7
Know Your Commercial Grade Pressure Washer
Read the owner’s manual and safety rules carefully before operating the pressure washer. Compare the illustration below to
the unit in order to familiarize yourself with the location of the various controls and adjustments. Save this manual for future
reference.
Technical Data
Rated Voltage ................................................ 120 V ~ 60 Hz
Motor ............................................................. 13.5 amp
Max Water Inlet Temperature ........................ 104ºF/40ºC
Max Water Inlet Pressure .............................. 0.7 MPa
Rated Flow .................................................... 1.8 GPM
Max Flow* ...................................................... 2 GPM
Max Pressure* ............................................... 1300 PSI
Rated Pressure .............................................. 1000 PSI
Detergent Tank Capacity ............................... 1 Gal (3.8 L)
High-pressure hose Length ........................... 25 ft (7.6 m)
Power Cord Length ....................................... 35 ft (10.7 m)
Weight ........................................................... 57.3 lbs (26 kg)
1. Trigger gun
2. Trigger gun holder
3. High-pressure hose
4. Spray wand
5. Handle
6. Pump cover
7. Pump
8. Detergent tank cap
9. Detergent tank
10. Lower handle frame
11. Wheel (2)
12. Oil measuring plug
13.
On/Off switch
14. Power cord with GFCI
15. Upper handle frame
16. On-board nozzle storage
17. Power cord holder
18. High-pressure hose connection
19. Trigger
20. Safety lock
21. Soft grip
22. High-pressure hose holder
23. 0º Quick-Connect nozzle (orange)
24. 15º Quick-Connect nozzle (yellow)
25. 25º Quick-Connect nozzle (green)
26. 40º Quick-Connect nozzle (gray)
27. Soap Quick-Connect nozzle (black)
28. Adjustable pressure valve
29. Garden hose adapter/connection
30. Water outlet/high-pressure hose
connection
31. Detergent tube
32. Oil level window
33. Detergent tank screw (2)
34. Quick-connect collar
35. Spray wand protector
R
R
1
2
3
4
5
6
7
8
9
10
11
12
13
14
16
17
18
19
20 21
22
23
24
25
26
27
28
29
30
31
32
34
35
15
33
* Max rating per CSA test standards. Maximum internal pressure is 1300 PSI and flow is 2 GPM.
Under typical load, working pressure is 1000 PSI and flow is 1.8 GPM.