6.4.9 Test Sound Masking
The Test Sound Masking function is used to validate the equalization process in any zone and can
be used to adjust the emitted masking sound manually or automatically.
When the Test Sound Masking function is activated, the following interface is displayed
:
Figure 39: Test Calibration interface
This function is a spectrum analyzer that compares the measured sound (blue curve) with the
Target Masking Spectrum (green curve).
This button allows the measurement to be started or stopped. The
difference between the target spectrum and the measure is displayed in the
upper right hand corner.
The analyzer presents the standard Leq averaging, but the statistical level
of the noise measurement (L1%, L5%, L10%, etc.), which can be useful in
some measurement conditions, is also available. The user can export the
graph for further analysis and reports.
The "Set EQ Mode" button is used to switch between the Automatic
Equalization mode and the Manual Equalization mode. When you click on
this button, the Equalization Mode menu appears: