socorex ACURA 815 Скачать руководство пользователя страница 9

1

PERFORMANCE AND 

TECHNISCHE DATEN UND 

DONNÉES TECHNIQUES ET

ORDERING INFORMATION 

BESTELLINFORMATIONEN 

CATALOGUE 

Acura 815, fixed volume micropipettes

Volume 

µL

Inaccuracy 

(E%)

Imprecision 

(CV%)

Socorex 

Cat. No.

Tip 

style

1

<+/- 2.0 %

< 1.0 %

815.0001

Ultra

10 µL

5

<+/- 1.4 %

< 1.0 %

815.0005

Ultra

10 µL

10

<+/- 0.7 %

< 0.7 %

815.0010

Ultra

10 µL

10Y

<+/- 0.7 %

< 0.8 %

815.0010Y 200 µL

15

<+/- 0.7 %

< 0.5 %

815.0015

200 µL

20

<+/- 0.75 %

< 0.5 %

815.0020

200 µL

25

<+/- 0.7 %

< 0.6 %

815.0025

200 µL

30

<+/- 0.7 %

< 0.6 %

815.0030

200 µL

32

<+/- 0.7 %

< 0.6 %

815.0032

200 µL

40

<+/- 0.7 %

< 0.5 %

815.0040

200 µL

50

<+/- 0.7 %

< 0.4 %

815.0050

200 µL

60

<+/- 0.7 %

< 0.5 %

815.0060

200 µL

77

<+/- 0.7 %

< 0.4 %

815.0070

200 µL

75

<+/- 0.7 %

< 0.4 %

815.0075

200 µL

80

<+/- 0.7 %

< 0.35 %

815.0080

200 µL

90

<+/- 0.7 %

< 0.3 %

815.0090

200 µL

100

<+/- 0.7 %

< 0.3 %

815.0100

200 µL

120

<+/- 0.7 %

< 0.4 %

815.0120

200 µL

150

<+/- 0.7 %

< 0.3 %

815.0150

200 µL

200

<+/- 0.7 %

< 0.3 %

815.0200

200 µL

250

<+/- 0.7 %

< 0.4 %

815.0250

1000 µL

300

<+/- 0.7 %

< 0.4 %

815.0300

1000 µL

400

<+/- 0.7 %

< 0.3 %

815.0400

1000 µL

500

<+/- 0.7 %

< 0.3 %

815.0500

1000 µL

600

<+/- 0.7 %

< 0.3 %

815.0600

1000 µL

700

<+/- 0.7 %

< 0.2 %

815.0700

1000 µL

750

<+/- 0.7 %

< 0.2 %

815.0750

1000 µL

800

<+/- 0.7 %

< 0.2 %

815.0800

1000 µL

900

<+/- 0.7 %

< 0.2 %

815.0900

1000 µL

1000

<+/- 0.6 %

< 0.2 %

815.1000

1000 µL

Acura 835, fixed volume macropipettes

Volume 

µL

Inaccuracy 

(E%)

Imprecision 

(CV%)

Socorex 

Cat. No.

Tip 

style

2

<+/- 0.8 %

< 0.5 %

835.F02

2 mL

1)

2.5

<+/- 0.8 %

< 0.5 %

835.F02.5

5 mL

5

<+/- 0.7 %

< 0.3 %

835.F05

5 mL

10

<+/- 0.5 %

< 0.2 %

835.F10

10 mL

1)

 5 mL tip up to serial number 17091050

Smarties

 plunger caps

Colour

Socorex

Cat. No.

Colour

Socorex

Cat. No.

Smartie plunger caps, alternative colour selection  (6 / pack)
White

825.710

Rose

825.719

Grey

825.715

Pink

825.720

Vanilla

825.716

Purple

825.721

Lemon

825.712

Ice Blue

825.722

Yellow

825.717

Blue

825.713

Orange

825.718

Mint

825.723

Red

825.714

Green

825.711

Smartie mix assorted colours (14 / pack)

1.825.700

Acura 825, adjustable volume micropipettes

Volume

µL

Division

µL

Inaccuracy (E%)

Imprecision (CV%)

Tip style

Cat. No.

Min. vol. Mid. vol. Max. vol. Min. vol. Mid. vol. Max. vol.

0.1 – 2

0.002

<± 6.0 %

1)

<± 4.0 %

<± 2.0  %

< 5.0  %

1)

< 3.3  %

< 1.5  %

Ultra 10 µl

825.0002

0.5 – 10

0.01

<± 2.5 %

2)

<± 1.8 %

<± 1.0  %

< 1.8  %

1)

< 1.2  %

< 0.5  %

Ultra 10 µl

825.0010

1 – 10

0.01

<± 2.5 %

<± 1.8 %

<± 1.0 %

< 2.5  %

< 1.6  %

< 0.7  %

200 µl

825.0010Y

2 – 20

0.02

<± 2.5 %

<± 1.8  %

<± 1.0  %

< 1.7  %

< 1.1  %

< 0.5  %

200 µl

825.0020

5 – 50

0.1

<± 1.5 %

<± 1.3  %

<± 1.0  %

< 1.0 %

< 0.7  %

< 0.4  %

200 µl

825.0050

10 – 100

0.1

<± 1.5 %

<± 1.2  %

<± 0.8  %

< 1.0  %

< 0.6  %

< 0.2  %

200 µl

825.0100

20 – 200

0.2

<± 1.5 %

<± 1.1  %

<± 0.6  %

< 0.6  %

< 0.4 %

< 0.2  %

200 µl

825.0200

100 – 1000 1.0

<± 1.5 %

<± 1.0  %

<± 0.5  %

< 0.5  %

< 0.4  %

< 0.2  %

1000 µl

825.1000

1)

 Measured at 0.5 µL. Indicative data at 0.2 µL: E<± 12%, CV<8%.    

2)

 Measured at 1 µL. Indicative data at 0.5 µL: E <+5%, CV<3%.

Acura 835, adjustable volume macropipettes

Volume

mL

Division

mL

Inaccuracy (E%)

Imprecision (CV%)

Tip style

Cat. No.

Min. vol. Mid. vol. Max. vol. Min. vol. Mid. vol. Max. vol.

0.2 – 2

0.002

<± 1.5 %

<± 1.0 %

<± 0.5  %

< 0.5  %

< 0.3  %

< 0.2  %

2 mL

835.02

0.2 – 2

1)

0.002

<± 1.5 %

<± 1.0 %

<± 0.5  %

< 0.5  %

< 0.3  %

< 0.2  %

2 mL/Pasteur

835.02PP

0.5 – 5

0.01

<± 1.5 %

<± 1.1 %

<± 0.6 %

< 0.6  %

< 0.5  %

< 0.3  %

5 mL

835.05

0.5 – 5

1)

0.01

<± 1.5 %

<± 1.1  %

<± 0.6  %

< 0.6  %

< 0.5  %

< 0.3  %

5 mL/Pasteur

835.05PP

1 – 10

0.01

<± 1.5 %

<± 0.7  %

<± 0.5  %

< 0.5 %

< 0.3  %

< 0.2  %

10 mL

835.10

Measurements done with nozzle protection filter. Above values obtained using PP tips.

1)

 Model includes Pasteur adapter nozzle.

Acura 855, adjustable volume multichannel pipettes

Volume

µL

Division

µL

Inaccuracy (E%)

Imprecision (CV%)

Tip style

Cat. No.

Min. vol. Mid. vol. Max. vol. Min. vol. Mid. vol. Max. vol.

8-channel

0.5 – 10

0.01

<± 3.5 %

1)

<± 2.5 %

<± 1.5  %

< 3.0  %

1)

< 3.3 %

< 1.0  %

Ultra 10 µL 855.08.010

5 – 50

0.1

<± 1.0 %

<± 0.9 %

<± 0.8  %

< 1.0  %

< 1.3  %

< 0.4  %

200 µL

855.08.050

10 - 100

0.1

<± 1.0 %

<± 0.9 %

<± 0.8  %

< 0.9 %

< 0.6  %

< 0.4  %

200 µL

855.08.100

20-200

0.2

<± 0.9 %

<± 0.8 %

<± 0.7 %

< 0.6  %

< 1.6  %

< 0.3  %

200 µL

855.08.200

40 – 350

0.4

<± 1.0 %

<± 0.9  %

<± 0.8  %

< 0.6  %

< 1.1  %

< 0.3  %

350 µL

855.08.350

12-channel

0.5 – 10

0.01

<± 3.5 %

1)

<± 2.5 %

<± 1.5  %

< 3.0  %

1)

< 3.3  %

< 1.0  %

Ultra 10 µL 855.12.010

5 – 50

0.1

<± 1.0 %

<± 0.9 %

<± 0.8  %

< 1.0  %

< 1.3  %

< 0.4  %

200 µL

855.12.050

20-200

0.2

<± 0.9 %

<± 0.8 %

<± 0.7 %

< 0.6  %

< 1.6  %

< 0.3  %

200 µL

855.12.200

40 – 350

0.4

<± 1.0 %

<± 0.9  %

<± 0.8  %

< 0.6  %

< 1.1  %

< 0.3  %

350 µL

855.12.350

1)

 Measured at 1 µL. Performance values obtained with bi-dest. water at constant temperature (± 0.5°C) comprised between 

20 and 25°C in accordance with ISO 8655.

ACCESSORIES  ZUBEHÖR ACCESSOIRES

Description

Packaging

7 positions

Model 337

6 positions

Model 336

Universal work station – fits single channel pipettes of most brands

Grey

1 / pack

320.337G

320.336Q

Blue

1 / pack

320.337B

320.336B

Yellow

1 / pack

320.337Y

320.336Y

Green

1 / pack

320.337M

320.336G

Pink / Red

1 / pack

320.337R

320.336R

Orange

1 / pack

320.336O

White

1 / pack

320.336W

Description

Packaging

Socorex

Cat. No.

Work station 340 for 3 multi- or single-channel pipettes

1 / pack

320.340

Shelf pipette holder for 2 instruments (transparent blue)

1 / pack

320.332

4 / pack

320.332.4

V-shape, 70 ml, autoclavable PP reservoir

20 / pack

330.01

Large capacity with lid, 125 mL, autoclavable PP reservoir

20 / pack

330.01L

8-channel, 48 mL, sterile, single wrapped PS reservoir

10 / pack

330.08.9

12-channel, 48 ml, sterile, single wrapped PS reservoir

10 / pack

330.12.9

Nozzle protection filters, PP fibres, for 2 and 5mL models

250 / pack

322.05

Nozzle protection filters, PP fibres, for 10mL model

100 / pack

322.10

Pasteur pipette adapter, 2 mL model

1 / pack

1.835.631

Pasteur pipette adapter, 5 mL model

1 / pack

1.835.633

Protective calibration seal stickers

25 / bag

1.835.025

100 / bag

1.835.100

Содержание ACURA 815

Страница 1: ...C komplett zusammengesetzt autoklavierbar Hauptvorteile sind das Digital Display E f r eine per manente Volumenanzeige und das innovative JustipTM System H mit einem weich gepolsterten Abwurfknopf C f...

Страница 2: ...oder 1 835 633 5 ml erlau bend den Gebrauch von Pasteurpipetten bis zu 2 ml usserer 6 5 7 2 mm auf Anfrage erh ltlich Die auf Kontrollzertifikat angegebenen Daten wurden mit PP Spitzen erhalten bei B...

Страница 3: ...press plunger button in full Phase 2 Immerse tips vertically 2 3 mm into liq uid wait 2 sec and smoothly release plunger button Withdraw tips from liquid without touching container wall Phase 3 Place...

Страница 4: ...dem Zusammensetzen der Pipette O Ring leicht einfetten siehe unten Zerlegen der Volumeneinheit und Auswechseln des O Rings Modelle 815 825 835 2 ml Fig 6 Volumeneinheit Unterteil abnehmen 1 Abwurfkno...

Страница 5: ...r rod 11 and release ejector button Press firmly plunger button until plunger rod 28 clips in Control proper functioning of plunger and ejector buttons Set ejector height to desired position Fig 9 Fig...

Страница 6: ...bis mit tleres gemesse nes Volumen auf dem Digital Display er scheint ohne Druckknopf zu halten Kalibrationsschieber wieder in P osition lock bringen und Smartie K ppchen auf den Druckknopf setzen Nac...

Страница 7: ...Fig 12 und 13 Smartie kappe a vom Druckknopf entfernen und Kalibrationsschraube b entnehmen Kalibrations Siegeletikette c abziehen und Kalibra tionsschieber d mittels einer Pipettenspitze oder eines s...

Страница 8: ...6 Counter assembly adjustable 7 Dosing assembly fix 8 Handpiece 9 Window 10 Handpiece screw 2x 11 Ejector rod 12 Circlip 13 Plunger 14 Ring 15 Spring 16 PTFE sleeve 17 O ring plunger 18 Barrel 19 Ejec...

Страница 9: ...5 CV 3 Acura 835 adjustable volume macropipettes Volume mL Division mL Inaccuracy E Imprecision CV Tip style Cat No Min vol Mid vol Max vol Min vol Mid vol Max vol 0 2 2 0 002 1 5 1 0 0 5 0 5 0 3 0 2...

Страница 10: ...ue tip 1000 8 x 60 rack 318 1000R 4 x 250 bag 318 1000B Natural tip 1000 8 x 60 rack 309 1000R 4 x 250 bag 309 1000B Blue tip 1000 8 x 60 rack 319 1000R 4 x 250 bag 319 1000B Natural macrotip 2 mL 2 x...

Отзывы: