background image

Batteries Installation

Start the Instrument / Menu Setting

Under off status, press button        , device and  laser 

get starting simultaneously and stand by for 

measurement.

Battery Installation and Replacement

Turn On/Off the Instrument 

Under on status, long press button        for 3 seconds 

to turn the device off. The device can also be shut off 

without any operation for 150 seconds.

Discharge the battery door on the back of device, and 

place battery according to correct polarity, then cover 

the battery door.
Only 1.5 V AAA alkaline battery is applied to the meter.
If not used for a long time, please take out the battery to

avoid battery corrosion to meter body.

- 3 -

Содержание SW-G10S

Страница 1: ...SW G4S SW G6S SW G8S SW G10S Laser Distance Meter User s Manual...

Страница 2: ......

Страница 3: ...out of reach of children and avoid using by any irrelevant personnel It is strictly prohibited to shoot eyes or other parts of body with the laser It is not allowed take the laser to shoot any object...

Страница 4: ...n Measuring Area Volume Pythagorean Mode Turn off Remove Reference Point Unit Switch Addition Subtration Save Power Supply Area Volume and Pythagorean Laser on Maximum Auxiliary Display Record Minimum...

Страница 5: ...t Under on status long press button for 3 seconds to turn the device off The device can also be shut off without any operation for 150 seconds Discharge the battery door on the back of device and plac...

Страница 6: ...et to turn on and off automatically The back light can be on for 15s while operating and it will be shut off automatically in 15s when there is no operation to the device Keys sound When the rangefind...

Страница 7: ...y short press of the button under measuring mode press the button again for single measurement of length then the measured results displayed in the major display area Self Calibration This function ca...

Страница 8: ...ion for volume measuring Press for length Press again for width Press thirdly for height The resent measuring result of length is showed in the auxiliary display area Press clear off the result and me...

Страница 9: ...three times to enter Pythagoras mode the hypotenuse of blinking Press measure the length of hypotenuse a Press measure the length of one leg b Device the length of another leg x 1 Calculate the secon...

Страница 10: ...f another side c Device calculates the length of the leg in full line x 3 Press five times till the one side of blinking on the screen Legs must short than hypotenuse or there will be err shows on scr...

Страница 11: ...be showed on the screen Area cumulative function Measure the first area as showing in PIC1 Then press button and measure the second area as showing in PIC2 there is a in the left bottom At last press...

Страница 12: ...r4 Err5 Info message Cause Solution Signal is too weak Out of distance measurement range Use the device within the range Chose the surface with stronger reflectance Use the reflecting plate Signal is...

Страница 13: ...Area and Volume measurement function Pythagorean proposition measurement function Add and subtract measurement function Area measurement function Min Max value Self Calibration Laser level Laser type...

Страница 14: ...rosion liquid is never allowed to use for the meter maintenance Laser output window and its focus lens can be maintained according to maintenance procedures for optical device Please check if the acce...

Страница 15: ......

Страница 16: ...Hongkong Sndway Instrument Company Limited Url www sndway com E mail market sndway com...

Отзывы: