socomec NETYS PR 1000 Rack 1U Скачать руководство пользователя страница 2

2

NETYS PR RACK 1U

 - Ref.: IOMNETPRXX01-GB  02

This SOCOMEC UPS appliance is guaranteed against manufacturing and material defects for a period of 12 months from the 
date of purchase (local warranty conditions are applicable in addition to the general conditions). This warranty certificate should 
NOT be e-mailed, but kept by the customer along with proof of purchase, for use in the event of a claim being made for repairs or 
replacement under warranty.

The warranty period commences on the date the new product was purchased by the end user at an authorised showroom (reference 
details are shown on the receipt). 

Return-to-base warranty is provided: components and labour for repairs supplied free of charge, any products to be replaced must 
be returned to SOCOMEC UPS or authorised service centres, at the customer’s own risk and expense.

The warranty is recognized within national territory. If the UPS is exported out of national territory, the warranty shall be limited to the 
cover of the parts used to repair the fault.

To claim service under the warranty please observe the following:

  

The product must be returned in the original packing. Any damage caused during shipping in packaging other than the original 
will not be covered by the warranty;

  

The product must be accompanied by proof of purchase such as an invoice or receipt indicating the date of purchase and 
product ID information (model, serial numer). The sender must also attach the reference number issued to authorise the return 
of the product, together with a detailed description of the defect. If any of this information is missing the warranty will be invalid. 
The authorisation number is issued by service centres over the telephone on receiving information on the malfunction in question;

  

If it is not possible to provide proof of purchase the serial number and date of manufacture will be used to calculate the probable 
expiry date of the warranty; this could result in a reduction of the original warranty period.

The warranty on the product does not cover damage caused by carelessness (improper use: wrong input power, explosions, 
excessive humidity, temperature, poor ventilation, etc.), tampering or any unauthorised repair work.

During the warranty period, SOCOMEC UPS reserves the right to decide whether the product should be repaired, or whether to 
replace defective parts with new parts, or used parts that are equivalent to new parts in terms of functionality and performance. 

In the case of batteries, warranty is valid only if the battery has been recharged regularly in accordance with the manufacturer’s 
instructions. On purchasing the product it is advisable to check that the next recharge date indicated on the packaging has not expired.

Battery

• Batteries are treated as consumable parts and warranty only covers manufacturing defects.

• Batteries must be stored in compliance with Supplier recommendations.

•  Warranty is valid only if the battery has been recharged regularly in accordance with the manufacturer’s instructions. On purchasing 

the product it is advisable to check that the next recharge date indicated on the packaging has not expired.

Optionals

A 12-month return-to-base warranty is provided on optionals.

Software products

Software products are guaranteed for 90 days. The software is guaranteed to work as indicated in the manual accompanying 
the product. Hardware media or accessories (e.g. diskettes, cables, etc.) used with appliances are guaranteed free of material or 
manufacturing defects under normal conditions of use for a period of 12 months from the date of purchase.

SOCOMEC UPS will not be responsible for damages (including loss of income, interruption of business activity, loss of information 
or other financial losses, of any nature) arising from the use of the product.

These conditions are subject to Italian law. Disputes shall come under the jurisdiction of Court of Vicenza.

WARRANTY CERTIFICATE AND CONDITIONS

SOCOMEC UPS retains the full and exclusive ownership rights over this document. Only a personal right to utilize the document 
for the application indicated by SOCOMEC UPS is granted to the recipient of such document. All reproduction, modification, disse-
mination of this document whether in part or whole and by any manner are expressly prohibited except upon Socomec’s express 
prior written consent.

This document is not a specification. SOCOMEC UPS reserves the right to make any changes to data without prior notice.

Содержание NETYS PR 1000 Rack 1U

Страница 1: ...stallation et d utilisation FR Installation and operating manual GB Manuale di installazione e uso IT MK Installatie en bedieningshandleiding NL Dokumentacja Techniczno Ruchowa PL Manual de instala o...

Страница 2: ...y temperature poor ventilation etc tampering or any unauthorised repair work During the warranty period SOCOMEC UPS reserves the right to decide whether the product should be repaired or whether to re...

Страница 3: ...ECTION 11 7 MODES OF OPERATION 12 7 1 TURNING THE UPS ON 12 7 2 TURNING THE UPS OFF 12 7 3 STANDBY MODE 12 7 4 INITIATING THE SELF TEST 12 8 ADDITIONAL UPS FEATURES 13 8 1 VOLTAGE CONFIGURATION 13 8 2...

Страница 4: ...ose of batteries in a fire the battery may explode CAUTION A battery can present a risk of electric shock and high short circuit current The following precaution should be observed when working on bat...

Страница 5: ...ower supply which duly filtered and stabilised on models with AVR and if considered suitable is used to supply consumers In cases of a mains failure or if the mains is considered to be outside limits...

Страница 6: ...9 Rack 3 1 2 Adjusting the Rail Depth 3 1 3 Securing the Rear Rail 3 1 4 Securing the Front Rail Mounting Bracket M3x6 Bracket Screws Rear Hold Down Bracket Rear Front Assembly Wing Nuts Assembly Wing...

Страница 7: ...LLATION 3 1 5 Securing the UPS in a 19 Rack 3 1 6 Rack Tray and Mounting Bracket for a 23 Cabinet 3 1 7 Securing the UPS in a 23 Rack Mounting Bracket M3x6 Bracket Screws Rack Tray NOTE Rails cannot b...

Страница 8: ...GB 02 3 INSTALLATION 3 1 8 Zero U Mounting 3 1 9 Mounting the UPS to a Wall Side of Rack Cabinet within 22 54 22 78 or 56 35 56 95 cm WARNING The UPS MUST be positioned with the front panel at the to...

Страница 9: ...ef IOMNETPRXX01 GB 02 ENGLISH Load segment 1 green Service red Overload red Load segment 2 green Battery mode yellow Power ON green ON OFF button Test Alarm reset button 4 FRONT VIEW 4 1 2 Control pan...

Страница 10: ...e Slot for optional communication boards Slot for optional communication boards Main input socket IEC 320 Main input socket IEC 320 DIP Switches DIP Switches RS232 serial port RS232 serial port USB Po...

Страница 11: ...connector 6 1 3 Reinstall the UPS front panel Verify that the UPS is off and unplugged Remove the UPS front panel figure 6 1 1 Connect the battery connector figure 6 1 2 A small amount of arcing may...

Страница 12: ...pment and goes into Battery mode 7 2 TURNING THE UPS OFF To turn off the UPS press and hold the button for two seconds and then unplug the UPS from the power outlet If you do not unplug the UPS it rem...

Страница 13: ...FF 230 V 207 V 243 V OFF OFF ON 240 V 216 V 254 V ON ON Default position DIP Switch Settings 8 2 NETWORK TRANSIENT PROTECTOR The Network Transient Protector is located on the rear panel and has jacks...

Страница 14: ...gh Java Shutdown Client technology Web SNMP card 9 2 RS232 INTERFACE Communication with the server can take place directly via the RS232 interface In addition to local or networked shutdown it is poss...

Страница 15: ...correctly Check the power cord connections The UPS is in Standby mode Press and hold the button until you hear the UPS beep approximately two seconds to supply power to the connected equipment The wal...

Страница 16: ...to replace the battery Call your service represen tative if the problem persists Continuous beep UPS internal temperature is too high Shutdown is imminent Save your work and turn off your equipment Tu...

Страница 17: ...cuit protected Load connection socket IEC 320 4 10 A Battery Typical back up time 12 minutes Battery recharge Advanced charging for faster recovery Approximately 3 hours to 90 usable capacity at nomin...

Страница 18: ......

Страница 19: ......

Страница 20: ...UNITED KINGDOM Units 7A 9A Lakeside Business Park Broadway Lane South Cerney Cirencester GL7 5XL Tel 44 0 1285 863300 info ups uk socomec com OTHER COUNTRIES Tel 34 935 407 575 info ups europe socome...