background image

ZK-S12-B User's Manual 

 

 

 

Page 6

 

Name Reference Description/Pinout

 

J106 
 

 

1

2

3

 

 

 

 

VRL SELECTION 

 

1-2 (GND) 

VRL tied to ground (default) 

2-3 (USER) 

VRL connected to the J104 
connector 

J107 
 

 

1

2

3

 

 

 

 

XFC SELECTION 

 

1-2 (LOOP FILTER) 
 

The on-board RC PLL loop filter 
is selected (default) 

2-3 (USER) 

The XFC PLL loop filter pin is 
connected to signal pin connector 

J109 
 

 

1

2

3

 

 

 

 

VOLTAGE REGULATOR ENABLE 

 

1-2 (1) 

Microcontroller internal voltage 
regulator enabled (default) 

2-3 (0) 

Microcontroller internal voltage 
regulator disabled. VDD1, VDD2 
and VDDPLL must be supplied 
externally. 

J110 

 

 

MODA=1 

 
Installed 

MODA line pulled to VDD 

Not Installed 

MODA line tied to ground by 
internal pull down (default) 

J111 

 

 

MODB=1 

 
Installed 

MODB line pulled to VDD 

Not Installed 

MODB line tied to ground by 
internal pull down (default) 

J113 
 

 

1

2

4

6

3

5

 

OSCILLATOR SELECTION 

 
1-2 (CLOCK)

 

Clock selected

 

3-4  (PIERCE) 

Pierce crystal configuration selected 

5-6 (COLPITTS) Colpitts crystal configuration 

selected (default) 

J114 
 

 

1

2

4

6

3

5

 

OSCILLATOR SELECTION 

 
1-2 (CLOCK)

 

Clock selected

 

3-4  (PIERCE) 

Pierce crystal configuration selected 

5-6 (COLPITTS) Colpitts crystal configuration 

selected (default)

 

J115 

 

 

XCLKS#=0 

 
Installed 

XCLKS# pin pushed to ground. Full-
swing Pierce crystal configuration or 
clock selected. 

Not Installed 

XCLKS# pulled to VDD. Loop 
controlled Colpitts crystal 
configuration selected. (default) 

J202 
 

 

1

2

3

 

 

 

 

VDD SELECTION 

 
1-2 (3V3) 

VDD = 3.3 V  

2-3 (5V) 

VDD = 5 V (default) 

J204 

 

1

 

 

 

LED ENABLE 

 

Installed 

The LEDs are connected to the 
PB[7..0] port of the 
microcontroller (default) 

Not Installed 

The LEDs are not connected to the 
microcontroller. 

Downloaded from 

Elcodis.com

 

electronic components distributor

 

Содержание ZK-S12-B

Страница 1: ...f Metrowerks Corp Metrowerks is a wholly owned subsidiary of Freescale Semiconductor Microsoft and Windows are trademarks or registered trademarks of Microsoft Corporation PC is a registered trademark...

Страница 2: ...he microcontroller through a standard USB interface USB 2 0 is fully supported When using an external in circuit debugger via the BDM connector the USB TO BDM INTERFACE circuitry must be bypassed by r...

Страница 3: ...to use the RS 232 LIN or to free the microcontroller s RX and TX lines associated with these nodes Two 3x1 male header connectors are provided to interface to an external LIN bus 10 The SERIAL SETTING...

Страница 4: ...s XCLKS 0 Jumper OSC SEL Jumpers XCLKS 0 Jumper OSC SEL Jumpers XCLKS 0 Jumper MC9S12A32 PIERCE Installed COLPITTS Not Installed CLOCK Installed MC9S12A64 PIERCE Installed COLPITTS Not Installed CLOCK...

Страница 5: ...Installed MC9S12KL64 PIERCE Installed CLOCK Installed MC9S12KL128 PIERCE Installed CLOCK Installed MC9S12XDT512 PIERCE Installed CLOCK Installed Peripherals Some devices do not feature the same number...

Страница 6: ...Installed MODB line tied to ground by internal pull down default J113 1 2 4 6 3 5 OSCILLATOR SELECTION 1 2 CLOCK Clock selected 3 4 PIERCE Pierce crystal configuration selected 5 6 COLPITTS Colpitts c...

Страница 7: ...onfigured as DTE J305 1 2 3 RS 232 1 DTE DCE SELECTION 1 2 DCE The RS 232 channel 1 is configured as DCE default 2 3 DTE The RS 232 channel 1 is configured as DTE J306 1 2 3 RS 232 1 DTE DCE SELECTION...

Страница 8: ...2 Microcontroller s PS0 RXD0 pin connected to RS 232 0 transceiver default 2 3 LIN Microcontroller s PS0 RXD0 pin connected to LIN0 transceiver J320 1 2 3 TXD0 SELECTION 1 2 RS 232 Microcontroller s P...

Страница 9: ...J108 Ground Test Point J112 1 BDM Connector 1 BKGD 2 GND 3 N C 4 RESET 5 N C 6 VDD J201 1 2 12 V DC Power Supply Input Connector 1 12 V DC 2 GND J203 Ground Test Point J301 6 9 5 1 RS 232 0 Connector...

Страница 10: ...GND J315 1 3 CAN0 Connector 1 CANH CAN Differential Bus Line 2 GND 3 CANL CAN Differential Bus Line J318 1 3 CAN4 Connector 1 CANH CAN Differential Bus Line 2 GND 3 CANL CAN Differential Bus Line J40...

Отзывы: