Snorkel 16GTRD Скачать руководство пользователя страница 29

Specifications

T40RT/T46JRT – 1430001 

27 

Specifications – T46JRT

Aerial Platform

Working height 

15.8 m (52

)

Maximum platform height 

14 m (46

)

Horizontal reach 

12.2 m (40

)

Main boom

   Articulation 

-15.5° to +72°

   Extension 

4.5 m (15

)

Jib boom

   Reach 

1.8 m (6

)

   Articulation 

-68° to +68° 

Turntable rotation 

360° continuous

Turning radius, outside 

4.6 m (15

)

Turning radius, inside 

1.4 m (4

 6

)

Tail swing 

83.8 cm (33

)

Wheelbase 

2.44 m (8

)

Ground clearance 

35.5 cm (14

)

Maximum wheel load 

3,900 kg (8,600 lbs)

Maximum hard surface contact pressure

 

5.13 kg/cm² (73 psi)

Weight, EVW

   Approximate 

6,396 kg (14,100 lbs)

Width 

2.44 m (8

)

Stowed length 

8.6 m (28

 5

)

Stowed height 

2.4 m (7

 11

)

Platform

Dimensions

   Standard Aluminum 

99 cm x 244 cm (39

 x 96

)

     Rated work load 

227 kg (500 lb)

   Optional Steel 

99 cm x 183 cm (39

 x 72

)

     Rated work load 

227 kg (500 lb)

Rotation 

180 degrees

Maximum number of occupants 

2 people

Optional AC generator 

110 V

Optional AC generator 

220 V

Optional AC generator 

220 V, 3-phase, 12 kw

Function Speed

Turntable rotation   

   Clockwise 

110 to 115 sec  0.7 m/s (2.29 ft/s) 

   Counterclockwise  110 to 115 sec  0.7 m/s (2.29 ft/s)

Main boom

   Up 

43 seconds minimum  0.36 m/s (1.18 ft/s)

   Down 

43 seconds minimum  0.36 m/s (1.18 ft/s)

   Extend 

31 seconds minimum

   Retract 

29 seconds minimum

Jib

     Up 

20 seconds minimum

     Down 

20 seconds minimum

Platform rotation 

17 to 22 seconds

Drive

   

 High, booms stowed  6.8 km/h [1.9 m/s] (4.25 mph)

    Mid, booms stowed 

3.2 km/h [0.89 m/s] (2 mph)

    Low, booms raised/extended 

 

1.2 km/h [0.33 m/s] (0.75 mph)

Drive System

Standard 

Four wheel drive

Gradeability 

40%

Axle  

front oscillating

  Vertical wheel travel 

22.8 cm (9

 

Tires

Foam filled 

355/55 D625, 14 ply

Electrical System

Voltage 

12 V DC negative chassis ground

Source 

One - 12 V 550 CCA battery

Fluid recommended 

distilled water

Hydraulic System

Pressure

   Drive circuit maximum 

41,368 kPa (6,000 psi)

   Boom circuit maximum 

19,305 kPa (2,800 psi)

Reservoir capacity 

140 l (37 US gal)

System capacity 

170 l (45 US gal)

Maximum operating temperature 

93°C (200°F)

Hydraulic fluid recommended

   Above 0°C (32°F) 

   Mobil EAL Envirosyn 46 H

   Consistently between -17°C (0°F) and 0°C (32°F) 

 

Mobil EAL Envirosyn 32 H

 

Engine

Diesel 

Kubota V1505-T

Fuel Tank Capacity

Diesel 

170 l (45 US gal)

Ambient Air Temperature Operating Range

Celsius 

-18°C to 43°C

Fahrenheit 

0°F to 110°F

Maximum Wind Speed

Gust or steady 

45 km/h (28 mph)

Vibration

 

 

 

 less than 2.5 m/sec

2

Sound Power Level

   

 

     103 dB(A)

Sound Pressure Level

 – at work station       91 dB(A)

Group Classification

Heavy Duty – intended life 

100,000  load cycles

Working Envelope

0

3.0 

(10)

9.1 

(30)

6.1 

(20)

12.2 

(40)

6.1 

(20)

0

3.0 

(10)

9.1 

(30)

12.2 

(40)

15.2 

(50)

3.0 

(10)

15.2 

(50)

18.3 

(60)

Meters 

(Feet)

Содержание 16GTRD

Страница 1: ...December 2012 Part Number 1430001 MANUAL OPERATORS Serial number 000000 and after Replaces June 2012...

Страница 2: ......

Страница 3: ...ation Switch T46JRT 11 Platform Level Switch 11 Platform Rotation Switch 11 Engine Emergency Power Switch 11 Horn Switch 11 Platform Foot Switch 11 AC Generator Switch 11 Hydraulic Oil Warm Up Switch...

Страница 4: ...penprufung Zertifikat Nr Examen type CE Numero de Certificat Inspeccion tipo CE Numero de certificado Attestato di certificazione CE nr Onderzoek van het type EC Certificaatnummer EU typkontroll Certi...

Страница 5: ...ut only ever when in the stowed position The machine must not be used for a job of work until the wheels have been flipped back round to their correct position 180 To flip the wheel back to the correc...

Страница 6: ...is elevated STOP carefully lower platform Move machine to a firm level surface Climbing up the railing of the platform standing on or stepping from the platform onto buildings steel or prefab concrete...

Страница 7: ...NUMBERS from the equipment nameplate Should the nameplate be missing the SERIAL NUMBER is also stamped at the rear of the chassis Right Side Chassis Lower Controls Upper Controls Operator s Manual St...

Страница 8: ...ff and back on resetting the system At that time the machine functions are operational Caution The emergency power system is for emergency low ering and stowing only The length of time the pump can be...

Страница 9: ...re all personnel stand clear while operating the aerial platform Controls to position the platform are located on the lower control panel on the turntable and on the upper control panel in the platfor...

Страница 10: ...e When the ambient temperature range is 10 C 50 F to 5 C 23 F press and hold the preheat button for five seconds before starting the engine When the ambient temperature is below 5 C 23 F press and hol...

Страница 11: ...the upper control panel Note Machine functions are not operational while using the hydraulic warm up system To warm up the hydraulic fluid from the lower controls 1 Start the engine from the lower con...

Страница 12: ...erate the aerial platform Push the emergency stop button inward when the upper controls are not in use to protect against unin tentional operation Drive Boom Selector Switch The drive boom selector sw...

Страница 13: ...y low ering and stowing only The length of time the pump can be operated depends on the capacity of the bat tery Do not use this system for normal operation Hold the engine emergency power switch down...

Страница 14: ...he proper level 4 Check that all guardrails are in place and all fasteners are properly tightened 5 Inspect the machine thoroughly for cracked welds and structural damage loose or missing hardware hyd...

Страница 15: ...sing or loose parts 5 Test each machine function jib platform level plat form rotate elevation rotation extension from the lower control station by holding the ground operation switch up while operati...

Страница 16: ...does not flow well and may cause delay in response to control movement Cold hydraulic oil may also cause cavitation and pump damage Hydraulic System Cold Weather Warm Up Some machines may have a hydra...

Страница 17: ...perating the boom and turntable control toggle switches 6 Release the function toggle switch to stop move ment 7 Place the ground operation switch in the off position when no functions are being opera...

Страница 18: ...t When the turntable is rotated from the stowed position with the booms to either side of or in front of the chassis the direction of control movement does not correspond with the direction of chassis...

Страница 19: ...onnector on the right side of the chassis Unplug the source of power before moving the aerial platform AC Generator The optional generator supplies power to the electrical outlet only when the engine...

Страница 20: ...s Key Switch to OFF and remove the key to prevent unauthorized operation Emergency Lowering Warning If the platform should fail to lower NEVER climb down the elevating assembly Stand clear of the elev...

Страница 21: ...ock Caution Ratchets winches and come alongs can produce enough force to damage machine components Do not over tighten the straps or chains when securing the aerial platform to the transport vehicle 3...

Страница 22: ...engine tray Oil Level Check the engine oil level before starting the engine so the oil has drained to the pan The proper oil level is between the add and full marks on the dipstick The distance betwe...

Страница 23: ...at the specified intervals and after prolonged periods of storage before returning the machine to ser vice Inspection and maintenance shall be performed by personnel who are trained and familiar with...

Страница 24: ...er Control Station Operating controls Proper operation Emergency stop and emergency power Shuts off lower controls proper operation Level Sensor Sounds tilt alarm Flashing Light Proper operation All M...

Страница 25: ...Decal Location LOW ER CONTROLS ENGINE DIPSTICK INSIDE ON CIRCUIT BREAKER PANEL ANSI ONLY CE ONLY ANSI ONLY CE ONLY T46JRT ONLY INSIDE ON HYDRAULIC RESERVOIR INSIDE ABOVE GREASE FITTING INSIDE ON DIESE...

Страница 26: ...rief operating instructions swedish 0162328w 2 Decal additional operating instructions swedish ITEM PART NO QTY DESCRIPTION 0162329d 2 Decal brief operating instructions dutch 0162328d 2 Decal additio...

Страница 27: ...10e 3 Decal DNGR ROTATING PARTS english 0151410f 3 Decal DNGR ROTATING PARTS french 0151410p 3 Decal DNGR ROTATING PARTS spanish 0151410w 3 Decal DNGR ROTATING PARTS swedish 0151410d 3 Decal DNGR ROTA...

Страница 28: ...1 18 ft s Down 43 seconds minimum 0 36 m s 1 18 ft s Extend 32 to 35 seconds Retract 32 to 37 seconds Platform rotation 17 to 22 seconds Drive High booms stowed 6 8 km h 1 9 m s 4 25 mph Mid booms st...

Страница 29: ...nimum Retract 29 seconds minimum Jib Up 20 seconds minimum Down 20 seconds minimum Platform rotation 17 to 22 seconds Drive High booms stowed 6 8 km h 1 9 m s 4 25 mph Mid booms stowed 3 2 km h 0 89 m...

Страница 30: ...l Distributore locale EUROPE MIDDLE EAST AFRICA ASIA PHONE 44 0 845 1550 058 FAX 44 0 845 1557 756 NORTH SOUTH AMERICA PHONE 1 785 989 3000 TOLL FREE 1 800 255 0317 FAX 1 785 989 3070 AUSTRALIA PHONE...

Отзывы: