SOEKS soeks-01m Скачать руководство пользователя страница 1

Содержание soeks-01m

Страница 1: ......

Страница 2: ...on 26 Precautions 27 Appearance of the Device 28 Controls 28 Power 29 Screen Indicators 30 Main menu 35 Units 35 Language 36 Settings 36 Level in mcR h 36 Level in mcSv h 36 Vision 37 Sound 37 Power 38 Power control of the device 39 Beginning to Use the Device 40 ...

Страница 3: ...on radiation gamma radiation and beta particles stream with taking into account x ray radiation Base kit Ecotester SOEKS has the following items included in the base kit Ecotester Soeks 1 pcs Passport 1 pcs 2 batteries AAA size 2 pcs Rigid paperboard box 1 pcs Battery charger power cord rechargeable batteries and other accessories and supplies are purchased separately A Geiger Muller counter is us...

Страница 4: ...er voltage range V 1 9 3 5 Time of continuous work 10 of the device hours at least Overall dimensions 144х47х17 height х width х thickness max mm Weight without power 66 elements max grams Battery charging current max mA 300 Current consumption from charger 500 or USB not more than Output charger voltage from 4 5 to 5 5 Display Color TFT 128x160 Operating temperature range С from 20 to 60 Comment ...

Страница 5: ...places with intensive sun light or high tempera tures for a long time this can cause electrolyte leakage from power elements failure of the product and injuries Do not leave the product for a long time near devices that generate strong magnetic fields such as magnets or electric motors and where strong electrical magnetic signals are generated such as transmitter towers Do not perform measurements...

Страница 6: ...ation in nitrat tester mode Button ENTER confirm selection Button BACK back to previous menu Button UP moving up in the menu Button DOWN moving up in the menu Button BACK Protective cap Measuring probe Color TFT display Button OK Button DOWN mini USB Button ENTER Button UP 28 ...

Страница 7: ...ins If connected to a PC or electric mains the device can work without power elements How to install power elements Strictly observe polarity when you install power elements otherwise the device may fail The type of power elements installed must match the parameters preset in the Power menu item page 38 When the device is turned off you can leave the power elements installed the batteries and accu...

Страница 8: ...tivity during the previous minute The diagram keeps moving from right to left and the bar height shows the level of background radiation the higher the background the taller the bar The bar may be blue yellow and red 3 USB indicator USB cable connected batteries are charging charging completed 4 Battery charge status indicator normal power level running down low power level replace or recharge the...

Страница 9: ...ed the ENTER button was pressed the DOWN button was pressed the OK button was pressed Menu indication and navigation 6 The current selected line is highlighted with color 7 Inside a selected menu item the upper line on the list indicates the parent menu item 8 As the device is being set up the current parameter value is flagged with a tick mark Level mcR h 30 Settings Level mcSv h 0 3 Vision Sound...

Страница 10: ... 12 Radiation level Shown as large digits in the screen center The first measurement also shows the word MEASURING 13 The message about radiation bagkground if the measured background radiation is less than 40 mcR h a NORMAL RADIATION BACKGROUND indication appears on a green background if measured background radiation is 40 120 mcR h caption HIGH RADIATION BACKGROUND appears on a yellow background...

Страница 11: ...f sharp changes of radiation background with reflection of exact data takes no more than 10 20 seconds 15 The indicator of defining radiation fractions If the fractions follow often than the indicator blinks with yellow and red if the fractions are rare the indicator is yellow 16 The indicators of radiation background changes One red up arrow appears when increasing of radiation background is more...

Страница 12: ...ult of nitrate concentration exceeds the medium norm of nitrate consumption not more than 20 you will see the following message marked yellow Insignificant excess of standart if the measured result of nitrate concentration exceeds the medium norm of nitrate consumption not more than 50 you will see the following message marked red Significant excess of standart if the measured result of nitrate co...

Страница 13: ... a millisievert 1 mSv is one thousandth of one Sievert Millisievert is often used as a measure unit in diagnostic procedures X raying X ray computed tomography etc Microsievert 1 mcSv is one thousandth part of a millisievert or one millionth part of one Sievert Film photofluorography equals 500 800 mcSv digital is 60 mcSv Computed skull tomography on a step by step tomograph ensures 1 000 15 000 m...

Страница 14: ...R Then select the language you need Settings In this section you can preset the parameters for the device and the interface Items of the Settings menu Level in mсR h Level in mcSv h These items are related when one is changed the other also changes You can select the threshold value from 16 preset values on the list mcR h mcSv h 30 0 3 40 0 4 50 0 5 60 0 6 70 0 7 80 0 8 90 0 9 100 1 120 1 2 150 1 ...

Страница 15: ... yes cancels the MinutesOn parameter Backlight is always on while the device is in use no the screen s backlight works as preset in the MinutesOn function Theme Select from 4 possible combinations of background and font color green gray blue and white Sound In this item you can adjust the sound parameters Sound on yes no Sound tone Select one of the 4 available sound tones Keypad tone yes no To sa...

Страница 16: ...mulators will recharge while connected to a PC or charger via a mini USB slot Attention Never connect the device to a charger or a PC if it has batteries installed This can overheat the power elements cause their failure and electrolyte leakage damage the case and break the device Sleep Set the time in minutes after which the device shall automatically shut down AlwaysOn yes cancels the value of t...

Страница 17: ...l the display shows an animated screen with falling autumn leaves Then release the MENU button Pressing and holding the OK button will turn the device off in any mode 3 While connected to a USB the device will be on even without power elements installed If the device automatically turned on while connected to USB disconnecting the device from the USB slot will shut down the device When the device ...

Страница 18: ...asuring radiation background of objects To measure radiation background of foodstuffs building materi als and other things do this sequence 1 Measure the level of radiation background several meters away from the target 2 Move the device directly to the target and measure radiation background as close as possible to the target 3 Compare the resulting data with the radiation background level measur...

Страница 19: ...t 60 Apricot Banana 200 Banana Beet 1400 Beet Cabbage early 900 Cabbage E Cabbage late 500 Cabbage L Carrot early 400 Carrot E Carrot late 250 Carrot L Cucumber soil 150 Cucumber S Cucumber gr 400 Cucumber G Eggplant 300 Eggplant Grapes 60 Grapes Greengrocery 2000 Greengrocery Pear 60 Pear Lettuce 2000 Lettuce Marrow 400 Marrow Melon 90 Melon Nectarine 60 Nectarine Onion Bulb 80 Onion Bulb Onin Gr...

Страница 20: ...ill be shown 7 Stick the probe info the tested foodstuff hold the device perpendicularly to it in direction to the center of it Do not move or the press probe The depth of sticking the probe should be at least 10 mm The pointed cone of the probe should not go out of the foodstuff be in the seed zone or hollow spaces It should be sticked to the most juicy part of the foodstaff Notice that you shoul...

Страница 21: ...abbage lettuce have high norm of nitrates Normal concen tration for beet is 1400 mg kg If you eat such foodstuffs in large amounts please keep in mind maximum harmless doses that were pointed earlier Example You measured beet and nitrat tester measured 1000 mg kg nitrates per kilo This concentration is normal for this foodstuff and you can eat not more than 200 grams of such beet Notice that there...

Страница 22: ...х либо заметных изменений в тканях и органах 0 75 Зв незначительные изменения в крови 1Зв нижний предел начала лучевой болезни 3 5 Зв тяжёлая степень лучевой болезни погибают 50 облучённых To conclude description here are values of maximum permissible doses and certain official information about consequences of radiation exposure for humans 20 mSv maximum permissible dose MPD annual highest value ...

Страница 23: ...осительная влажность при температуре 25 С не более 90 Изделие до введения в эксплуатацию следует хранить на складе в упаковке предприятия изготовителя при температуре окружающей среды от 5 до 40 С и относительной влажности воздуха не более 80 при температуре 25 C Хранение изделия без упаковки не допускается Изделие в течение длительного времени находящееся при температуре ниже 0 С должно быть выде...

Страница 24: ...ures from 40 to 60 C relative humidity max 90 at 25 C Until operation the device must be stored in the factory package in a warehouse with air temperatures from 5 to 40 C and maximum relative air humidity 80 at temperature 25 C The device may not be stored without the package If the device remained at below zero tempera tures for a long time it must be left indoors for 2 hours before use Maintenan...

Страница 25: ...__________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ Исполнитель By________________________________________ _______________________________________________________ Владелец Owner________________________________________ _______________________________...

Страница 26: ......

Отзывы: