Softing CableMaster CM500 Скачать руководство пользователя страница 1

1

CableMaster 

CM500

Voice, Data & Video Tester with

Length Measurement

•  Tests Voice (6 wire), Data (8 wire) and Video 

(coax)

•  Easy to read, extra large 7-segment LCD 

screen with large icons

• 

Tone generation over voice, data and video 

cables, with 4 different tones

• 

Measures length of entire cable and 

individual wire pairs

•  RJ (Voice & Data) master remote stores in 

bottom of case

• 

Maps 19 locations at one time

• 

Tests and indicates pins with shorts,

 

opens, reversals, miswires and split pairs

• 

Displays “Pass” icon for correctly wired 

T568A/B and crossover/uplink

• 

Displays “Pass” icon for correctly wired 

6-pin telephone plus “Rev” for reverse-

pinned

• 

Low power consumption for long battery 

life

• 

Auto power-off

USER MANUAL

Содержание CableMaster CM500

Страница 1: ...nes Measures length of entire cable and individual wire pairs RJ Voice Data master remote stores in bottom of case Maps 19 locations at one time Tests and indicates pins with shorts opens reversals mi...

Страница 2: ...ns 8 Using the Tester 10 Cable Testing 12 Remotes 14 Interpreting Test Results 15 Video Coax Cables 16 Voice POTS Cables 16 Set Up Menus 17 Setting the Cable Capacitance 18 Pass Fail Settings 18 Singl...

Страница 3: ...est Measure and Map data coaxial video and voice cables Fault testing for opens shorts mis wires reverses and split pairs Highly accurate length opens and split detection using capacitive technology P...

Страница 4: ...adapter with an RJ45 on one end and an RJ45 jack on the other is highly recommended to extend the life of the jack Only insert RJ45 connectors into the RJ45 jack in the tester Plugging 6 position con...

Страница 5: ...eMaster 500 Parts 1 Connector ports and built in LED flashlight top of tester 2 Large Backlit LCD Screen 3 Glow in the Dark Keypad 4 Stored Master Remote Removable with RJ45 RJ12 11 and Female Jacks 1...

Страница 6: ...Tone Mode PASS FAIL Port Link Mode Cross over Wire Map Fault s Detected Remote ID Up to 20 Shield Detec on Length or Cable Capacitance Value High Voltage Warning Feet or Meters Se ngs Menu Beep On Ba...

Страница 7: ...rs are in contact with each other at a point in the cable Rev Wires are reversed Split A wire in one pair is switched with the wire of another pair X Over Cross over cable detected ID no ID number for...

Страница 8: ...Short on 4 5 Remote 1 35 3 ft FAIL Data Cable STP Open on 4 5 Remote 1 35 3 ft FAIL Data Cable STP Split on 4 5 and 7 8 Splits always affect at least 2 pairs 35 3 ft FAIL Data Cable STP Mis wire on 4...

Страница 9: ...ended test Split on 4 5 and 7 8 shielding not tested 35 3 ft FAIL Data Cable STP Cross over detected 35 3 ft Tester set in ANY Cable mode TONE mode Hi Lo warble Tone On Port Link Blink Mode Blink On...

Страница 10: ...rmally being the same as the top line for a one to one wired cable If there is a mis wire Fig 3 the pin numbers on the second line will indicate the pin numbers detected and the Fail icon will appear...

Страница 11: ...icons are on a new test is in progress In the coax mode the Open Short or Pass icon will be appear to indicate the results of a test If the cable passes the ID icon will be appear as well as a remote...

Страница 12: ...st keys resume testing automatically returns after 5 seconds of no activity The LEN Auto setting measures the first pin pair it can find without a short or other detected problem The CableMaster 500 a...

Страница 13: ...change the pair slection to the following options Data Cables AUTO LENGTH measures the length of the first pin pair that doesn t have a fault e g not shorted In most cases for a data cable that is goo...

Страница 14: ...are used for fault testing Data or Telephone cables They also have unique ID numbers and are used to map the end location of the cable Test remote IDs are shown in the tester display with a hyphen e...

Страница 15: ...ble is properly connected at both ends UTP appears if there is no end to end continuity in the shielding detected Short It will be flashing if there is a short to a wire in the cable along with that p...

Страница 16: ...results The CableMaster 500 assumes the 6 position jack on the main unit and the remote will be used for connecting the tester to the cable run to be tested This mode uses the 3 pair USOC standard to...

Страница 17: ...will test the cable for a standard TIA568 configuration and display UTP if no continuous shield is detected or STP if a continuous shield is detected It is likely that you will use this setting for mo...

Страница 18: ...al Single Ended Testing If no test remote or mapping ID is found a single ended test is performed on the open cable A single ended test first measures the length of all 8 wires If all wires are greate...

Страница 19: ...is displayed press the test button check mark to turn it on To turn the Link Light off press the test button until Linc OFF Continuous Loop Testing While in a cable test mode hold Test key for 2 seco...

Страница 20: ...ding a nominal 10 Volts peak to peak across the pair Figure 9 Tone Setup Menu Pressing the OK key toggles through cable types Data Video Phone Pressing the Test key toggles Tone on and off Pressing Up...

Страница 21: ...ded or Unshielded CAT7 CAT6A CAT5E CAT5 CAT4 CAT3 Coax Maximum Cable Length Testing 0 to 1 000 feet 305 meters Minimum Cable Length for Split Pair Detection 1 5 feet 0 5 meters Maximum Coax Cable Leng...

Страница 22: ...rks GmbH first obtain a Return Authorization number from our Customer Service by calling 49 89 45656660 The RMA must be clearly marked on the shipping label To Softing IT Networks GmbH Richard Reitzne...

Страница 23: ...23 NOTES...

Страница 24: ...RICA Germany Softing IT Networks GmbH Richard Reitzner Allee 6 85540 Haar Munich Phone 49 89 45 656 660 E mail info itnetworks softing com France Softing SARL Cr teil le de France Phone 33145172805 E...

Отзывы: