20
Section 4 - REPAIR & ADJUSTMENTS
4.5.4. BATTERY
TESTING
Battery Condition Chart
State of Charge
Syringe Hydrometer
Digital Voltmeter
Five Ball Hydrometer
100% Charged w/ Sulfate Stop
1.280
12.80v
Five Balls Floating
100% Charged
1.265
12.60v
Four Balls Floating
75% Charged
1.210
12.40v
Three Balls Floating
50% Charged
1.160
12.10v
Two Balls Floating
25% Charged
1.120
11.90v
One Ball Floating
0% Charged
Less than 1.100
Less than 11.80v
Zero Balls Floating