5.1.2.1
SETTING PORT 1 as RS422
NEBULA CONTROLLER
Figure 23: Configuration of Port 1 to RS422 with 2449 Controller
Detail of the port configuration (i.e. General Switcher or Multidrop) is controlled and configured via the
Nebula editor. For details refer to Nebula documentation.
If using a 2450 controller port configuration and control is via Workbench software, no headers or
switch settings are required. Refer to Workbench documentation for details.
NUCLEUS CONTROLLER
The Nucleus controller does not have any jumper of switch settings configuration should be via the
Workbench database.
5.1.2.2
PORT 1 CONNECTION OPTIONS
An RJ45 Connector is not standard for RS422 communications, if a 9 Way interface is required Snell
provide an adapter (Part Number HW-RJ45D9SA) which converts the RJ45 socket to a 9Way D-
Type socket.