5.14.3 GPI 1 and 2 (Output)
When the GPI is configured as an output, this enables you to choose an action that will
produce an output signal at the GPI connector. The GPI output will be driven to low when the
action is true or high when false.
•
Freeze Ch1:
GPI output will be driven low when freeze is selected, and will return
high when freeze is deselected.
•
Black Ch1:
GPI output will be driven low when Test Patterns – Black is selected on
the Output screen, and will return high when Test Patterns – Black is deselected.
•
Pattern Ch1:
GPI output will be driven low when Test Patterns – Ramp is selected on
the Output screen, and will return high when Test Patterns – Ramp is deselected.