CEBORA S.p.A.
12
3.3.2
- Power source powered, control panel on, fan (45) stopped.
FAN (45) TEST.
Correct?
Fan (45) terminals on terminal board (52) = 230 Vac, with switch (15) closed and mains
voltage both at 208 or 230 Vac.
NO
YES
♦
Make sure that there are no mechanical impediments blocking the fan (45).
♦
With the power source off, temporarily disconnect, the fan (45) terminals from
terminal board (52) and check resistance between terminals of fan (45). Correct
value = 50 ohm approximately. If incorrect replace the fan (45).
♦
Replace the fan (45).
♦
Check the wiring between switch (15), terminal board (52), the wired bridges on terminal
board (52) and fan (45) terminals.
♦
Check connections between transformer (46) primary winding and switch (15).
3.302.221
15/01/07