Snorkel MHP15/44 Скачать руководство пользователя страница 31

Ground Control Box

Con trols  for op 

er 

at 

ing the MHP15/44 from the

ground, (lower con trols) are lo cated on the right
side of the turn ta ble.

Lower controls:

Emergency stop switch

Platform/ground selector switch

Choke

Master key switch

Boom speed switch

Stabiliser/boom selector switch

Lower boom switch

Upper boom switch

Jib boom switch

Slew switch

Lift enable indicator

1.

Emergency Stop

: Press the EMERGENCY

STOP switch cover down, at any time, under
any conditions, and the entire machine
stops, and nothing moves. This emergency
stop switch cover must be up and the switch
turned on for anything on the MHP15/44 to
work.

2.

Platform/Ground Selector

 : Must be in the

GROUND position (down) for the ground
control box to work. The switch MUST be in
the PLATFORM position (up) for the platform 
control box to work.

3.

Choke/Cold Start

: Hold the switch UP while

you start an engine that is at ambient air
temperature (a "cold" engine). This will choke 
the engine.

4.

Master Key Switch

: This switch works like

an automobile ignition switch. Hold it at
START until the engine starts, then release it 
to ON. (-) Turn the 

Master Key Switch 

to

OFF (O) if the platform is to stay in one
position for a long time, that will turn the
engine off and save fuel.

5.

Boom Speed

: This control determines how

fast the booms move. Set it to SLOW (turtle)
until you are very familiar with the way the
machine works or if the platform is working in 
dangerous or cramped surroundings.

6.

Stablizer / Boom Selector Switch

Must be in Stablizer (outrigger) position
(down) for the outriggers to work. Once
outriggers are down and set the switch must
be placed in the boom (up) position for the
booms to work. 

Con trol switches  7 through 10 are the plat form 
mov ing switches. Each is a three po si tion, mo men -
tary con tact, nor mally OFF switch.

7.

Lower Boom 

: UP raises the lower  boom.

DOWN lowers the lower boom.

8.

Upper Boom

: UP raises the upper boom.

DOWN lowers the upper boom.

9.

Jib Boom

: UP raises the jib boom. DOWN

lowers the jib boom.

10.

Slew

: LEFT rotates the entire turntable and

boom to the left. RIGHT rotates the entire
turntable and boom to the right.

11.

Lift Enable

: The platform can only be raised

when this light is lit. When this light is not lit
the platform will not raise because the
outriggers are not properly set.

Ground Control Box Controls

Lower Control Box Controls

page  6 - 2

MHP15/44 – 12459A

6. Controls

Содержание MHP15/44

Страница 1: ...Engine Powered Gasoline Diesel Battery Electric Operator s Manual P N 12459A May 2005...

Страница 2: ...ty period of the machine upon which the part was installed THIS WARRANTY EXCLUDES AND SNORKEL DOES NOT WARRANT 1 Engines motors tires and batteries which are manufactured by suppliers to Snorkel who f...

Страница 3: ...f the MHP Such contact could make your body a conductor to the other object creating an electrical shock hazard re sulting in SERIOUS INJURY or DEATH DO NOT attempt to enter or leave the MHP until you...

Страница 4: ...nce to energized exposed or insulated power lines Voltage range Minimum safe approach distance phase to phase Feet Meters 0 to 300V Avoid contact over 300v to 50kv 10 3 05 over 50kv to 200kv 15 4 60 o...

Страница 5: ...All information in this manual is based on the latest product information at the time of publication Snor kel reserves the right to make product changes at any time without obligation Safety Alerts A...

Страница 6: ...gulations Ultimate compliance to OSHA reg ulations is the responsibility of the user and their employer ANSI Standard A92 2 2001clearly identifies requirements of all parties who might be involved wit...

Страница 7: ...HP15 44 3 4 Booms identification 3 5 Nomenclature And Serial Numbers 3 5 Right side view of machine 3 5 Left side view of machine 3 6 4 Gauges Hourmeter 4 1 Level Bubble 4 1 Hydraulic Oil Level 4 1 5...

Страница 8: ...9 1 Operation From Ground Control Box 9 2 10 Stowing and Transporting Stowing 10 1 The correct stowed position is shown here 10 1 Transporting 10 1 Trailering 10 1 Securing to a Transport Vehicle 10...

Страница 9: ...learance from an energised conductor Do not go closer than the minimum safe approach distance as defined by ANSI ANSI publications define minimum distances that must be observed when working near bus...

Страница 10: ...platform Always look in the direction of travel Drive with care and at speeds compatible with the work place conditions Use caution when driving over rough ground on slopes and when turning Do not eng...

Страница 11: ...n trance to the platform Do not carry loads from any point outside of the platform Make sure that all protective guards cowlings and doors are in place and secure Be sure the guard rail system includi...

Страница 12: ...gines use the correct fuel grade for the operating season Batteries Charge batteries in a well ventilated area free of flame sparks or other hazards that might cause fire or explosion Batteries give o...

Страница 13: ...ELF AND OTHERS TO DEATH OR SERIOUS INJURY 0323897 1 2 YOU HAVE BEEN TRAINED IN THE SAFE OPERATION OF THIS DEVICE AND HHHH YOU KNOW AND FOLLOW THE SAFETY AND OPERATING RECOMMENDATIONS CONTAINED IN THE...

Страница 14: ...he boom platform descends Keep out from under the descending boom and platform DANGER 12406 TOWING SPEED 80KPH 12424 50MPH MAXIMUM FIT BOOM CRADLE LOCK PIN FOR TRAVELLING 1772 002K OPERATORS CHECKLIST...

Страница 15: ...rds before commencing to use the appliance whilst working or travelling the appliance in the vicinity of live electrical apparatus 3m for voltages up to 132 000 6m for voltages above 132 000 and up to...

Страница 16: ...CY STOP switch cover down at any time under any conditions and the entire machine stops and nothing moves This emergency stop switch cover must be up and the switch turned on for anything on the MHP15...

Страница 17: ...swinging gate is in place Foot switch Figure 2 6 Foot Switch The foot switch prevents the platform from moving if something accidentally pushes one of the plat form moving controls on the platform co...

Страница 18: ...ad from the platform box and reset the RCD at the base If the problem persists call a trained service techni cian Flashing light Figure 2 9 Flashing Light The flashing light alerts people that the MHP...

Страница 19: ...page 2 4 MHP15 44 12459A 2 Safety Devices...

Страница 20: ...6 3 Maximum wind speed 12 5m s 45kph 28mph Turntable rotation 540O non continuous or 360O continuous Power source std Gasoline engine 5 5hp Hydraulic system Proportional electro hydraulic Stabilisatio...

Страница 21: ...Bore x Stroke 68 x 45 mm 2 7 x 1 8 in Max output 4 kW 4 000 rpm Max torque 1 1 kg m 8 0 ft lb 2500 rpm Fuel gasoline Fuel Grade automotive gasoline unleaded or lowleaded preferred Fuel consumption 23...

Страница 22: ...Overall Dimensions MPH15 44 MHP15 44 12459A page 3 3 3 Specifications 1 80m 58m 4 79m 7 43m 7 61m Includes optional rotator 41m 1 98m...

Страница 23: ...459A 3 Specifications 16 15 14 13 12 9 6 5 4 3 2 1 METRES 11 10 8 7 52 5 49 2 45 9 42 7 39 4 36 1 32 8 23 19 7 16 4 9 8 6 6 3 2 FEET 29 5 26 2 13 1 METRES FEET 4 3 2 1 0 1 2 3 4 5 6 7 5 8 16 4 13 1 9...

Страница 24: ...VIN Number Jib boom Levelling Quadrant Upper boom Booms identification Nomenclature And Serial Numbers Jockey wheel Tow coupling Draw bar Outriggers 4 Trailer Outrigger controls Engine cover Column G...

Страница 25: ...page 3 6 MHP15 44 12459A 3 Specifications Oil tank cover Outrigger cylinder Hand brake Upper cylinder Lower cylinder Jib Cylinder Left side view of machine...

Страница 26: ...n the trailer base Watch the bubble while you set the outriggers Lower the out riggers front ones first one at a time just enough to center the bubble in the circle on top of the guage When the bubble...

Страница 27: ...page 4 2 MHP15 44 12459A 4 Gauges...

Страница 28: ...only one circuit breaker on a standard MHP15 44 that is accessible to the operator Its purpose is to protect the electrical circuits from electrical overloads When the circuit breaker trips pops out p...

Страница 29: ...page 5 2 MHP15 44 12459A 5 Automatic Shut offs and Circuit Breakers...

Страница 30: ...11420 LIFT ENABLE CHOKE STABILISER PLATFORM BASE BOOMS Platform Controls Ground Controls Stabiliser Controls 12385 10 LIFT ENABLE JIB BOOM UPPER BOOM LOWER BOOM ROTATE PLATFORM SLEW SPEED CONTROL EME...

Страница 31: ...to ON Turn the Master Key Switch to OFF O if the platform is to stay in one position for a long time that will turn the engine off and save fuel 5 Boom Speed This control determines how fast the boom...

Страница 32: ...position for a long time that will turn the engine off and save fuel 4 Boom Speed This control determines how fast the booms move Set it to SLOW turtle until you are very familiar with the way the mac...

Страница 33: ...s Option Self levelling Stabiliser Controls 1 Auto Manual Switch Select either A or M for automatic or manual operation of the stabilizers 2 Auto Raise Lower Switch Select either up or down to raise o...

Страница 34: ...l level between dipstick lines Fuel leaks Visually inspect hoses and connections Operator s manual Check that it is in the holder on the machine Wiring harnesses Visually inspect installation conditio...

Страница 35: ...sually inspect the Honda fuel tank and the engine compartment for any signs of leaking spilt fuel Engine Oil Level Figure 7 4 Engine Oil Level Remove the oil filler cap and wipe the dipstick clean Ins...

Страница 36: ...ck the hydraulic oil level Completely lower the booms and ensure the stabi lizers are in the stowed position Figure 7 9 Hydraulic Oil Level The hydraulic oil level should be between the two marks on t...

Страница 37: ...tical pin retainer bolts have lock tab washers fit ted they should all be present and not damaged in any way Figure 7 13 Wheel Nuts Pay particular attention to all of the wheel nuts and bolts None sho...

Страница 38: ...nd does not jam Platform Guardrails Figure 7 20 Platform Guardrails Visually inspect the platform guardrails to see that none of the tubing has been cut out removed or deformed in any way Visually che...

Страница 39: ...on and the Platform ground Selector must be set to ground To slew with the manual emergency lower valve already open select the required direction on the slew toggle switch NOTE The manual emergency...

Страница 40: ...kel dealers Standard placards and decals See page 7 8 for the following items MHP15 44 12459A page 7 7 7 Daily Inspection and Maintenance CAUTION No Part No Description Req 1 9972 MHP Serial number pl...

Страница 41: ...age 7 8 MHP15 44 12459A 7 Daily Inspection and Maintenance 7 4 2 19 12 15 15 1 28 9 13 17 21 25 29 18 23 12 14 20 24 25 19 20 20 20 6 9 22 x 8 28 21 x 4 11 x 4 16 19 10 30 3 26 8 27 Inspection drawing...

Страница 42: ...m the ground control box and only when the booms are in the stowed position The MHP15 44 is not Electrically Insulated Death or Serious Injury to operating personnel can occur if the machine should co...

Страница 43: ...tart and hold it there until the engine starts or for a maximum time of 6 seconds When the engine starts release the key and the choke switch if you used it see Figure 8 3 If the engine does not start...

Страница 44: ...ensure that all of the foot plates are firmly on the ground the machine is level and the lift enable light is ON before entering the platform Starting From Platform Control Box Before you begin to ope...

Страница 45: ...trical conductors Maintain the M S A D Minimum Safe Approach Distance to energized power lines See the Electrical Hazard section in this manual for a complete explanation of the hazards concerning ele...

Страница 46: ...ough will produce the movement as indicated by the il lustration s to the right Figure 8 10 Movement Control Platform Control Box You must be stepping on the platform foot switch when you use any of t...

Страница 47: ...ation procedures will work at the platform control box Figure 9 1 1 The Master Key Switch must be ON see Figure 9 1 2 The Emergency Stop switch must be ON see Figure 9 1 3 The Platform Ground Selector...

Страница 48: ...gency lowering valve the Master Key Switch and Emergency Stop switch must be on and the Platform Ground Selector must be set to ground The slew direction can then be selected using the slew switch see...

Страница 49: ...in 4 Insert upper boom pin in place and ensure the snap pin is correctly locked in place through the boom pin see Figure 10 3 Figure 10 3 Upper Boom Lock Pin If using the upper controls go now to the...

Страница 50: ...and ensure the latching mechanism is working and has latched 5 Connect the break away chain to the towing vehicle unset the reversing lock on the tow coupling 6 Check that the bolt or D Clamp on the...

Страница 51: ...nd the 24V DC motor to give a Bi energy option Work Lights Rubber encased work lights can be fitted to the platform guardrails The lights are swivel mounted and each has its own switch Flashing Light...

Страница 52: ...page 11 2 MHP15 44 12459A 11 Options...

Страница 53: ...methods Battery Lead Acid UN 2794 Extinguishing media Dry chemical foam or CO2 Special fire fighting procedures Use positive pressure self contained breathing ap paratus Unusual fire and explosion haz...

Страница 54: ...elastomer Product may melt after ignition to form flammable liquid Burning produces intense heat dense smoke and toxic gases such as carbon monoxide oxides of nitrogen and traces of hydrogen cyanide S...

Страница 55: ...uct as possible Dispose of non recyclable material as a RCRA hazardous waste by such methods as incineration complying with federal state and local regula tions Liquefied Petroleum Gas UN 1075 Extingu...

Страница 56: ...in smallest area possible Recover as much of the product itself as possible by such methods as vacuuming followed by soak ing up of residual fluids by use of absorbent materi als Remove contaminated...

Страница 57: ...ne If it will not start refer the problem to a qualified service technician 3 Loose battery terminals Tighten battery leads at battery Engine cranks but will not start 1 Out of fuel Fill the engine wi...

Страница 58: ...page 13 2 MHP15 44 12459A 13 Operator s Troubleshooting...

Страница 59: ...ol Decals Locations 6 1 D Daily Inspection and Maintenance Table 7 1 E Electrical Electrocution 1 3 8 1 Electrical Hazard Warning see Electrical Hazard page i Emergency lower 7 6 Emergency Operation 9...

Страница 60: ...ty Decals and Placards 1 4 Safety Devices Bubble level 2 2 Emergency Stop Switches 2 1 Flashing light 2 3 Foot switch 2 2 Gravity gate 2 2 Guardrails 2 2 Lanyard anchor points 2 1 RCD ELCB AC outlet 2...

Страница 61: ...Working Envelope MHP15 44 3 4 MHP15 44 12459A index 3 Index...

Страница 62: ......

Отзывы: