- The start button produces no effect.
START SIGNAL TEST.
Correct?
Control board (40), connector J5, terminals 3 and 4 = approximately 0 Vac, with start button
pressed (26 Vac with button released ).
YES
NO
♦
Check the wiring between J5 control board (40) and TP2 and TP3 on connector
board (49).
♦
Make sure the torch connector is properly connected on CN1 connector board
(49), and that the START button on the torch is working properly.
♦
With power source off, temporarily disconnect the connector J5 from control
board (40), and check the resistance between terminals 3 and 4 of J5 control board
(40). Correct values = junction of a diode in both directions (for this measurement
the voltage at the diode junction can be between 0.5 and 1 Vdc, approximately). If
incorrect replace control board (40).
♦
Check the power supply to the control board (40), performing the CONTROL
BOARD (40) POWER SUPPLY TEST in par. 3.3.1 if necessary.
♦
Make sure the tracks of the printed circuit on connector board (49) match,
checking the continuity of the following connections:
−
Conn. CN1, terminal 1 - TP2;
−
Conn. CN1, terminal 2 - TP3;
−
Conn. CN1, terminal 3 -TP4;
−
Conn. CN1, terminal 4 - TP5;
−
Conn. CN1, terminal 5 - TP6.
If you find broken tracks restore them, or replace connector board (49).
♦
Replace connector (49) and/or control (40) boards.
♦
Replace control board (40).
3.302.221
15/01/07