background image

Snap-on Tools Corporation  Kenosha, WI  53141-1410

3

4. Plug the TIG torch switch cord

into the Control receptacle
(OUTPUT).

5. Attach the gas regulator/flow-

meter to a cylinder of 100% pure
Argon gas.

6. Attach the TIG torch gas hose

directly to the gas regulator/
flowmeter.

7. Turn on the gas cylinder and open

the TIG torch gas valve to purge
the system of impurities in the
gas line. Purge for one minute to
ensure porosity free welds.

INSTALLATION (Cont.)

FLEX-TIG INSTALLATION

1. Disconnect the Feeder control

cable assembly from the front of
the power source.

2. Plug the TIG torch power cable

into "WORK" (-) terminal.

3. Plug the Work cable into "TORCH"

(+) terminal. With the TIG torch
and Work cable connected in this
manner, straight polarity(DCSP)
current is available as required
for TIG welding.

SWITCH CORD

TO WELDER

CONTROL

RECEPTACLE

TIG

TORCH

GAS HOSE

TO REGULATOR/

FLOWMETER

100%

ARGON

GAS

CONTROL

RECEPTACLE

(OUTPUT)

POWER CABLE TO

WORK (-) TERMINAL

(WORK CABLE PLUGS INTO

POSITIVE (+) TERMINAL)

LOCKING

SWITCH

FIG. 3. FLEX-TIG TYPICAL INSTALLATION PROCEDURES

YOU ARE NOW READY TO TIG WELD!

GAS

VALVE

Содержание FLEX-TIG

Страница 1: ...EN INERT GAS T I G WELDING ONSTEEL STAINLESSSTEEL CHROME MOLY COP PER AND CAST IRON THIS T I G WELDING PACKAGE WILL NOT WELD ALUMINUM OWNERS MANUAL FLEX TIG FOR TECH SERVICE CALL TOLL FREE 1 800 232 9353 FORM WC5229 Rev 1 99 INSTALLATION OPERATION REPLACEMENT PARTS ...

Страница 2: ...THIS LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED THE MANUFACTURER SHALL NOT BE LIABLE FOR ANY INJURY TO PERSONS INCLUDING DEATH OR LOSS OR DAMAGE TO ANY PROPERTY DIRECT OR CON SEQUENTIAL INCLUDING BUT NOT LIMITED TO LOSS OF USE ARISING OUT OF THE USE OR THE INABILITY TO USE THE PRODUCT THE USER AS SUMES ALL RISK AND LIABILITY WHATSOEVER IN CONNECTION WITH THE USE OF THE ...

Страница 3: ...8 gauge thru 3 32 The higher MIG voltages are for use on material from 3 32 thru 1 4 The FLEX TIG consists of a 200 amp gas cooled torch with built in gas control valve remote On Off switch 12 1 2 or 25 foot cable assembly and the required consum able parts NOTE THIS T I G WELDING PACKAGE WILL NOT WELD ALUMINUM CONTENTS 1 TIG Torch with built in valve 1 Locking Electric Switch with cord installed ...

Страница 4: ...cup 1 8 9 Screw Backcap into torch head tighten firmly SPECIFICATIONS PART NUMBER FLEX TIG 12 FLEX TIG 25 TORCH RATING 200 Amps DCSP DUTY CYCLE 100 reduce duty cycle when operating over 200 amps COOLING METHOD Gas 100 Argon SHIELDING GAS CONTROL METHOD Gas Valve on Torch WELD CURRENT ON OFF CONTROL Locking Switch on Torch FIG 1 TUNGSTEN PREPARATION STABLE ARC STRAIGHT GROUND IDEAL VIEW FLAT the Di...

Страница 5: ...ATION Cont FLEX TIG INSTALLATION 1 Disconnect the Feeder control cable assembly from the front of the power source 2 Plug the TIG torch power cable into WORK terminal 3 Plug the Work cable into TORCH terminal With the TIG torch and Work cable connected in this manner straight polarity DCSP current is available as required for TIG welding SWITCH CORD TO WELDER CONTROL RECEPTACLE TIG TORCH GAS HOSE ...

Страница 6: ...200 AMPS A 100 DUTY CYCLE OPERATION ABOVE MIG VOLTAGE SETTING 3 COULD RESULT IN PERMANENT DAMAGE TO THE TORCH HEAD AND CABLES 5 Depress the TIG torch switch and lock On scratch or touch tungsten to the work and draw back to establish an arc CAUTION Continual sticking of the tungsten electrode to the work surface can cause severe damage to the MIG welding machine 6 Once arc is established hold and ...

Страница 7: ...16 COLLET BODY 1 16 3CB332 COLLET BODY 3 32 3HF FITTING GAS HOSE 412CN 200A POWER CABLE only with fittings 12 1 2 210HE SN 6191B 3HF SN 520 412CN 200A 425CN 200A 412PC 200A 425PC 200A VK PART NO DESCRIPTION 425CN 200A POWER CABLE only with fittings 25 412PC 200A POWER CABLE AND HOSE ASSEMBLY 12 1 2 425PC 200A POWER CABLE AND HOSE ASSEMBLY 25 CK210V TORCH BODY only with valve assembly heatshield SC...

Страница 8: ...6 Snap on Tools Corporation Kenosha WI 53141 1410 NOTES ...

Отзывы: