Chapter 4 – Safety Devices
14
TB42J – 0172310
The gates close automatically after entering or exiting
the platform. The gate is part of the guardrail system and
must be securely fastened after entering the platform.
Lanyard Anchors
Two lanyard anchors for fall restraint anchorage are pro-
vided below the upper controls at the front of the platform
(refer to Figure 4.4).
Note
The lanyard anchors are not for lifting or tying the ma-
chine down.
All personnel in the platform must connect their fall re-
straint device to a lanyard anchor before raising the plat-
form. Do not use the aerial platform for
personal fall ar-
rest
anchorage.
Ground Fault Circuit Interrupter
The electrical power outlet at the platform contains a
ground fault circuit interrupter (GFCI) to provide protec-
tion for personnel.
Figure 4.6 – Electrical Power Outlet
Tilt Alarm
If the aerial platform chassis is out of level more than five
degrees when the main boom is raised or extended, an
alarm will sound. The tilt alarm is located under the upper
control panel.
A
Danger
The aerial platform can tip over if it becomes un-
stable. Death or serious injury can result from a tip-
over accident. Do not drive or position the aerial
platform for elevated use near any drop-off, hole,
slope, soft or uneven ground, or other tip-over haz-
ard.
Retract and lower the main boom and then drive to a level
surface when the tilt alarm sounds.
Ground Controls Switch
The ground controls switch (refer to Figure 4.1) prevents
boom and platform movement if a control switch on the
lower control panel is accidentally moved.
Hold the switch in the on position to operate the machine
from the lower controls.
Platform Foot Switch
Stepping down on the platform foot switch (refer to Figure
4.4) activates the upper controls.
Figure 4.4 – Platform
The foot switch must be engaged and a control must be
moved to operate the boom, drive, and/or platform from
the upper controls.
Guardrails
The guardrail system includes a top rail, mid rail, and
toeboards around the sides of the platform (refer to Fig-
ure 4.4).
A gravity gate (refer to Figure 4.4) or an optional swinging
gate (refer to Figure 4.5) allows for access to the plat-
form.
Figure 4.5 – Platform
Swinging
Gate
Toeboard
Top Rail
Mid Rail
Gravity
Gate
Lanyard
Anchors
Platform Foot
Switch
Содержание TB42J
Страница 11: ...Chapter 2 Specifications TB42J 0172310 7 Engine Oil Viscosity Cummins B3 3 Deutz F3L 2011F...
Страница 12: ...Chapter 2 Specifications 8 TB42J 0172310...
Страница 28: ...Chapter 6 Controls 24 TB42J 0172310...
Страница 42: ...Chapter 7 Prestart Inspection 38 TB42J 0172310...
Страница 44: ...Chapter 7 Prestart Inspection 40 TB42J 0172310...
Страница 50: ...Chapter 8 Operation 46 TB42J 0172310...
Страница 58: ...Chapter 10 Emergency Operation 54 TB42J 0172310...
Страница 64: ...Chapter 11 Troubleshooting 60 TB42J 0172310...
Страница 66: ...Appendix A Glossary TB42J 0172310...
Страница 68: ......