11.1.2 

13mm (f1.1) Manual Focus Lens Dimensions 

 

Содержание 1024-20C

Страница 1: ...Page 1 ATOMTM 1024 User Manual TM ATOM is a trademark of Sofradir EC Inc...

Страница 2: ...ribed in it are copyrighted with all rights reserved This manual and the software may not be copied in whole or in part except as pertains to the normal use of the product such as backup copies withou...

Страница 3: ...6 4 3 DIGITAL VIDEO OUTPUT INTERFACE 17 4 3 1 Camera Link interface C models 18 4 3 2 GigE interface G models 18 4 3 3 LVTTL interface L models 19 4 4 CAMERA MOUNT FOR C AND G MODELS 21 4 5 LENSES 21...

Страница 4: ...onfig 54 10 1 2 Safe Shutdown 54 10 2 INFO TAB 55 10 3 VIDEO TAB 56 10 3 1 Detector Disable 56 10 3 2 External Sync Edge Detection 56 10 3 3 Select Image Zoom 58 10 3 4 Zoom Window 58 10 3 5 Lens Sele...

Страница 5: ...11 6 ATOM 1024 G CZ 25 150MM MODEL INTERFACE PHYSICAL DIMENSIONS 75 11 7 ATOM 1024 G CZ 15 100MM MODEL INTERFACE PHYSICAL DIMENSIONS 76 12 SPECIFICATIONS 77 13 MAINTENANCE 78 13 1 CLEANING 78 13 1 1...

Страница 6: ...istribution media is subject to the terms of the end user license agreement You should not use the camera or any related software until you have read the end user license agreement The complete end us...

Страница 7: ...r not since this may cause damage to the detector or to its factory calibration Accessories Use only the approved accessories and options with this product Incompatible accessories may damage the came...

Страница 8: ...l focus OR 50mm f1 2 fixed focus 20 1024 20C Camera Link 1024 20G GigE 1024 40L LVTTL 25mm f1 2 fixed focus 40 1024 40C Camera Link 1024 40G GigE 1024 67 10G GigE 15 100mm f1 4 continuous zoom motoriz...

Страница 9: ...Supply PC running XP Vista Win7 with latest Service Packs installed and at least one of the following o 1000Base T Ethernet interface for cameras with GigE Video interface o Camera Link Frame Grabber...

Страница 10: ...anced Interface Guide Atom 1024 Software Development Kit 3 2 3 Frame Grabber support notes Some Camera Link frame grabbers require a minimum pixel clock of 20MHz The ATOM 1024 will need to be configur...

Страница 11: ...coupled with its superior thermal image quality makes for ideal integration within military and COTS thermal imaging systems and an excellent choice for handheld ground airborne EOIR platforms and adv...

Страница 12: ...is an example of an ATOM 1024 with a GigE video interface with an f 1 2 50mm fixed focus lens See Section 4 2 1 for the power supply pin layout See Section 4 3 2 for more on the GigE video interface...

Страница 13: ...ATOM 1024 with an LVTTL video interface with an f 1 0 50mm manual focus lens See Section 4 3 3 for the power supply pin layout See Section 4 3 3 for more on the LVTTL video interface The LVTTL model...

Страница 14: ...e 14 4 1 4 Continuous Zoom The Continuous Zoom models come with a GigE video interface See Section 4 2 3 for the power supply pin layout See Section 4 3 2 for more on the GigE video interface Power Gi...

Страница 15: ...rose p n HR10A 7R 5S 73 See Figure 1 for connector pin location and Table 1 Power input connector pin out for connector pin out Figure 1 Power input connector pin ID Table 1 Power input connector pin...

Страница 16: ...25mm The parts included to power the CZ camera with part numbers from TE Connectivity Power Supply 12V 1 5A minimum 2 pin housing 770602 2 Crimps 770601 2 Crimp Tool 58517 1 Negative Positive 422 Leve...

Страница 17: ...resolution of the output signal Digital zoom level Apply an image zoom transformation between the input and output images The following table identifies the video modes and provides explicit input an...

Страница 18: ...Link standard which supports 5 LVDS pairs for the serialized video data and sync 2 LVDS pairs for asynchronous serial communication and 4 LVDS pairs for discrete control signals The discrete control...

Страница 19: ...a framing clock and 2 asynchronous serial signals along with 2 control signals and power The connector is a 70 pin 0 5mm pitch board to board 2mm height header Hirose p n DF17 2 0 70DP 0 5V 57 See Tab...

Страница 20: ...CLOCK Clock used to synchronize the data FRAME_SYNC Frame Sync used to signal the start of a frame LINE_SYNC Line Sync used to signal the start of a line RS232_TX Serial Data received by the ATOM RS23...

Страница 21: ...amera Mount for C and G models The ATOM 1024 C and G models have a camera mount so the camera may be mounted on a tripod The L models do not have a camera mount 4 5 Lenses ATOM 1024 lenses come in thr...

Страница 22: ...Page 22 4 5 1 Manual Focus 13mm 50mm 4 5 1 1 13mm f 1 1 Manual Focus 73 FOV 4 5 1 2 50mm f 1 0 Manual Focus 20 FOV...

Страница 23: ...2 Rotate the inner lens to the appropriate new location 3 While holding the inner lens in place use the grooves to turn the lock ring clockwise until it locks tight Important Be careful to not overtur...

Страница 24: ...cled below 3 Hand tighten the screw Note Do not grip the Outer Lens to change focus as it will not adjust the focus it can turn independently of the focus grip Special to the Athermal Lens You will no...

Страница 25: ...Page 25 4 5 3 Continuous Zoom 4 5 3 1 25 150mm f 1 4 Continuous Zoom motorized focus 6 6 40 FOV 4 5 3 2 25 225mm f 1 5 Continuous zoom motorized focus 4 4 40 FOV...

Страница 26: ...Link Cable Mini Standard o 2m 915154 o 5m 915155 o 10m 915156 Power Supply with serial cable 915288 Camera Link Frame Grabber Boards o 16MB PCI 1426 16 915219 o 32MB PCI 1426 32 915220 o PCI 1428 9152...

Страница 27: ...erformance and reliability and provides no direct support for these products 5 1 1 Pleora PureGEV For information regarding Pleora release compatibility please reference the release notes The Pleora P...

Страница 28: ...n to continue to install the software Read the end user software license agreement and click the bullet next to the statement of accept once the license agreement has been reviewed and agreed to Click...

Страница 29: ...n the Next button to continue If the default folder location is not acceptable click on the Change button to edit the folder location then click on the Next button to continue Click on the Install but...

Страница 30: ...Page 30 Click on the Finish button when completed...

Страница 31: ...31 Following a successful installation these new items should appear on your Start menu under the Pleora Technologies Inc heading Select the item for GEVPlayer to start the video acquisition applicat...

Страница 32: ...r The recommended settings will present the ATOM GUI installation path by default A manual installation path can be selected by clicking browse and selecting a folder through the explorer Also at this...

Страница 33: ...t device driver for GigE camera models 1 Run the Driver Installation Tool from All Programs Pleora Technologies Inc eBUS SDK Tools 2 Verify the current driver installed 3 Select the driver from the Ac...

Страница 34: ...e camera 6 1 NI camera file icd 1 Locate the NI camera file icd on the CD DVD Release disk or electronic mail 2 Copy the NI camera file to Vision Acquisition Software prior to 8 2 3 Place the icd file...

Страница 35: ...e SEC provided camera files icd have been copied to the appropriate folder on your PC as described in the section above 2 Run the NI Camera File Generator program 3 On the initial screen click on the...

Страница 36: ...d it to the list 5 If other firewall software is installed e g Norton Internet Security use the equivalent procedure to permit access 7 2 Configure the GigE for point to point connection for GigE came...

Страница 37: ...t mask Note The Subnet mask may automatically be filled in with 255 255 255 0 after the IP address is entered 6 Click Ok when done 7 2 2 Restore NIC setup for network connection DHCP delivered IP addr...

Страница 38: ...ames packets For Windows 7 1 Select Start 2 Right click on Computer 3 Select Manage 4 Click on Device Manager on the left side 5 Click on Network Adapters in the center 6 Right click on the Network Ad...

Страница 39: ...multicast mode must be used for streaming Without multicast enabled video can be displayed but the camera controls are unavailable Important Note Multicast mode uses IGMP and requires an IGMP complia...

Страница 40: ...GEV Player main screen Select Tools then Setup 8 From the Setup window select Data receiver and Multicast 9 Make sure that the Multicast address from the GEV Player matches the Atom Gui Multicast Addr...

Страница 41: ...which to connect to an image acquisition device b For Camera Link connect the Mini Camera Link connector to the Frame Grabber with a Camera Link cable c For GigE connect the GigE Video RJ 45 connector...

Страница 42: ...se right click on the Channel item and select Open Camera This will allow you to browse to your Installation CD s camera file 6 Navigate to your CD drive containing the Atom1024 installation disk Navi...

Страница 43: ...yer to acquire images Acquire video by performing the steps for a network connection or point to point connection Note There is a workaround needed to be performed in order to simultaneously use the G...

Страница 44: ...mages is incrementing 8 2 2 2 GigE Video interface point to point connection 1 Configure the PC s NIC for a static IP address Section 7 2 1 2 Launch GEVPlayer from the desktop shortcut or the start me...

Страница 45: ...Page 45 5 Select the Gig E interface...

Страница 46: ...Page 46 6 Select the Set IP Address button...

Страница 47: ...Page 47 7 Enter a two as the last digit of the IP address and click OK...

Страница 48: ...Page 48 8 Verify the IP Configuration is Valid now...

Страница 49: ...9 9 Select the GigE interface and click OK 10 The following warning may be displayed Click Ok Note It is recommended to go back and update the Ethernet device driver for improved performance See Secti...

Страница 50: ...am number of images is incrementing 8 2 3 LVTTL interface Note The LVTTL interface is intended to connect to custom designed hardware The custom designed hardware will provide an interface from which...

Страница 51: ...left at a speed that depends on the configured image size Follow the instructions in Section 8 2 2 that describes configuring GEV Player in Unicast mode to resolve this problem Note that the camera ma...

Страница 52: ...ismatch between the display window size and the screen resolution If you see this effect try resizing the window until the displayed image is clean In this example a dramatic improvement to the image...

Страница 53: ...e workaround is in Section 7 4 9 2 AtomGui application overview The AtomGui sample application provides a user interface to control the camera The GUI handles proper command formation and communicatio...

Страница 54: ...of Camera Link frame grabbers installed in the PC or if the frame grabber supports dual Base configuration the Serial Port selection may be CAMERALINK0 or CAMERALINK1 There may be multiple cameras co...

Страница 55: ...pressing the Refresh button Initiate a self test operation by pressing the Self Test button This operation can take several minutes during which the Image ready box will not be checked when you refres...

Страница 56: ...nal clock and secondarily to align the start of frame integration activity with external events Full camera performance is achieved at rates approximately equal to the 30Hz frame rate used to calibrat...

Страница 57: ...ination of successful operation is left to the user Figure 2a External Sync Edge Triggering Timing Diagram with Zoom disabled Table 7 External Sync Timing Parameters Symbol Parameter Min Max units X T...

Страница 58: ...performed at reduced Frame Rate this operation takes proportionally longer to complete and may look like a non responsive system at really low e g 0 5HZ external clock rates In applications that requ...

Страница 59: ...the bullet next to 8 bits per pixel or 14 bits per pixel The camera will default to be 8 bits per pixel Note When operating in 8 bit mode the output bits will occupy the most significant bit positions...

Страница 60: ...ix Test Patterns you may choose from All White All Black Col Ramp Black White Col Ramp White Black Row Ramp Black White and Row Ramp White Black Note The test patterns are labeled as they appear for a...

Страница 61: ...st with visible cameras Level Mode The level mode defaults to Automatic Level Manual Level The Level setting allows manual gain level control of the digital outputs similar to image brightness with vi...

Страница 62: ...f the box Click Resize then click and drag the frame box to align the bottom right corner with the live image Once your box is set click Crop to select the area you would like AGC to be applied to To...

Страница 63: ...which if the ambient temperature of the current plateau has changed by more than this percentage a Touchup is automatically performed By default the shutter mode is set to Automatic By default the Me...

Страница 64: ...nd Focus may be adjusted different ways Clicking the Wide Mid or Narrow or Far Close buttons Using the up down Coarse and Fine buttons Clicking along the zoom or focus bar Clicking and dragging the cu...

Страница 65: ...abled unchecked Zoom 1X Output Bits 8 bits per pixel Frame Rate Normal Output NUC and BP Correction Corrected Video Source Detector Test Pattern Selection All White Edge Detection Falling Edge Image P...

Страница 66: ...e 66 11 Physical Dimensions Drawings This section contains the physical dimension drawings for each permutation of the ATOM 1024 camera 11 1 Standard lens Dimensions 11 1 1 Universal Lens Mount Intefa...

Страница 67: ...Page 67 11 1 2 13mm f1 1 Manual Focus Lens Dimensions...

Страница 68: ...Page 68 11 1 3 25mm f1 2 Athermal Fixed Focus Lens Dimensions...

Страница 69: ...Page 69 11 1 4 50mm f1 2 Athermal Fixed Focus Lens Dimensions...

Страница 70: ...Page 70 11 1 5 50mm f1 0 Manual Focus Lens Dimensions...

Страница 71: ...Page 71 11 2 ATOM 1024 20 C Model Physical Dimensions Note Drawing displays the model without a lens mounted...

Страница 72: ...Page 72 11 3 ATOM 1024 G Model Interface Physical Dimensions Note Drawing displays the model without a lens mounted...

Страница 73: ...Page 73 11 4 ATOM 1024 L Model Interface Physical Dimensions Note Drawing displays the model without a lens mounted...

Страница 74: ...Page 74 11 5 ATOM 1024 G CZ 25 225mm Model Interface Physical Dimensions...

Страница 75: ...Page 75 11 6 ATOM 1024 G CZ 25 150mm Model Interface Physical Dimensions...

Страница 76: ...Page 76 11 7 ATOM 1024 G CZ 15 100mm Model Interface Physical Dimensions...

Страница 77: ...a Link option 61 x 69 x 66mm 2 4 x 2 7 x 2 6 Weight w o lens LVTTL option 250g Weight w o lens Camera Link option 390g Weight w o lens Gigabit Ethernet option 500g Input Voltage 6 12 VDC Power Consump...

Страница 78: ...plastics will dissolve in alcohol or acetone 13 2 Replacing Components There are no user serviceable parts inside the camera For service please contact Sofradir EC 14 Warranty 1 Seller warrants that...

Страница 79: ...r 7 Caveat Emptor The Warranty contained herein is exclusive and expressly in lieu of all other warranties written oral implied or statutory including but not limited to express or implied warranties...

Страница 80: ...You are required to provide the following information Model and serial number of camera Your shipping address Your billing address if different Your fax telephone numbers and or email address Descript...