BTP-M300 Programming Manual
- 29 -
XOFF
[Function]
Data return is disabled.
[Format]
ASCII
XOFF
Hex
13
Decimal 19
[Notes]
• This command is effective when the interface is serial and flow control is software
handshake.
• Data return is forbidden.
• This command disables printer to return data. At prohibitive stage, the data to be
returned are thrown away.
ESC 2
[Function]
Select 1/6 inch (about 4.23mm) as line spacing.
[Format]
ASCII
ESC 2
Hex
1B
32
Decimal 27
50
[Relative]
ESC 3
ESC 3 n
[Function]
Set line spacing to n × 0.176 mm
[Format]
ASCII
ESC 3
n
Hex
1B
33 n
Decimal 27
51
n
[Range]
0
≤
n
≤
255
[Default]
n=24
[Relative]
ESC 2
ESC <
[Function]
Move the print head to the original position
[Format]
ASCII
ESC <
Hex
1B
3C
Decimal 27
60
[Notes]
Move the print head to the original position.
ESC = n
[Function]
Select
printer
[Format]
ASCII
ESC =
n
Hex
1B
3D
n
Decimal 27
61
n
[Range]
1
≤
n
≤
3
[Default]
n = 1
[Notes]
Select printer to receive the data sent by the host computer, using n as follows:
Содержание BTP-M300