страница 21: ...description below explains the establishment of a TCP IP connection to your PBpro ETH Such a connection makes it possible to change the preconfigured IP address of the PBpro ETH 1 Ask your network ad...

Страница 22: ...address the subnet mask and the standard gateway address are shown To add a second IP address click the Advanced button f Click Advanced to add a second IP address Then click Add in the IP Addresses d...

Страница 23: ...Configuration Device Configuration Firmware Update Set Password All configuration pages require a login name and a password to execute the functions The login name is config The password is config by...

Страница 24: ...o ETH will be lost You have to use the new IP address to reestablish web access to the Pbpro ETH If an inconsistent network configuration is used it may be impossible to connect to the PBpro ETH again...

Страница 25: ...the change process is indicated by the message Success in the browser window 3 3 4 4 Firmware update If a new version of the device s firmware becomes available it can be stored in the device using th...

Страница 26: ...on a Windows PC 3 3 5 1 Install software The PBpro ETH software is part of the PBpro ETH Installation CD 1 Insert the CD into your CD drive 2 If Autorun is enabled on your system the startup page is...

Страница 27: ...ministration PBpro ETH User Guide 27 2 Select PBproETH FG series and click Add Figure 10 Device Configuration 3 A dialog is opened allowing to enter modify symbolic naming of a PROFIBUS channel Figure...

Страница 28: ...e default name Node n according to your needs 5 Click Next 6 In the next step you need to identify the the PBpro ETH either by its IP address or by its host name and select the assigned connection For...

Страница 29: ...e control interval for monitoring the connection establishment to the PBpro ETH Max Idle Time Time control interval to monitor the connection DP Update Interval Update interval time for exchanging the...

Страница 30: ...tion programs either via its symbolic name e g Node0 or via its unique interface number Examples for ready to use software are Softing s PROFIdtm free gateway DTM for FDT based parameterization and as...

Страница 31: ...n also lead to permanent failure of the PBpro ETH Such damages are not covered by warranty To reset proceed as follows 1 Remove power from the PBpro ETH 2 Carefully insert the tip of a ball pen into t...

Страница 32: ...tself DEA NN 012311 DEA NN 012312 DEA NN 012313 DEA NN 012314 Supply Voltage direct current 24V DC Supply Voltage Tolerance 20 incl ripple Typical Current Consum ption During Operation 0 2 A 0 3 A 0 4...

Страница 33: ...nents of your installation DC adapter Industrial Ethernet devices etc also have to meet the EMC requirements A shielded cable must be used In addition the cable shield must be grounded properly CAUTIO...

Страница 34: ...Chapter 5 Declarations by the manufacturer 34 PBpro ETH User Guide WEEE Electrical and electronic equipment must be disposed of separately from normal waste at the end of its operational lifetime...

Страница 35: ...This page is intentionally left blank...

Страница 36: ...r Allee 6 85540 Haar Germany Tel 49 89 4 56 56 0 Fax 49 89 4 56 56 488 Internet http industrial softing com Email info automation softing com Support support automation softing com Softing Industrial...

Отзывы: