background image

LL300S Hands-On Training

January 2015

Содержание LL300S

Страница 1: ...LL300S Hands On Training January 2015 ...

Страница 2: ...LL300S Controls Battery Status LED Level LED Manual Mode Standby Button Power Button HI Manual Standby LED Slope Buttons ...

Страница 3: ...RC402N Radio Remote Control Left Right Buttons Menu button Manual Mode Standby Button Up Down Buttons LCD Display On Off Button RC402N Battery status LED Enter button Hand loop ...

Страница 4: ...LL300S Peripherals Rubber Feet Serial Number 5 8 x 11 Beam Exit Metal Sunshade Sighting Guides ...

Страница 5: ...LL300S Peripherals Plastic Feet Rubber Foot Laser Safety Labels 5 8 x 11 ...

Страница 6: ...Installing The Batteries Enter the battery housing by turning the battery door knob counterclockwise ...

Страница 7: ...battery Pack It is keyed to prevent mis insertion The cage prevents accidental charging of Alkaline batteries Do not try to open the cage for exchanging the rechargeable batteries Worldwide charger has plugs for US EU AU and GB Recharge time is about 10 hours ...

Страница 8: ...gram on the battery door Do NOT try to install Alkaline batteries in the rechargeable battery Pack Special screws are used to ensure only autorized service centers can replace the batteries Trying to open the cage will destroy the cage lid holders New warning label at the battery cage ...

Страница 9: ...e All LEDs are turned on for 3 seconds diagnostic mode Green LED flashes during self leveling When leveled the green LED lights solid for the first five minutes then flashes every 4 seconds indicating the laser remains level and the HI alert has been activated To turn the unit off press and hold the power button for 2 seconds ...

Страница 10: ... turned off while the HI alert is still active Press and hold the Manual button at the laser or remote control for 3 seconds activates the Standby mode The HI MAN LED at the laser flashes red every 5 seconds while the RC402N display shows Standby To deactivate Standby mode and restore full operation of the laser press and hold the Manual button at the laser or remote control again for 3 seconds ...

Страница 11: ...e transmitter or remote control Manual LED will flash red Change the slope using the arrow buttons at the laser Y axis or remote control both axes The remote s left right buttons can be used for vertical fine line adjustments To resume automatic self leveling mode press manual button twice Note When set up vertically the unit switches always automatically into manual mode ...

Страница 12: ...t the laser or remote twice The red and green LED s will flash simultaneously once a second To resume automatic self leveling mode press the manual mode button transmitter or remote again When in Slope Mode the X axis will self level to maintain a consistent elevation of the sloped reference plane ...

Страница 13: ...ing Single Slope Mode 1 Set up the laser at the first elevation point and align it to the second desired slope elevation hub using the sighting guides on the sunshade 2 Check the laser beam elevation close to the laser ...

Страница 14: ...once a second 4 Set the grade rod with the receiver attached to it on the second desired slope elevation hub NOTE DO NOT change the receiver position at the rod In order to keep it as a single person operation when working without a remote control it s recommended to use a bipod Grade Matching using Single Slope Mode 1 Hz ...

Страница 15: ...ching using Single Slope Mode 5 Press the up and down arrow buttons at the laser or at the remote control until you get an on grade reading on the receiver 6 Check the elevations along the direction of the slope ...

Страница 16: ... To activate the mask mode on the or Y axis press the Up or Down arrow button at the laser or remote control then within 1 second press and release the Manual button The Mask mode for the or X axis can only be activated deactivated by pressing the Right or Left arrow button in sequence with the Manual button at the optional remote control Note The unit always powers up with the mask mode deactivat...

Страница 17: ...ates deactivates the manual mode single slope mode press and hold for 3 seconds activates deactivates the Standby mode Up Down Arrow Buttons Left Right Arrow Buttons ON OFF button press for 1 second to turn on the unit press and hold for 2 seconds to turn off the unit RC402N Battery Status LED red Battery status laser Mask mode indication HI Alert activated The remote control mirrors the basic fun...

Страница 18: ...e plus and minus diagrams inside the battery housing 3 Close the battery door Push down until it clicks into the locked position Turning On Off the Radio Remote Control Press the power button to turn on the radio remote control To turn off the radio remote control press and hold the power button for 2 seconds Display at RC402N LL300S horizontal setup Display at RC402N LL300S vertical setup ...

Страница 19: ...n and turn on the transmitter The battery LED flashes fast During the next 6 seconds repeat the same steps on the remote control The Laser s red battery LED flashes fast and the remote s display shows Pairing OK for one second and then the same function as the laser is actually working to indicate the transmitter has been matched with the remote control ...

Страница 20: ...ssing the down arrow button once Press and release the button the mask symbol occurs For selecting the side press and release one of the arrow buttons When all areas have been set press button to store the mask sector selection The RC402N display indicates which side of the laser the beam has been electronically turned off ...

Страница 21: ...lay and go to Settings by pressing the down arrow button twice Press and release the button HI Alert will be marked in arrow brackets then press the button again The desired HI alert 5 min Default 30 seconds and HI Off can be selected using the Up Down buttons Press and release button to confirm the selected HI Alert ...

Страница 22: ...essing the down arrow button twice Press and release the button then press the button once Sensitivity will be marked in arrow brackets Press and release the button to open the Sensitivity submenu The desired Sensitivity Low Middle Default and High can be selected using the Up Down buttons Press and release button to confirm the selected Sensitivity ...

Страница 23: ...sing the down arrow button twice Press and release the button then press the button twice Language will be marked in arrow brackets Press and release the button to open the Language submenu Use Up Down buttons to select the required local language EN DE IT FR ES PT NL DA NO SV FI PL TR CZ Press and release button to confirm the selected Language ...