2. HazarDS aND warNINgS

The term "device" used in the paragraphs below refers to the COUNTIS E13/E14.
The  assembly,  use,  servicing  and  maintenance  of  this  equipment  must  only  be  carried  out  by  trained,  qualified 
professionals.
SOCOMEC shall not be held responsible for failure to comply with the instructions in this manual.

2.1. risk of electrocution, burns or explosion

•   Only duly authorised and qualified personnel may work or install/uninstall the device.
•   The instructions are valid together with the specific instructions for the device.
•  The device is designed only for its intended purpose as set out in the instructions.
•   Only accessories authorised or recommended by SOCOMEC may be used in association with the device.
•   Before proceeding with installation, maintenance, cleaning, disassembly, connection, or maintenance work, 

the device and system must be cut off from the mains to avoid electrocution and damaging the system and 

device.

•  This device is not designed to be repaired by the user.
•  For any questions related to the disposal of the device, please contact SOCOMEC.

Failure to comply with the instructions of the device and this safety information can cause bodily injury, 

electric shock, burns, death or damage to property.

2.2. risk of damaging the unit

To ensure that the unit operates correctly, make sure that:

•   The unit is correctly installed.
•   There is a maximum voltage at the voltage input terminals of 288 VAC phase-neutral
•   The network frequency indicated on the device is observed: 50 or 60 Hz.
•  There is a maximum current of 80 A at the current input terminals (I1).

Failure to respect these precautions could cause damage to the unit.

2.3. responsibility

•   Assembly, connection and use must be carried out in accordance with the installation standards currently in 

force.

•   The unit must be installed in accordance with the rules given in this manual.
•   Failure to observe the rules for installing this unit may compromise the device's intrinsic protection.
•   The unit must be positioned within an installation which complies with the standards currently in force.
•   Any cable which needs to be replaced may only be replaced with a cable having the correct rating.

Содержание COUNTIS E13

Страница 1: ...COUNTIS E13 E14 Single phase energy meter Direct 80 A MODBUS EN Instruction manual www socomec com en countis e1x COUNTIS E13 COUNTIS E14 MID...

Страница 2: ...twork and to the loads 10 7 MID compliance 11 8 Communication 12 8 1 General information 12 8 2 RS485 rules 12 8 3 Communication structure 13 8 4 Communication tables 13 9 CONFIGURATION 14 9 1 Onscree...

Страница 3: ...3 EN COUNTIS E13 E14 545 869 A SOCOMEC 1 Documentation All documentation on the COUNTIS E13 E14 is available online at www socomec com en countis e1x...

Страница 4: ...d to be repaired by the user For any questions related to the disposal of the device please contact SOCOMEC Failure to comply with the instructions of the device and this safety information can cause...

Страница 5: ...of these instructions thoroughly before commissioning Check the following points as soon as you receive the package containing the unit The packaging is in good condition The unit has not been damage...

Страница 6: ...mmunication Bus 4 2 Functions Measures and displays total and partial energy Dual tariff management T1 T2 Electrical parameter measurements I U V f Power power factor RS 485 modbus communication MID v...

Страница 7: ...tive communication 4 Device malfunction Replace the device 5 Active pulse output 6 Setup menu 7 Main zone 8 Unit of measure 9 Inductive value 10 Capacitive value 11 Partial meters Flashing partial met...

Страница 8: ...capacitive energy Er kvarh Total active and reactive energy for each tariff T1 T2 Ea Er kWh kvarh Total apparent energy for each tariff T1 T2 Eap kVAh Total reactive inductive and capacitive energy f...

Страница 9: ...to the safety instructions section 2 Hazards and warnings page 4 Keep away from electromagnetic interference generator systems Avoid vibrations with accelerations greater than 1 g for frequencies lowe...

Страница 10: ...nnection to the electrical network and to the loads The COUNTIS E13 E14 are intended for single phase networks with neutral Pulse output 1 2 Optocoupler pulse outputs Terminals 1 2 must be supplied wi...

Страница 11: ...see 6 2 Connection to the electrical network and to the loads page 10 Fitting terminal covers After connecting the device ensure that the terminal covers are fitted properly and secured by the plastic...

Страница 12: ...C N 2 NC N n NC N 1 NC NC NC N n Programmable machines Programmable machines Other systems Other systems Repeater 8 2 RS485 rules A LIYCY shielded twisted pair must be used We recommend using a shield...

Страница 13: ...ply with the modbus protocol the inter character time must be 3 silences This means the time for 3 characters to be emitted so that the message is processed by the COUNTIS E13 E14 In order to use the...

Страница 14: ...page SETUP 3 sec Change a value digit SETUP pages realtime Confirm a value digit SETUP pages Double speed x2 0 5 sec Exit SETUP menu SETUP Menu 3 sec Start stop the displayed partial meter Partial met...

Страница 15: ...1 2 5 246 247 Communication speed 1200 2400 4800 9600 19200 38400 57600 115200 Communication parity n no o odd E even Communication stop bit 1 2 Reset energy Ea partial Tariff T1 T2 Ea par tial Ea pa...

Страница 16: ...tion address In SETUP mode see page 14 go to the Addr communication address screen Example changing the communication address to 247 3 x2 0 5 sec x2 x2 0 5 sec x4 x2 0 5 sec x2 x2 0 5 sec x1 Baudrate...

Страница 17: ...__________ Tariff 2 Imported and exported active energy Total imported and exported inductive reactive energy Partial exported active energy by tariff Checksum of metrological firmware ______________...

Страница 18: ...d active energy tariff 1 Exported active energy tariff 1 Imported reactive energy tariff 1 Exported reactive energy tariff 1 Imported active energy tariff 2 Exported active energy tariff 2 Imported re...

Страница 19: ...otal exported active energy Total apparent energy Total imported inductive reactive energy Total exported inductive reactive energy Total imported capacitive reactive energy Total exported capacitive...

Страница 20: ...artial active energy for tariff T2 Partial imported active energy Exported partial active energy for tariff T1 Exported partial active energy for tariff T2 Partial exported active energy Partial impor...

Страница 21: ...21 EN COUNTIS E13 E14 545 869 A SOCOMEC 10 3 1 Starting up the partial energy meter 3 3 10 3 2 Stopping the partial energy meter 3 3 10 3 3 Resetting the partial energy meter to zero 3 x1 3...

Страница 22: ...EC 10 4 Detailed view of the menu info Metrological firmware version Non metrological firmware version Checksum of metrological firmware Checksum of non metrological firmware Installed communication p...

Страница 23: ...appears if there are connection or malfunction errors 11 1 Malfunction If you see this message the meter has malfunctioned and must be replaced 12 Assistance Causes Solutions Device not working Check...

Страница 24: ...consumption 0 5VA Startup current Ist 20mA Minimum current Imin 0 25A Transition current Itr 0 5A Reference current Iref 5A Permanent overload lmax 80A Intermittent overload 30 Imax for 1 2 cycle OVER...

Страница 25: ...ge 1 display 4 digit 000 0 999 9 V Realtime current 1 display 4 digit 00 00 99 99 A Power factor 1 display 4 digit 0 001 1 000 Frequency 1 display 4 digit 45 00 65 00 Hz COMMUNICATION RS485 2 wires sh...

Страница 26: ...of non metrological firmware tAr Tariff menu tot Total menu P rt Partial and realtime readings menu SEtuP Setup menu Addr Slave address bAu Communication speed in bauds bits per second Prty Communicat...

Страница 27: ...27 EN COUNTIS E13 E14 545 869 A SOCOMEC...

Страница 28: ...545 869 A FR 02 17 Non contractual document 2016 Socomec SAS All rights reserved CORPORATE HQ CONTACT SOCOMEC SAS 1 4 RUE DE WESTHOUSE 67235 BENFELD FRANCE http www socomec com...

Отзывы: