TROUBLESHOOTING
N.B.: Never try to repair the dehumidifier yourself. Always contact our authorised
after-sales service for repairs. Before doing so, please check the following points.
Problem
Analysis
After starting up, the
dehumidifier does not work
• Is the water boxwater container inserted properly
installed into the machine?
• Is the power plug inserted fullyplugged firmly intoto the
socket?
• Is the fuse or current breaker burntintact?
• Is there a power cut?
• Is the water container full?
Dehumidifying is under
capacity
• Is the air filter blocked?
• Is the room temperature too low?
• Is the air inlet or outlet blocked?
Humidity cannot be reduced
below 65 %
• Are the windows/doors opened too often?
• Is a heater or other devices producing steam running ?
• Is the room area too large?
Abnormal noise
• Is the floor uneven?
• Is the dehumidifier positioned correctly?
• Is it off balance?
There is a mouldy smell after
start up
• A disagreeable smell is possible for when moisture is
drawn out of the walls.
There is a sound of flowing
water
• This noise is produced by flowing of the cooling agent
and is therefore normal.
SPECIFICATIONS
Model XE510
Power Supply: 220-240 V 50 Hz
Dehumidifying capacity
30°C RH 80% (litre/day): 10
Power (W): 180
Current (A): 0.9
Input power at peak load (W): 240
Input current at peak load (A): 1.1
Volume of air circulated (m/h): 110
Noise (dB(A)): 45
Coolant: R134a (120 g)
Water container capacity (litre): 3.5
Net weight (kg): 12
Dimensions (L x W x H)
245 x 297.5 x 552 mm:
Operating norm: JB/T7769-1995
N.B.:
1. Contact our after sales service
to ensure any maintenance work
is carried out by professional
technicians.
2. Should the power cord be damaged,
contact the authorised after sales
service.
3. This humidifier is for usage in closed
rooms
Subject to change without prior notice.
XE510 DEHUMIDIFIER