26
SUNSYS H50
- Ref.: IOMSUNHMXX05-GB 01
26
11. TECHNICAL SPECIFICATIONS
Model
SUNSYS H50
Enclosure
Powder coated aluminum
Operating temperature
-20 to +60 °C, full power up to 40 °C
Relative humidity
0 to 95% non-condensing
Cooling
Natural cooling
Protection level
IP65
Galvanic insulation
NO
Safety class
Class I metal casing with protective earth connection
Overvoltage category
III
Weight
24 kg
Dimensions
482 × 470 × 167 mm
Connectors
Weather resistant connectors
AC output (grid side)
Rated power
5000 VA
Maximum power
5000 VA
Voltage 230
Vac
Rated current
21.7 A
Max current
24.5 A
Frequency 50
Hz
Total Harmonic Distortion
< 3% at rated power*
Power factor
> 0.99 at rated power*
Night time power
< 2 W
Maximum efficiency
> 97.50%
European efficiency
> 97.00%
AC connector
IP67 single-phase + N PE
Recommended protection
Thermal-magnetic with I = 1.25 x Inom
DC input (solar side)
Maximum input power
5600 Wp
Rated voltage
650 Vdc
Operating voltage
200 to1000 Vdc
Start-up voltage
> 250 Vdc
Absolute maximum voltage
1000 Vdc
MPP voltage range
at rated power
310 to 850 Vdc
Number of inputs
2 (1 MPPT)
MPPT
1
Rated current
17.5 A
System information / communication
User interface
LCD alphanumeric display, (16 x 2 caracters)
Data logger with 10 year capacity
and real time clock
30 events
External communication
RS-485 connection